JUAL PRODUK ROHDE & SCHWARZ

Jual Rohde and Schwarz dengan harga murah dan bergaransi

JUAL PRODUK FLIR INDONESIA HARGA MURAH

Jual Produk Flir dengan harga murah

Jual Anritsu Indonesia

Jual Anritsu dengan harga murah dan bergaransi resmi

Jual Keithley, Keithley Indonesia, Distributor Keithley, Harga Keithley, Keithley Murah

Jual Tekiro - Tekiro Indonesia

Distributor Tekiro Indonesia, Harga Tekiro, Tekiro Murah

Kikusui Indonesia - Ametek Indonesia

Kikusui Indonesia - Ametek Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Jual Alat Safety Indonesia

Jual Alat Safety Indonesia, Yotsugi Indonesia, Respirex Indonesia, Regeltex Indonesia, Bushnell Indonesia

Jual Ritz Telescopic Hot Stick - Sensorlink

Jual Ritz Telescopic Hot Stick ,Jual Sensorlink Indonesia dengan harga murah
Home  //  Others  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

MODEL 2010

AC/DC Digital Clamp Meters

MODEL 2010

 

MODEL 2010
 
• High sensitivity, miniature AC/DC clamp meter.
• 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
• Output terminal for recorder connection.

φ7.5 DCACA MAX20A OutPut External

Never make current measurement on a circuit above 60V AC/DC
as the instrument is designed for use on low voltage circuits only.

 

AC A 200mA/2/20A
±1%rdg±2dgt [50/60Hz] (200mA)
±1.5%rdg±4dgt [40Hz - 2kHz] (200mA)
±1%rdg±2dgt [50/60Hz] (2A)
±2.5%rdg±5dgt [40Hz - 2kHz] (2/20A)
DC A 2/20A
±1%rdg±2dgt (2A)
±1.5%rdg±4dgt (20A)
Conductor size Ø7.5mm max.
Frequency response DC, 40Hz - 2kHz
Output Recorder :
DC200mV against AC200mA/2/20A
DC200mV against DC2/20A
Power source 6LF22(9V) × 1 or AC Adaptor
Dimensions 142(L) × 64(W) × 26(D)mm
153(L) × 23(W) × 18(D)mm
Clamp Sensor
Weight 220g approx.
Included Accessories 9071 (Carrying Case)
Alkaline 6LF22 × 1
Instruction Manual
Optional Accessories 8022 (AC Adaptor) (110V)
8023 (AC Adaptor) (220V)
7256 (Output cord)

 

KEW 2009R

AC/DC Digital Clamp Meters

KEW 2009R

 

KEW 2009R
CE
 
• CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
• Accurate True-RMS reading of AC current or voltage with distorted waveform.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.

TRUE RMS CAT4 600V φ55 MAX2000A DCACA DCACV Resistance Continuitybuzzer FrequencyDATAHOLD PeakHold10ms OutPut AutoPowerOff

 

 

AC A 400.0/2000A
±1.3%rdg±3dgt (0 - 400.0A, 150 - 1700A) (45 - 66Hz)
±2.0%rdg±5dgt (0 - 400.0A, 150 - 1700A) (20Hz - 1kHz)
±2.3%rdg±3dgt (1701 - 2000A) (45 - 66Hz)
DC A 400.0/2000A±1.3%rdg±2dgt
AC V 40.00/400.0/750V
±1.0%rdg±3dgt (45 - 66Hz)
±1.5%rdg±5dgt (20Hz - 1kHz)
DC V 40.00/400.0/1000V±1.0%rdg±2dgt
Ω 400.0/4000Ω ±1.5%rdg±2dgt
(Electronic protection (no fuse) up to 600V)
Continuity buzzer Buzzer sounds below 20Ω
Hz 10.0 - 4000Hz±1.5%rdg±5dgt
(Input sensitivityCurrent: more than 40AVoltage: more than 10V)
Conductor size Ø55mm max.
Output Recorder :
DC400mV against AC/DC400.0A
DC200mV against AC/DC2000A
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1
Power source R6 (1.5V) × 2
Dimensions 250(L) × 105(W) × 49(D)mm
Weight Approx. 540g (including batteries)
Included Accessories 7107A (Test leads), 8201 (Output plug), 9094 (Carrying case)
R6 (AA) (1.5V) × 2, Instruction Manual
Optional Accessories 8008 (Multi-Tran) (AC only), 7256 (Output cord)

 

KEW 2003A

AC/DC Digital Clamp Meters

KEW 2003A

 

KEW 2003A
CE
 
• Equipped to measure both AC and DC current with transformer jaws of large diameter.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.

CAT4 600V φ55 MAX2000A DCACA DCACV Resistance Continuitybuzzer DATAHOLD OutPut AutoPowerSave

 

 

 

AC A 400A/2000A (0 - 1000A)
±1.5%rdg±2dgt [50/60Hz]
±3%rdg±4dgt [40 - 500Hz]
±5%rdg±4dgt [500Hz - 1kHz]
2000A (1001 - 2000A)
±3%rdg±2dgt [50/60Hz]
DC A 400/2000A ±1.5%rdg±2dgt
AC V 400/750V
±1.5%rdg±2dgt [50/60Hz]
±1.5%rdg±4dgt [40Hz - 1kHz]
DC V 400/1000V ±1%rdg±2dgt
Ω 400/4000Ω ±1.5%rdg±2dgt
Continuity buzzer buzzer sounds below 50±35Ω
Conductor size Ø55mm max.
Frequency response 40Hz - 1kHz
Output Recorder :
DC400mV against AC/DC400A
DC200mV against AC/DC2000A
Safety Standard IEC 61010-1 CAT IV 600V , CAT III 1000V
IEC 61010-031
IEC 61010-2-032
Power source R6 (AA) (1.5V) × 2
Dimensions 250(L) × 105(W) × 49(D)mm
Weight 530g approx.
Included Accessories 7107A (Test leads)
8201 (Output Plug)
9094 (Carrying Case)
R6 (AA) × 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran) (AC only)
7256 (Output cord)

 

Guests Online

We have 19 guests and no members online