Home  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2007R

Fully Safety jaw,Ergonomic over-molded body gives convenient one-hand operationLarge easy-to-read display with 0.1A resolution,Accurate reading with True RMS 600/1000A auto-ranging.
 

KEW 1020R

Large display with 6000 counts and Backlight, True-RMS,MIN/MAX function,Rugged and reliable,Clamp sensor mode,IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V.

KEW 2510

Measures 4 to 20 mA instrumentation and process signals without breaking the loop,Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding.
 

KEW 1062

High Accuracy, High Performance and Reliable Measurements,Safety design for industrial use,Reliable support for data management.
 
  • Tab 1

    KEW 3128 High Voltage Insulation Testers

    Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions,Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc,6 ranges: 500V, 1000V, 2500V,5000V,10000V,12000V,Fine adjustment of voltage setting at each range is also possible. Learn More...

     
  • Tab 2

    KEW 6315 Power Quality Analyzer

    Simultaneous Power & Power quality measurements,Helpful support functions,Measurement with high accuracy,Remote monitoring on PC and Android device,Various Clamp Current Sensors,Energy consumption check on site,IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V. Learn More...

     
  • Tab 3

    KEW 6016 Multi Function Testers

    Continuity Measurement,Insulation Measurement,Loop Impedance Measurement,PSC / PFC Measurement,RCD Measurement,Earth Measurement,Phase rotation,Voltage Measurement. Learn More...

     

Leakage Clamp Meters

MODEL 2412

 

MODEL 2412
 
• Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.
• Resolution 0.01mA.

φ40 MAX500A ACV Resistance OutPut Filter External

 

 

AC A (50/60Hz) 20/200mA/2/20/200/500A
±1.5%rdg±5dgt (20/200mA/2A)
±2%rdg±5dgt (20/200A)
±2.5%rdg±5dgt (500A)
AC A (WIDE) 20/200mA/2/20/200/500A
±1%rdg±3dgt [50/60Hz],
±5%rdg±5dgt [40 - 400Hz] (20/200mA/2A)
±1.5%rdg±3dgt [50/60Hz],
±5%rdg±5dgt [40 - 400Hz] (20/200A)
±2%rdg±3dgt [50/60Hz],
±5%rdg±5dgt [40 - 400Hz] (500A)
AC V 600V
±2%rdg±5dgt (50/60Hz)
±5%rdg±5dgt (40 - 400Hz)
Ω 200Ω ±1.5%rdg±5dgt
Conductor size Ø40mm max.
Frequency response 40 - 400Hz
Effect of external stray magnetic field φ15mm 100A 10mA AC max.
Output Recorder : DC200mV against the maximum value of each range (500A range is 50mV)
Power source 6F22 (9V) × 1 or AC Adaptor
Dimensions 209(L) × 96(W) × 45(D)mm
Weight 450g approx.
Included Accessories 7066A (Test leads)
9169 (Carrying case)
8025 (Plug for output jack)
6F22 × 1
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*
8022 (AC adaptor) (110V)
8023 (AC adaptor) (220V)
7256 (Output cord)

 

Fork Current Tester

MODEL 2300R

 

MODEL 2300R
CE
 
• True RMS reading is an essential feature for accurate measurement.
• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
• Set the DC current range to zero in one touch with the Zero Adjust function.

TRUE RMS φ10 MAX100A DCACA DATAHOLD AutoPowerOff

KEW FORK 2300R can be used in crowded connection boxes, where cables are very short, and space is too limited to clamp cables using with a traditional clamp meter.

 

True RMS (Root Mean Square) Value Measurement

When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc...,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
 The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.

(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)

 

Current measurement AC A 0 to 100.0A ±2.0%rdg±5dgt (50/60Hz)
DC A 0 to ±100.0A ±2.0%rdg±5dgt
Crest factor 2.5
Non contact voltage Detect AC voltage without contacting with socket wire
During voltage detection, "Hi" flashes and a buzzer sounds
Maximum digit 1,049
Conductor size Max Ø10mm
Safety Standard IEC 61010-1 CAT III 300V Pollution degree 2
Power source R03 (AAA) × 2 (Auto power off: approx.10 minutes)
*Continuous measuring time: AC A approx. 46 hours DC A approx. 52 hours
Dimensions 161.3(L) × 40.2(W) × 30.3(D)mm
Weight 110g (with batteries)
Included Accessories 9113 (Carrying Case)
R03 (AAA) × 2
Instruction Manual

 

AC/DC Digital Clamp Meters

KEW 2056R

 

KEW 2056R
CE
 
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.

