Home  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2007R

Fully Safety jaw,Ergonomic over-molded body gives convenient one-hand operationLarge easy-to-read display with 0.1A resolution,Accurate reading with True RMS 600/1000A auto-ranging.
 

KEW 1020R

Large display with 6000 counts and Backlight, True-RMS,MIN/MAX function,Rugged and reliable,Clamp sensor mode,IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V.

KEW 2510

Measures 4 to 20 mA instrumentation and process signals without breaking the loop,Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding.
 

KEW 1062

High Accuracy, High Performance and Reliable Measurements,Safety design for industrial use,Reliable support for data management.
 
  • Tab 1

    KEW 3128 High Voltage Insulation Testers

    Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions,Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc,6 ranges: 500V, 1000V, 2500V,5000V,10000V,12000V,Fine adjustment of voltage setting at each range is also possible. Learn More...

     
  • Tab 2

    KEW 6315 Power Quality Analyzer

    Simultaneous Power & Power quality measurements,Helpful support functions,Measurement with high accuracy,Remote monitoring on PC and Android device,Various Clamp Current Sensors,Energy consumption check on site,IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V. Learn More...

     
  • Tab 3

    KEW 6016 Multi Function Testers

    Continuity Measurement,Insulation Measurement,Loop Impedance Measurement,PSC / PFC Measurement,RCD Measurement,Earth Measurement,Phase rotation,Voltage Measurement. Learn More...

     

Digital Multimeters

KEW 1052

 

KEW 1052
CE
 
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• True-RMS or MEAN value detection mode can be selected
• Low-pass filter for motor drive measurements
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC

Reliable support for data management
• Large data internal memory 1,600 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
*MAX 32,767 data can be transferred.

TRUE RMS CAT4 600V DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency Temperature Backlight DATAHOLD MAX/MIN/AVG Relative Filter USB AutoPowerOff

 

 
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency 10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature -50 - 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)

 

Option

 

DescriptionModelSpecification
Crocodile clip test lead 7234 CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor 8115 AC 130A / DC 180A
Clamp sensor 8121 AC 100A
8122 AC 500A
8123 AC 1000A
8146 AC 30A
8147 AC 70A
8148 AC 100A
Banana Ø4mm Adjuster Plug 7146 length:190mm
USB Communication set 8241 USB adaptor + USB cable + DMM Software
DMM Printer full set 8249 8243+8246+8248
  Printer Communication set 8243 Printer Adapter + RS232 cable
Printer 8246 Printer + Thermal paper (1 roll)
AC adapter for printer [EU] 8248A AC230V±10%
Thermal paper for printer 8247 10 rolls
Carrying case 9154 for the main unit with testi leads and communication cable

 

Thermocouple Type K Specification

 

DescriptionModelSpecification
Temperature probes 8405 Max. 500ºC
(Surface type, Point material: Ceramic)
8406 Max. 500ºC (Surface type)
8407 Max. 700ºC (Liquid, Semi-solid)
8408 Max. 600ºC (Air, Gas)

 

Digital Multimeters

KEW 1051

 

KEW 1051
CE
 
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• Low-pass filter for motor drive measurements
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC

TRUE RMS CAT4 600V DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency Temperature Backlight DATAHOLD Relative Filter AutoPowerOff

 

 
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency 10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature -50 - 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Zero Adjustment (Capacitor, Resistance), LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Display 6,000 counts
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)

 

Option

 

DescriptionModelSpecification
Crocodile clip test lead 7234 CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor 8115 AC 130A / DC 180A
Clamp sensor 8121 AC 100A
8122 AC 500A
8123 AC 1000A
8146 AC 30A
8147 AC 70A
8148 AC 100A
Banana Ø4mm Adjuster Plug 7146 length:190mm
Carrying case 9154 for the main unit with testi leads and communication cable

 

Thermocouple Type K Specification

 

DescriptionModelSpecification
Temperature probes 8405 Max. 500ºC
(Surface type, Point material: Ceramic)
8406 Max. 500ºC (Surface type)
8407 Max. 700ºC (Liquid, Semi-solid)
8408 Max. 600ºC (Air, Gas)

 

Kyoritsu Indonesia - Jual Digital Multimeters KEW 1030

KEW 1030

 

KEW 1030
CE
 
• Compact in Size, Light in Weight and Simple in Use.
• Double moulding provides comfortable and good feeling in hand.
• Penlight illuminates brightly the point to be measured, even in dark place.
• Backlight LCD is highly visible, even in darkness.
• Unique wrapping mechanism for test lead in the rear side compartment.
• Unique protection mechanism for the test prod for safety.
• All ranges including Ohm range are protected against overload voltage of 600V.

