Home  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2007R

Fully Safety jaw,Ergonomic over-molded body gives convenient one-hand operationLarge easy-to-read display with 0.1A resolution,Accurate reading with True RMS 600/1000A auto-ranging.
 

KEW 1020R

Large display with 6000 counts and Backlight, True-RMS,MIN/MAX function,Rugged and reliable,Clamp sensor mode,IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V.

KEW 2510

Measures 4 to 20 mA instrumentation and process signals without breaking the loop,Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding.
 

KEW 1062

High Accuracy, High Performance and Reliable Measurements,Safety design for industrial use,Reliable support for data management.
 
  • Tab 1

    KEW 3128 High Voltage Insulation Testers

    Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions,Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc,6 ranges: 500V, 1000V, 2500V,5000V,10000V,12000V,Fine adjustment of voltage setting at each range is also possible. Learn More...

     
  • Tab 2

    KEW 6315 Power Quality Analyzer

    Simultaneous Power & Power quality measurements,Helpful support functions,Measurement with high accuracy,Remote monitoring on PC and Android device,Various Clamp Current Sensors,Energy consumption check on site,IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V. Learn More...

     
  • Tab 3

    KEW 6016 Multi Function Testers

    Continuity Measurement,Insulation Measurement,Loop Impedance Measurement,PSC / PFC Measurement,RCD Measurement,Earth Measurement,Phase rotation,Voltage Measurement. Learn More...

     

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator

Non-Contact Safety Phase Indicator

  • KEW 8035

    KEW 8035

    Safe Testing without direct contact with live wires!!
    • New technology permits safe testing, without the need of direct contact between probes and live wires.
    • The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm.
    • Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.

      <li><img src="http://www.kew-ltd.co.jp/files/mark/cat4-600v.png" border="0" alt="CAT4 600V" height="31" />

Phase Indicators

  • MODEL 8030

    MODEL 8030

    • Digital Phase Indicator with open phase checker.
    • Phase indicator designed to check the presence of open phase and also the phase sequence by LED and buzzer at the same time.
    • Small, lightweight, and portable.

    • MODEL 8031

      MODEL 8031

      • Digital Phase Indicator with open phase checker.
      • Phase indicator designed to check the presence of open phase and also the phase
       sequence by LED and buzzer at the same time.
      •Small, lightweight, and portable.

      • KEW 8031F

        KEW 8031F

        • KEW8031F is designed to check phase sequence.
        Lamps provided on the unit will also tell you if a phase is open.
        • Can check a wide range of 3-phase power source from 100V to 600V.
        Sealed against dust, the unit ensures trouble-free performance.
        • Small, Lightweight and portable.
        Designed for maximum ease of operation and ruggedness.
        • No exposed metal parts, Safety features are incorporated including the instant push button switch operation.

Jual Kyoritsu Portable Appliance Tester KEW 6201A

 

Portable Appliance Testers

KEW 6201A

KEW 6201A
CE
 
The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage.
Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.

This instrument is suitable for performing tests as required by the following standards.
AS/NZS 3760 In-service safety inspection and testing of electrical equipment.

Test Function
FunctionTests of contents
Test ⅠClass Protective conductor resistance
Insulation (250V or 500V)
Test ⅠSELECT Switch + Class Protective conductor resistance
Leakage Current test
TestⅡClass Insulation (250V or 500V)
TestⅡSELECT Switch + Class Leakage Current test
Extension Leads test Protective conductor resistance
Insulation P/N-PE
Polarity
SELECT Switch + Extension Leads test Protective conductor resistance
Leakage Current test
Leakage Current Test Leakage current measurement 

RPE 20Ω Protective Conductor Resistance Test

Measuring range  0 - 15.00Ω 
Resolution of measurement 10mΩ
Open circuit voltage < AC 12V
Measuring current 10A AC nominal value
Accuracy ±3%rdg±5dgt

RINS 200MΩ Insulation Resistance

Rating 250V/20MΩ 500V/20MΩ
Measuring range 0 - 19.99Ω
Resolution of measurement 10kΩ
Output voltage 250V DC (+20%/-10%) @1MΩ 500V DC (+20%/-10%) @1MΩ
Short circuit current 2.5mA DC or less
Accuracy ±2%rdg±3dgt

Leakage Current Test

Measuring range AC 0.1 - 19.99mA
Resolution of measurement 0.01mA
Examination time Max 15 seconds
Accuracy ±3%rdg±5dgt

AC VOLT Mains Voltage Check

Measuring range 207 - 264V
Resolution of measurement 1V
Accuracy ±2%rdg±3dgt

General

Supply voltage 240V±10%
Frequency 50Hz±1%
Applicable standards IEC 61010-1 CAT III 300V Pollution Degree2
IEC 61326-1 (EMC)
Dimensions 167(L) × 185 (W) × 89 (D) mm
Weight 1.2kg (only the instrument body)
Included Accessories 7123 (Power cord [AU])
7129A (Test leads with alligator clip)
7161A (Flat test prod [black])
7140 (Adapter for exntesion cord)
9147 (Cord case)
9121 (Shoulder strap)
Instruction manual
Optional Accessories 7121B (Distribution board test leads)

 

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140

 

