Home  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2007R

Fully Safety jaw,Ergonomic over-molded body gives convenient one-hand operationLarge easy-to-read display with 0.1A resolution,Accurate reading with True RMS 600/1000A auto-ranging.
 

KEW 1020R

Large display with 6000 counts and Backlight, True-RMS,MIN/MAX function,Rugged and reliable,Clamp sensor mode,IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V.

KEW 2510

Measures 4 to 20 mA instrumentation and process signals without breaking the loop,Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding.
 

KEW 1062

High Accuracy, High Performance and Reliable Measurements,Safety design for industrial use,Reliable support for data management.
 
  • Tab 1

    KEW 3128 High Voltage Insulation Testers

    Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions,Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc,6 ranges: 500V, 1000V, 2500V,5000V,10000V,12000V,Fine adjustment of voltage setting at each range is also possible. Learn More...

     
  • Tab 2

    KEW 6315 Power Quality Analyzer

    Simultaneous Power & Power quality measurements,Helpful support functions,Measurement with high accuracy,Remote monitoring on PC and Android device,Various Clamp Current Sensors,Energy consumption check on site,IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V. Learn More...

     
  • Tab 3

    KEW 6016 Multi Function Testers

    Continuity Measurement,Insulation Measurement,Loop Impedance Measurement,PSC / PFC Measurement,RCD Measurement,Earth Measurement,Phase rotation,Voltage Measurement. Learn More...

     

Jual Digital Insulation / Continuity Testers KEW 3021

 

Digital Insulation / Continuity Testers

KEW 3021

KEW 3021
CE
AutoDischarge
 
• 3 functions in one unit, insulation test with 4 voltage ranges,
 continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
 on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
  • 125V 250V 500V 1000V DCACV Resistance Continuitybuzzer Backlight AutoPowerOff
 

Insulation resistance

Test voltage 125/250/500/1000V
Measuring range
(Auto range)
4.000/40.00/200.0MΩ(125V)
4.000/40.00/400.0/2000MΩ(250/500/1000V)
First effective measuring range 0.1 - 20MΩ (125V)
0.1 - 40MΩ (250V)
0.1 - 200MΩ (500V)
0.1 - 1000MΩ (1000V)
Mid-scale value 5MΩ (125/250V)
50MΩ (500V/1000V)
Accuracy ±2%rdg±6dgt
Second effective measuring range lower 0 - 0.099MΩ
Second effective measuring range upper 20.01 - 200.0MΩ (125V)
40.01 - 2000MΩ (250V)
200.1 - 2000MΩ (500V)
1001 - 2000MΩ (1000V)
Accuracy ±5%rdg±6dgt
Rated current DC 1 - 1.2mA
Output short circuit current 1.5mA max

Ω/Continuity

Auto range 40.00/400.0Ω
Accuracy ±2%rdg±8dgt
Output voltage on open circuit 5V±20%
Output short circuit current DC 220±20mA
Fuse Quick acting ceramic fuse 0.5A/600V (Ø6.35×32mm)

AC Voltage

AC voltage range AC 20 - 600V (50/60Hz)
DC -20 - -600V/+20 - +600V
Accuracy ±3%rdg±6dgt

General

Applicable standards IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC),
IEC 60529 (IP40)
Power source R6 × 6 or LR6 × 6
Dimensions / Weight 105(L) × 158(W) × 70(D)mm / 600g approx.
Included Accessories 7150A (Remote control switch set),
9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual
Optional Accessories 7115 (Extension Probe), 8016 (Hook type prod),
8923 (Fuse [0.5A/600V]), 9089 (Carrying Case)

 

Jual Digital Insulation / Continuity Testers MODEL 3007A

 

Digital Insulation / Continuity Testers

MODEL 3007A

MODEL 3007A
CE
AutoDischarge
 
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Trac-Lok mode to conserve battery life on insulation and continuity tests.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• Backlight function to view the test results in dimly lit areas.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
  • ACV Resistance Continuitybuzzer Backlight AutoPowerOff 250V 500V 1000V
 

Insulation Resistance

Test voltage 250V/500V/1000V
Measuring ranges
(Mid-scale value)
20MΩ/200MΩ/2000MΩ
Output voltage on open circuit Rated test voltage+20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1.5 mA DC approx.
Accuracy ±1.5%rdg±5dgt (20MΩ/200MΩ)
±10%rdg±3dgt (2000MΩ)

