JUAL PRODUK ROHDE & SCHWARZ

Jual Rohde and Schwarz dengan harga murah dan bergaransi

JUAL PRODUK FLIR INDONESIA HARGA MURAH

Jual Produk Flir dengan harga murah

Jual Anritsu Indonesia

Jual Anritsu dengan harga murah dan bergaransi resmi

Jual Keithley, Keithley Indonesia, Distributor Keithley, Harga Keithley, Keithley Murah

Jual Tekiro - Tekiro Indonesia

Distributor Tekiro Indonesia, Harga Tekiro, Tekiro Murah

Kikusui Indonesia - Ametek Indonesia

Kikusui Indonesia - Ametek Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Jual Alat Safety Indonesia

Jual Alat Safety Indonesia, Yotsugi Indonesia, Respirex Indonesia, Regeltex Indonesia, Bushnell Indonesia

Jual Ritz Telescopic Hot Stick - Sensorlink

Jual Ritz Telescopic Hot Stick ,Jual Sensorlink Indonesia dengan harga murah
Home  //  Others  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2500

DC Milliamp Clamp Meter

KEW 2500

 

KEW 2500
CE
 
• 0.01mA resolution for DC current
• Top class measurement 0.2% accuracy
• Ø6mm clamp jaw easy to use in tight places
• Measurement from 0.01mA to 120.0mA
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span
• Spotlight for illuminating measurement point
• Analog output terminal for recorder connection
• Complies with IEC 61010-1 CAT II 300V

φ6 DCA Backlight DATAHOLD AutoPowerOff OutPut

 

 

DC A 20/100mA (Auto ranging)
±0.2%rdg±5dgt (0.00mA - 21.49mA)
±1.0%rdg±5dgt (21.0mA - 120.0mA)
Conductor size Ø6mm max.
Analog output Recorder: DC 1000mV against DC 100mA
Applicable standards IEC 61010-1, 61010-2-030 CAT II 300V
IEC 61010-2-032
IEC 61326-1, 61326-2-2
IEC 60529 IP40
Operating temperature & humidity range -10 - +50ºC < 85%
Storage temperature & humidity range -20 - +60ºC < 85%
Power source R6/LR6 (AA) (1.5V) × 4
Dimensions 111(L) × 61(W) × 40(D)mm : Display unit
104(L) × 34(W) × 20(D)mm : Sensor
700mm : Sensor cable
Weight Approx. 290g (including batteries)
Included Accessories 9096 (Carrying case), LR6 (AA) × 4,
Instruction Manual
Optional Accessories 7256 (Output cord)

 

Multimeters

Digital Multimeter with AC/DC Clamp Sensor

  • KEWMATE 2000

    KEWMATE 2000

    • Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR.
    • 3400 counts with bargraph display.
    • Pocket size and heavy duty design.

    φ6 MAX60A DCACV DCACA Resistance Continuitybuzzer Frequency DATAHOLD AutoPowerSave
    • KEWMATE 2001  

      KEWMATE 2001

      • Capable of measuring AC and DC currents up to 100A with OPEN CLAMP SENSOR.
      • 3400 counts with bargraph display.
      • Pocket size and heavy duty design.

      φ10 MAX100A DCACV DCACA Resistance Continuitybuzzer Frequency DATAHOLD AutoPowerSave
      •    KEWMATE 2012R

        KEWMATE 2012R

        • Innovative Multimeters with current measurements up to 120A AC/DC
        • Unique Open Jaw technology for AC/DC current measurements
        • Very compact and as reliable as a tradictional full size multimeter

        TRUE RMS φ12 MAX120A DCACV DCACA Resistance Continuitybuzzer Diode CapacitanceFrequency DATAHOLD AutoPowerSave  

Digital Multimeters

  • KEW 1019R

    KEW 1019RNEW

    • Elegant shiny-black finish
    • Comes with user-friendly Hard case
    • Large Display
    • Accurate reading with True-RMS technology
    • Electronic protection (no fuse!) on ohm and continuity ranges
    • Safety Standard IEC 61010-1 / 61010-031 / 61010-2-033 CAT III 300V / CAT II 600V

    TRUE RMS DCACV Resistance Continuitybuzzer Capacitance Relative AutoPowerSave
    •    KEW 1020R

      KEW 1020RNEW

      • Large display with 6000 counts and Backlight
      • True-RMS
      • MIN/MAX function
      • Rugged and reliable
      • Clamp sensor mode
      • IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V

      TRUE RMS CAT4 300V CAT3 600V DCACV Resistance Continuitybuzzer Diode Capacitance Frequency DUTYBacklight DATAHOLD Relative MAX/MIN AutoPowerSave  
      • KEW 1021R

        KEW 1021RNEW

        • Elegant and easy-to-use cabinet
        • Large display with 6000 counts and Backlight
        • Enhanced current measuring function using an external clamp sensor
        • Two detachable holders, flat and wing type
        • Accurate reading with True RMS
        • Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V

        TRUE RMS CAT4 300V CAT3 600V DCACV DCACA Resistance Continuitybuzzer Diode CapacitanceFrequency DUTY Backlight DATAHOLD Relative MAX/MIN AutoPowerSave
        • MODEL 1009

          MODEL 1009

          • Display : 4000 counts.
          • Auto range and manual range selector provided.
          (with range hold feature)
          • Resistance range provides audible continuity test.
          • Automatically turns power off in about 30 minutes to conserve battery life.
          • Direct current measurement up to 10A AC and DC.
          • With Holster.

          DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DUTY DATAHOLD Relative AutoPowerOff
          • KEW 1011

            KEW 1011

            • Temperature measurement, selectable for ºC and ºF
            • 6040 counts with Bar Graph display
            • MIN/MAX function enables to record min & max value
            • REL(relative value) function to indicate the measurement variation

            DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Temperature DATAHOLD MAX/MIN Relative AutoPowerOff
            • KEW 1012

              KEW 1012

              • True RMS can measure and indicate distorted waveforms
              • 6040 counts with Bar Graph display
              • MIN/MAX function enables to record min & max value
              • REL(relative value) function to indicate the measurement variation

              TRUE RMS DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Temperature DATAHOLD MAX/MIN Relative AutoPowerOff
              • KEW 1018/1018H

                KEW 1018/1018H

                • Display : 4000 counts.
                • Auto range.
                • Diode test feature.
                • Capacitance test feature.
                • Continuity test.

                • DCACV Resistance Continuitybuzzer Diode Capacitance Frequency DUTY DATAHOLD Relative AutoPowerOff
                • KEW 1030

                  KEW 1030

                  • Compact in Size, Light in Weight and Simple in Use.
                  • Double moulding provides comfortable and good feeling in hand.
                  • Penlight illuminates brightly the point to be measured, even in dark place.
                  • Backlight LCD is highly visible, even in darkness.
                  • Unique wrapping mechanism for test lead in the rear side compartment.
                  • Unique protection mechanism for the test prod for safety.
                  • All ranges including Ohm range are protected against overload voltage of 600V.

                  • DCACV Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Backlight DATAHOLD Relative AutoPowerOff
                  • KEW 1051

                    KEW 1051

                    For Electrical and Electronic Troubleshootings
                    • High Accuracy, High Performance and Reliable Measurements
                    • Safety design for industrial use

                    • TRUE RMS CAT4 600V DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency Temperature Backlight DATAHOLD Relative Filter AutoPowerOff
                    • KEW 1052

                      KEW 1052

                      For Electrical and Electronic Troubleshootings
                      • High Accuracy, High Performance and Reliable Measurements
                      • Safety design for industrial use
                      • Reliable support for data management

                      • TRUE RMS CAT4 600V DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency Temperature Backlight DATAHOLD MAX/MIN/AVG Relative FilterUSBAutoPowerOff
                      • KEW 1061

                        KEW 1061

                        For Electrical and Electronic Troubleshootings
                        • High Accuracy, High Performance and Reliable Measurements
                        • Safety design for industrial use
                        • Reliable support for data management

                        • TRUE RMS CAT4 600V DCACV DCACA DC+AC Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Temperature Decibel
                        • Backlight DATAHOLD MAX/MIN/AVG Relative Filter USB AutoPowerOff
                        • KEW 1062

                          KEW 1062

                          For Electrical and Electronic Troubleshootings
                          • High Accuracy, High Performance and Reliable Measurements
                          • Safety design for industrial use
                          • Reliable support for data management

                          • TRUE RMS CAT4 600V DCACV DCACA DC+AC Resistance LowPowerΩ Continuitybuzzer Diode Capacitance Frequency DUTY Temperature
                          • Decibel Backlight DATAHOLD Peakhold MAX/MIN/AVG Relative Filter USB AutoPowerOff

Analogue Multimeters

  • KEW 1109S

    KEW 1109S

    • Mirrored scale for easy and accurate reading.
    • Output terminal to cut off DC component when measuring AC voltage.
    • Safety designed input terminals and test leads.

    • DCACV DCA Resistance Decibel
    • MODEL 1110

      MODEL 1110

      •High sensitivity DC20kΩ/V.
      •1m drop-proof heavy duty designed taut-band movement.
      •Can measure line voltage up to AC 600V.
       (Voltage to ground MAX AC300V)
       (Protected by 600V ceramic fuse against accidental overload)
      •Continuity buzzer, battery check, LED check, temperature
       measurement function.
      •Skeleton type robust and clear case
       with carrying handle furnished as standard accessory.

      • DCACV DCA Resistance Continuitybuzzer Temperature

MODEL 1110

Analogue Multimeters

MODEL 1110

 

MODEL 1110
CE
 
• High sensitivity DC20kΩ/V.
• 1m drop-proof heavy duty designed taut-band movement.
• Can measure line voltage up to AC 600V.
 (Voltage to ground MAX AC300V)
 (Protected by 600V ceramic fuse against accidental overload)
• Continuity buzzer, battery check, LED check, temperature
 measurement function.
• Skeleton type robust and clear case
 with carrying handle furnished as standard accessory.

DCACV DCA Resistance Continuitybuzzer Temperature

 

 

DC V 0.3V (16.7kΩ/V) ±3% of FS
3/12/30/120/300/600V (20kΩ/V)
±3% of FS
AC V 12V (9kΩ/V) ±4% of FS
30/120/300/600V (9kΩ/V)
±3% of FS
DC A 60µA/30/300mA
±3% of FS
Ω 3/30/300kΩ
±3% of scale length
Continuity buzzer Buzzer sounds below 100Ω
Battery Test 1.5V (0.7 - 2V)
±3% of FS (10Ω load)
Temperature -20ºC - +150ºC
±3% of scale length (0ºC - +100ºC)
±4% of scale length (other ranges)
(with the use of Temperature probe 7060)
LED 10mA approx. at 0 Ω
(at 3V of battery voltage)
Applicable standards IEC 61010-1
 CAT III 300V Pollution Degree 2
 CAT II 600V Pollution Degree 2
IEC 61010-2-031
Power source R6 (AA) (1.5V) × 2
Dimensions 140(L) × 94(W) × 39(D) mm
Weight 280g approx.
Included Accessories 7066A (Test leads)
8923 (F500mA/600V fuse) × 2
R6 (AA) × 2
9103 (Carrying case)
Instruction Manual
Optional Accessories 7060 (Temperature probe)

 