LOOP/PFC/PSC Testers

KEW 4140

KEW 4140
CE ATT
 
• Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above.
• Dual Display allows simultaneous measurements like Loop & PFC/PSC.
• Two wire connection for Loop L-L, L-N and PSC testing is possible.
• Phase rotation, Voltage and Frequency measurements.
• Lock-down test button for 'hands free' testing with auto-start operation.
• Display and front panel keyboards with Backlight to be visible in dark places.
• Water and Dust proof (IP54)
 

Loop Impedance

Function L-PE ATT OFF L-PE ATT ON L-N / L-L
Rated Voltage 230V (50/60Hz) L-N: 230V (50/60Hz)
L-L: 400V (50/60Hz)
Operating Voltage 100 - 280V (45 - 65Hz) 100 - 500V (45 - 65Hz)
Range (Auto-Ranging) 20/200/2000Ω 20/200/2000Ω
(L-N<20Ω)
20Ω
Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V 20Ω: 6A/40ms
200Ω: 2A/20ms
2000Ω: 15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx.5s
20Ω: 6A/20ms
Accuracy ±3%rdg±4dgt (*1) ±3%rdg±6dgt (*1) L-N: ±3%rdg±4dgt
L-L: ±3%rdg±8dgt

PFC (L-PE) / PSC (L-N / L-L) (*2)

Function PFC PFC (ATT) PSC
Rated Voltage 230V (50/60Hz) L-N: 230V (50/60Hz)
L-L: 400V (50/60Hz)
Operating Voltage 100 - 280V (45 - 65Hz) 100 - 500V (45 - 65Hz)
Range (Auto-Ranging) 2000A/20kA 2000A/20kA (L-N<20Ω) 2000A/20kA
Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V 20Ω: 6A/40ms
200Ω: 2A/20ms
2000Ω: 15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx.5s
20Ω: 6A/20ms

Phase Rotation

Operating Voltage 50 - 500V, 45 - 65Hz
Remarks Correct phase sequence: displayed "1.2.3" and  mark
Reversed phase sequence: displayed "3.2.1" and  mark

Volts

Function Volts Frequency
Measuring range 0 - 500V 45 - 65Hz
Accuracy ±2%rdg±4dgt ±0.5%rdg±2dgt

 

Applicable standards IEC 61010-1 CAT III 300V (500V L to L),
IEC 61010-031, IEC 61557-1, 3, 7, 10,
IEC 60529 (IP54), IEC 61326 (EMC)
Power source 1.5V AA batteries × 6 *Use of alkaline batteries (LR6) is recommended.
Dimensions 84 (L) × 184 (W) × 133 (D) mm
Weight 860g (including batteries)
Included Accessories Main cord (*3)
Distribution board test lead (*4)
9155 (Shoulder strap)
9156 (Soft case)
LR6 (Battery) × 6, Instruction manual

 

Silahkan hubungi kami segera untuk pemesanan, di nomor-nomor sebagai berikut : 021-29478974 , 081289462227 , email : sales@kyoritsuindonesia.com

KYORITSU News

Clamp Sensors

Flexible Clamp Sensor KEW 8130 • Ø110mm • Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at...

Others

Illuminometer MODEL 5201 • Digital Illuminometer • Model 5201 is a highly portable and compact digital illuminometer for measuring illuminance from 0.1 to 19,990 Lux, with auto...

KT 171

Jual Kyoritsu Voltage Testers KT 171   Voltage Testers KT 171   • AC and DC voltage tests up to 690V with LEDs and LCD • Comply with the...

KT 170

Jual Kyoritsu Voltage Testers KT 170   Voltage Testers KT 170     • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

Voltage Testers

Kyoritsu Indonesia - Jual Kyoritsu Voltage Testers Voltage Testers KT 170 • AC and DC voltage tests up to 690V with LED • Comply with the latest standards...

KEW 8031F

Jual Kyoritsu Phase Indicators KEW 8031F   Phase Indicators KEW 8031F   • KEW8031F is designed to check phase sequence. Lamps provided on the unit will also tell you if...

MODEL 8031

Jual Kyoritsu Phase Indicators MODEL 8031   Phase Indicators MODEL 8031   • Digital Phase Indicator with open phase checker. • Phase indicator designed to check the presence of open...

MODEL 8030

Jual Kyoritsu Phase Indicators MODEL 8030   Phase Indicators MODEL 8030   • Digital Phase Indicator with open phase checker • Phase indicator designed to check the presence of open...

KEW 8035

Jual Kyoritsu Non-Contact Safety Phase Indicator KEW 8035   Non-Contact Safety Phase Indicator KEW 8035   • New technology permits safe testing, without the need of direct contact between probes...

Phase Indicator

Kyoritsu Indonesia - Jual Kyoritsu Phase Indicator Non-Contact Safety Phase Indicator KEW 8035 Safe Testing without direct contact with live wires!! • New technology permits safe testing, without...

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A   Portable Appliance Testers KEW 6201A   The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of...

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140   LOOP/PFC/PSC Testers KEW 4140   • Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. •...

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A   LOOP/PFC/PSC Testers MODEL 4118A     • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status....

KEW 5410

Jual RCD Testers KEW 5410   RCD Testers KEW 5410   • Measurement of RCD trip time  Conducting testing of rated residual non-operating currents at  × 1/2 Range, measuring RCD...

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A   RCD Testers MODEL 5406A   • Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. •...

KYORITSU Video

Guests Online

We have 23 guests and no members online

Quality Control Concept

Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter. Learn More...