Continuity Test

Measuring ranges
(Mid-scale value)
20Ω/200Ω/2000Ω
Output voltage on open circuit 7 - 12V DC
Measuring current 200mA DC min.
Accuracy ±1.5%rdg±5dgt (20Ω)
±1.5%rdg±3dgt (200Ω/2000Ω)

AC Voltage

AC voltage range 0-600V AC
Accuracy ±5%rdg±3dgt

General

Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Power source R6 (AA) (1.5V) × 8
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 990g approx
Included Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 8
Shoulder Strap
Instruction Manual

 

Jual Digital Insulation / Continuity Testers MODEL 3005A

 

Digital Insulation / Continuity Testers

MODEL 3005A

MODEL 3005A
CE
AutoDischarge
 
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
  • ACV Resistance Continuitybuzzer AutoPowerOff 250V 500V 1000V
 

Insulation Resistance

Test voltage 250V/500V/1000V
Measuring ranges
(Mid-scale value)
20MΩ/200MΩ/2000MΩ
Output voltage on open circuit Rated test voltage+20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1.5 mA DC approx.
Accuracy ±1.5%rdg±5dgt (20MΩ/200MΩ)
±10%rdg±3dgt (2000MΩ)

Continuity Test

Measuring ranges
(Mid-scale value)
20Ω/200Ω/2000Ω
Output voltage on open circuit 7 - 12V DC
Measuring current 200mA DC min.
Accuracy ±1.5%rdg±5dgt (20Ω)
±1.5%rdg±3dgt (200Ω/2000Ω)

AC Voltage

AC voltage range 0 - 600V AC
Accuracy ±5%rdg±3dgt

General

Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Power source R6 (AA) (1.5V) × 8
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 970g approx
Included Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 8, Shoulder Strap
Instruction Manual

 

Silahkan hubungi kami segera untuk pemesanan, di nomor-nomor sebagai berikut : 021-29478974 , 081289462227 , email : sales@kyoritsuindonesia.com

KYORITSU News

Clamp Sensors

Flexible Clamp Sensor KEW 8130 • Ø110mm • Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at...

Others

Illuminometer MODEL 5201 • Digital Illuminometer • Model 5201 is a highly portable and compact digital illuminometer for measuring illuminance from 0.1 to 19,990 Lux, with auto...

KT 171

Jual Kyoritsu Voltage Testers KT 171   Voltage Testers KT 171   • AC and DC voltage tests up to 690V with LEDs and LCD • Comply with the...

KT 170

Jual Kyoritsu Voltage Testers KT 170   Voltage Testers KT 170     • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

Voltage Testers

Kyoritsu Indonesia - Jual Kyoritsu Voltage Testers Voltage Testers KT 170 • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

KEW 8031F

Jual Kyoritsu Phase Indicators KEW 8031F   Phase Indicators KEW 8031F   • KEW8031F is designed to check phase sequence. Lamps provided on the unit will also tell you if...

MODEL 8031

Jual Kyoritsu Phase Indicators MODEL 8031   Phase Indicators MODEL 8031   • Digital Phase Indicator with open phase checker. • Phase indicator designed to check the presence of open...

MODEL 8030

Jual Kyoritsu Phase Indicators MODEL 8030   Phase Indicators MODEL 8030   • Digital Phase Indicator with open phase checker • Phase indicator designed to check the presence of open...

KEW 8035

Jual Kyoritsu Non-Contact Safety Phase Indicator KEW 8035   Non-Contact Safety Phase Indicator KEW 8035   • New technology permits safe testing, without the need of direct contact between probes...

Phase Indicator

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator Non-Contact Safety Phase Indicator KEW 8035 Safe Testing without direct contact with live wires!! • New technology permits safe testing, without...

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A   Portable Appliance Testers KEW 6201A   The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of...

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140   LOOP/PFC/PSC Testers KEW 4140   • Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. •...

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A   LOOP/PFC/PSC Testers MODEL 4118A     • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status....

KEW 5410

Jual RCD Testers KEW 5410   RCD Testers KEW 5410   • Measurement of RCD trip time  Conducting testing of rated residual non-operating currents at  × 1/2 Range, measuring RCD...

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A   RCD Testers MODEL 5406A   • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. •...

KYORITSU Video

Guests Online

We have 11 guests and no members online

Quality Control Concept

Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter. Learn More...