DCACV Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Backlight DATAHOLD Relative AutoPowerOff

 

■Long life LED light is of good use in dark place ■Protection cover prevents unforeseen accident
■Wrapping mechanism for test lead in rear side compartment

* Length of test lead is adjustable in 3 steps, ie, 60cm, 40cm and 20cm.

 

DC V 400m/4/40/400/600V (5 Range auto)
±0.8%rdg ±5dgt(400mV - 400V)
±1.0%rdg ±5dgt(600V)
AC V 4/40/400/600V (4 Range auto)
±1.3%rdg ±5dgt (4/40V) (50/60Hz)
±1.6%rdg ±5dgt (400/600V) (50/60Hz)
Ω 400/4k/40k/400k/4M/40MΩ (6 Range auto)
±1.0%rdg ±5dgt (400Ω - 4MΩ)
±2.5%rdg ±5dgt (40MΩ)
Continuity buzzer Buzzer sounds when resistance is 120Ω or less.
Diode test Test voltage approx. 0.3 - 1.5V
Capacitance 50n/500n/5µ/50µ/100µF (5 Range auto)
±3.5%rdg ±10dgt (50nF)
±3.5%rdg ±5dgt (500n - 50µF)
±4.5%rdg ±5dgt (100µF)
Frequency 5/50/500/5k/50k/200kHz
±0.1%rdg ±5dgt (Measurable input: 1.5Vrms or more)
DUTY 0.1 - 99.9%
±2.5%rdg ±5dgt (Pulse width / Pulse cycle)
Measurement functions The measured value can be hold by pressing Data hold button
Other functions When the battery voltage drops to 2.4V±0.2V or less
Built-in
Applicable standards IEC 61010-1: 2001 CAT III 600V
IEC 61010-031
IEC 61326-1
Power source Button type battery LR44 (SR44)1.5V × 2
Dimensions 190(L) × 39(W) × 31(D)mm
Weight Approx. 100g (including batteries
Included Accessories Carrying case, LR44 (1.5V) × 2, Instruction manual

 

Silahkan hubungi kami segera untuk pemesanan, di nomor-nomor sebagai berikut : 021-29478974 , 081289462227 , email : sales@kyoritsuindonesia.com

KYORITSU News

Clamp Sensors

Flexible Clamp Sensor KEW 8130 • Ø110mm • Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at...

Others

Illuminometer MODEL 5201 • Digital Illuminometer • Model 5201 is a highly portable and compact digital illuminometer for measuring illuminance from 0.1 to 19,990 Lux, with auto...

KT 171

Jual Kyoritsu Voltage Testers KT 171   Voltage Testers KT 171   • AC and DC voltage tests up to 690V with LEDs and LCD • Comply with the...

KT 170

Jual Kyoritsu Voltage Testers KT 170   Voltage Testers KT 170     • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

Voltage Testers

Kyoritsu Indonesia - Jual Kyoritsu Voltage Testers Voltage Testers KT 170 • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

KEW 8031F

Jual Kyoritsu Phase Indicators KEW 8031F   Phase Indicators KEW 8031F   • KEW8031F is designed to check phase sequence. Lamps provided on the unit will also tell you if...

MODEL 8031

Jual Kyoritsu Phase Indicators MODEL 8031   Phase Indicators MODEL 8031   • Digital Phase Indicator with open phase checker. • Phase indicator designed to check the presence of open...

MODEL 8030

Jual Kyoritsu Phase Indicators MODEL 8030   Phase Indicators MODEL 8030   • Digital Phase Indicator with open phase checker • Phase indicator designed to check the presence of open...

KEW 8035

Jual Kyoritsu Non-Contact Safety Phase Indicator KEW 8035   Non-Contact Safety Phase Indicator KEW 8035   • New technology permits safe testing, without the need of direct contact between probes...

Phase Indicator

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator Non-Contact Safety Phase Indicator KEW 8035 Safe Testing without direct contact with live wires!! • New technology permits safe testing, without...

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A   Portable Appliance Testers KEW 6201A   The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of...

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140   LOOP/PFC/PSC Testers KEW 4140   • Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. •...

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A   LOOP/PFC/PSC Testers MODEL 4118A     • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status....

KEW 5410

Jual RCD Testers KEW 5410   RCD Testers KEW 5410   • Measurement of RCD trip time  Conducting testing of rated residual non-operating currents at  × 1/2 Range, measuring RCD...

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A   RCD Testers MODEL 5406A   • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. •...

KYORITSU Video

Guests Online

We have 54 guests and no members online

Quality Control Concept

Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter. Learn More...