JUAL PRODUK ROHDE & SCHWARZ

Jual Rohde and Schwarz dengan harga murah dan bergaransi

JUAL PRODUK FLIR INDONESIA HARGA MURAH

Jual Produk Flir dengan harga murah

Jual Anritsu Indonesia

Jual Anritsu dengan harga murah dan bergaransi resmi

Jual Keithley, Keithley Indonesia, Distributor Keithley, Harga Keithley, Keithley Murah

Jual Tekiro - Tekiro Indonesia

Distributor Tekiro Indonesia, Harga Tekiro, Tekiro Murah

Kikusui Indonesia - Ametek Indonesia

Kikusui Indonesia - Ametek Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Jual Alat Safety Indonesia

Jual Alat Safety Indonesia, Yotsugi Indonesia, Respirex Indonesia, Regeltex Indonesia, Bushnell Indonesia

Jual Ritz Telescopic Hot Stick - Sensorlink

Jual Ritz Telescopic Hot Stick ,Jual Sensorlink Indonesia dengan harga murah
Home  //  Others  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 1052

Digital Multimeters

KEW 1052

 

KEW 1052
CE
 
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• True-RMS or MEAN value detection mode can be selected
• Low-pass filter for motor drive measurements
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC

Reliable support for data management
• Large data internal memory 1,600 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
*MAX 32,767 data can be transferred.

TRUE RMS CAT4 600V DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency Temperature Backlight DATAHOLD MAX/MIN/AVG Relative Filter USB AutoPowerOff

 

 
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency 10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature -50 - 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)

 

Option

 

DescriptionModelSpecification
Crocodile clip test lead 7234 CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor 8115 AC 130A / DC 180A
Clamp sensor 8121 AC 100A
8122 AC 500A
8123 AC 1000A
8146 AC 30A
8147 AC 70A
8148 AC 100A
Banana Ø4mm Adjuster Plug 7146 length:190mm
USB Communication set 8241 USB adaptor + USB cable + DMM Software
DMM Printer full set 8249 8243+8246+8248
  Printer Communication set 8243 Printer Adapter + RS232 cable
Printer 8246 Printer + Thermal paper (1 roll)
AC adapter for printer [EU] 8248A AC230V±10%
Thermal paper for printer 8247 10 rolls
Carrying case 9154 for the main unit with testi leads and communication cable

 

Thermocouple Type K Specification

 

DescriptionModelSpecification
Temperature probes 8405 Max. 500ºC
(Surface type, Point material: Ceramic)
8406 Max. 500ºC (Surface type)
8407 Max. 700ºC (Liquid, Semi-solid)
8408 Max. 600ºC (Air, Gas)

 

KEW 1051

Digital Multimeters

KEW 1051

 

KEW 1051
CE
 
High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• Low-pass filter for motor drive measurements
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC

TRUE RMS CAT4 600V DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency Temperature Backlight DATAHOLD Relative Filter AutoPowerOff

 

 
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency 10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature -50 - 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Zero Adjustment (Capacitor, Resistance), LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Display 6,000 counts
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)

 

Option

 

DescriptionModelSpecification
Crocodile clip test lead 7234 CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor 8115 AC 130A / DC 180A
Clamp sensor 8121 AC 100A
8122 AC 500A
8123 AC 1000A
8146 AC 30A
8147 AC 70A
8148 AC 100A
Banana Ø4mm Adjuster Plug 7146 length:190mm
Carrying case 9154 for the main unit with testi leads and communication cable

 

Thermocouple Type K Specification

 

DescriptionModelSpecification
Temperature probes 8405 Max. 500ºC
(Surface type, Point material: Ceramic)
8406 Max. 500ºC (Surface type)
8407 Max. 700ºC (Liquid, Semi-solid)
8408 Max. 600ºC (Air, Gas)

 

KEW 1030

Kyoritsu Indonesia - Jual Digital Multimeters KEW 1030

KEW 1030

 

KEW 1030
CE
 
• Compact in Size, Light in Weight and Simple in Use.
• Double moulding provides comfortable and good feeling in hand.
• Penlight illuminates brightly the point to be measured, even in dark place.
• Backlight LCD is highly visible, even in darkness.
• Unique wrapping mechanism for test lead in the rear side compartment.
• Unique protection mechanism for the test prod for safety.
• All ranges including Ohm range are protected against overload voltage of 600V.

DCACV Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Backlight DATAHOLD Relative AutoPowerOff

 

■Long life LED light is of good use in dark place ■Protection cover prevents unforeseen accident
■Wrapping mechanism for test lead in rear side compartment

* Length of test lead is adjustable in 3 steps, ie, 60cm, 40cm and 20cm.

 

DC V 400m/4/40/400/600V (5 Range auto)
±0.8%rdg ±5dgt(400mV - 400V)
±1.0%rdg ±5dgt(600V)
AC V 4/40/400/600V (4 Range auto)
±1.3%rdg ±5dgt (4/40V) (50/60Hz)
±1.6%rdg ±5dgt (400/600V) (50/60Hz)
Ω 400/4k/40k/400k/4M/40MΩ (6 Range auto)
±1.0%rdg ±5dgt (400Ω - 4MΩ)
±2.5%rdg ±5dgt (40MΩ)
Continuity buzzer Buzzer sounds when resistance is 120Ω or less.
Diode test Test voltage approx. 0.3 - 1.5V
Capacitance 50n/500n/5µ/50µ/100µF (5 Range auto)
±3.5%rdg ±10dgt (50nF)
±3.5%rdg ±5dgt (500n - 50µF)
±4.5%rdg ±5dgt (100µF)
Frequency 5/50/500/5k/50k/200kHz
±0.1%rdg ±5dgt (Measurable input: 1.5Vrms or more)
DUTY 0.1 - 99.9%
±2.5%rdg ±5dgt (Pulse width / Pulse cycle)
Measurement functions The measured value can be hold by pressing Data hold button
Other functions When the battery voltage drops to 2.4V±0.2V or less
Built-in
Applicable standards IEC 61010-1: 2001 CAT III 600V
IEC 61010-031
IEC 61326-1
Power source Button type battery LR44 (SR44)1.5V × 2
Dimensions 190(L) × 39(W) × 31(D)mm
Weight Approx. 100g (including batteries
Included Accessories Carrying case, LR44 (1.5V) × 2, Instruction manual

 

Guests Online

We have 29 guests and no members online