TRUE RMS CAT4 600V φ40 MAX1000A DCACV DCACA Resistance Continuitybuzzer FrequencyDUTY Diode Capacitance Temperature Backlight DATAHOLD PeakHold10ms MAX/MIN RelativeAutoPowerSave AutoPowerOff

 

 

AC A 0 - 600.0/1000A
±2.0%rdg±5dgt (50/60Hz)
±3.5%rdg±5dgt (40 - 500Hz)
DC A 0 - 600.0/1000A
±1.5%rdg±5dgt
AC V 6/60/600V
Auto Ranging
±1.5%rdg±4dgt (50/60Hz)
±3.5%rdg±5dgt (40 - 400Hz)
DC V 600m/6/60/600V
Auto Ranging
±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt (600 - 6M) / ±5%rdg±8dgt (60M)
Continuity buzzer Buzzer Sounds at 100Ω
Temperature -50ºC - +300ºC (With the use of Temperature probe 8216)
Frequency/DUTY 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9%
Conductor size Ø40mm
Safety Standard IEC 61010-1 CAT IV 600V,
IEC 61010-031,
IEC 61010-2-032,
IEC 61326
Power source R03 (1.5V) (AAA) × 2
Dimensions 254(L) × 82(W) × 36(D)mm
Weight 310g
Included Accessories 7066A (Test leads)
9094 (Carrying case)
Instruction Manual
Optional Accessories 8008 (Multi-Tran)
8216 (Temperature probe)

 

Silahkan hubungi kami segera untuk pemesanan, di nomor-nomor sebagai berikut : 021-29478974 , 081289462227 , email : sales@kyoritsuindonesia.com

KYORITSU News

Clamp Sensors

Flexible Clamp Sensor KEW 8130 • Ø110mm • Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at...

Others

Illuminometer MODEL 5201 • Digital Illuminometer • Model 5201 is a highly portable and compact digital illuminometer for measuring illuminance from 0.1 to 19,990 Lux, with auto...

KT 171

Jual Kyoritsu Voltage Testers KT 171   Voltage Testers KT 171   • AC and DC voltage tests up to 690V with LEDs and LCD • Comply with the...

KT 170

Jual Kyoritsu Voltage Testers KT 170   Voltage Testers KT 170     • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

Voltage Testers

Kyoritsu Indonesia - Jual Kyoritsu Voltage Testers Voltage Testers KT 170 • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

KEW 8031F

Jual Kyoritsu Phase Indicators KEW 8031F   Phase Indicators KEW 8031F   • KEW8031F is designed to check phase sequence. Lamps provided on the unit will also tell you if...

MODEL 8031

Jual Kyoritsu Phase Indicators MODEL 8031   Phase Indicators MODEL 8031   • Digital Phase Indicator with open phase checker. • Phase indicator designed to check the presence of open...

MODEL 8030

Jual Kyoritsu Phase Indicators MODEL 8030   Phase Indicators MODEL 8030   • Digital Phase Indicator with open phase checker • Phase indicator designed to check the presence of open...

KEW 8035

Jual Kyoritsu Non-Contact Safety Phase Indicator KEW 8035   Non-Contact Safety Phase Indicator KEW 8035   • New technology permits safe testing, without the need of direct contact between probes...

Phase Indicator

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator Non-Contact Safety Phase Indicator KEW 8035 Safe Testing without direct contact with live wires!! • New technology permits safe testing, without...

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A   Portable Appliance Testers KEW 6201A   The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of...

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140   LOOP/PFC/PSC Testers KEW 4140   • Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. •...

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A   LOOP/PFC/PSC Testers MODEL 4118A     • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status....

KEW 5410

Jual RCD Testers KEW 5410   RCD Testers KEW 5410   • Measurement of RCD trip time  Conducting testing of rated residual non-operating currents at  × 1/2 Range, measuring RCD...

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A   RCD Testers MODEL 5406A   • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. •...

KYORITSU Video

Guests Online

We have 141 guests and no members online

Quality Control Concept

Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter. Learn More...