JUAL PRODUK ROHDE & SCHWARZ

Jual Rohde and Schwarz dengan harga murah dan bergaransi

JUAL PRODUK FLIR INDONESIA HARGA MURAH

Jual Produk Flir dengan harga murah

Jual Anritsu Indonesia

Jual Anritsu dengan harga murah dan bergaransi resmi

Jual Keithley, Keithley Indonesia, Distributor Keithley, Harga Keithley, Keithley Murah

Jual Tekiro - Tekiro Indonesia

Distributor Tekiro Indonesia, Harga Tekiro, Tekiro Murah

Kikusui Indonesia - Ametek Indonesia

Kikusui Indonesia - Ametek Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Jual Alat Safety Indonesia

Jual Alat Safety Indonesia, Yotsugi Indonesia, Respirex Indonesia, Regeltex Indonesia, Bushnell Indonesia

Jual Ritz Telescopic Hot Stick - Sensorlink

Jual Ritz Telescopic Hot Stick ,Jual Sensorlink Indonesia dengan harga murah
Home  //  Others  //  ABB  //  Control Products  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 4300

Jual Earth Testers KEW 4300

 

Earth Testers

KEW 4300

KEW 4300
CE
New Simplified Earth Tester
KEW 4300 is simplified earth resistance tester (based on 2-pole method) that can be used for various distribution lines and electrical appliances and it also can measure AC/DC voltage. (As for AC Voltages, true rms values can be obtained.)

• 200/2000Ω (2 ranges): auto-ranging.
• Warning buzzer triggered at 100Ω or less.
• LED lights up when a large earth voltage is detected.
• Live circuit warning when 30V or higher voltage is detected. (KEW 4300 detects voltage even when measuring resistances.)
• LED light for illuminating measurement points.
(It turns on/off automatically in relation to the ambient brightness.)
• Small test current (max 2mA) not triggering RCD.
  • TRUE RMS Backlight AutoPowerOff
 
Earth resistance ranges 200.0/2000Ω (Auto ranging)
±3%rdg±5dgt
Voltage ranges AC: 5.0 - 300.0V (45 - 65Hz)±1%rdg±4dgt
DC: ±5.0 - 300.0V±1%rdg±8dgt
Applicable standards IEC 61010-1 CAT III 300V pollution degree 2
IEC 61010-031, 61557-1, -5
IEC 61326-1, 2-2, IEC 60529 (IP40)
Power source Size AA alkaline battery × 2pcs
Dimensions 232(L) × 51(W) × 42(D)mm
Weight 220g approx. (including battery)
Included Accessories 7248 (Test lead with Alligator clip and Flat test probe)
8072 (CAT II Standard prod)
8253 (CAT III Standard prod)
8017 (Extension prod long)
9161 (Carrying case)
Instruction manual, LR6 (AA) × 2

 

MODEL 4105A

Jual Earth Testers MODEL 4105A

 

Earth Testers

MODEL 4105A

MODEL 4105A
CE
 
• Dust and drip proof.(designed to IEC 529 IP54)
• In addition to the facility for precision measurement, test leads for simplified two wire easuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
4105A Soft Case Model4105A-H Hard Case Model
Measurement ranges Earth Resistance: 0 - 20Ω/0 - 200Ω/0 - 2000Ω
Earth Voltage [50,60Hz]: 0 - 200V AC
Accuracy Earth Resistance: ±2%rdg±0.1Ω (20Ωrange)
±2%rdg±3dgt (200Ω/2000Ωrange)
Earth Voltage: ±1%rdg±4dgt
Overload protection Earth Resistance: 280V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage: 300V AC for 1 minute
Applicable standards IEC 60529 IP54
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557
Power source R6 (AA) (1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D)mm
Weight 550g approx.
Included Accessories 7095A (Earth resistance test leads) × 1set
(red-20m, yellow-10m, green-5m)
8032 (Auxiliary earth spikes) × 1set
7127A (Simplified measurement probe) × 1set
R6 (AA) × 6
9121 (Shoulder strap)
Instruction Manual
Carrying case : 9084(Carrying case[Soft]:4105A only)
       : 9165(Carrying case[Hard]:4105A-H only)
Optional Accessories 7100A (Precision measurement cord set)

 

Earth Testers

Jual Earth Testers Kyoritsu Harga Murah

Earth Testers

  • MODEL 4102A

    MODEL 4102A

    • The latest circuit design permits the instrument to operate
     with the minimum of influence from earth voltage
     and earth resistance of auxiliary earth spikes.
    • Dust and drip proof. (designed to IEC 529 IP54)
    • Earth resistance value can be read directly from the scale.
    • Designed to meet IEC 61010-1 safety standard.
    • Capable of measuring earth voltage.
    • Small and lightweight. Shock resistant new case material.
    • 2mA measuring current permits earth resistance tests
     without tripping earth leakage current breakers
     in the circuit under test.
    • Lead wire connection to C and P terminals and proper
     auxiliary earth resistance can be checked by "OK" lamp.
     Lead wire connection to C and E terminals is good
     when "OK" lamp is illuminated.

    • MODEL 4105A

      MODEL 4105A

      • Dust and drip proof.(designed to IEC 529 IP54)
      • In addition to the facility for precision measurement, test leads for simplified two wire easuring system also supplied as standard accessories.
      (unit can be hung from the neck for simplified measurement)
      • Designed to meet IEC 61010-1 safety standard.
      • Capable of measuring earth voltage.
      • Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
      • Small and lightweight. Shock resistant new case material.
      • 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

      • KEW 4300

        KEW 4300

        KEW 4300 is simplified earth resistance tester
        (based on 2-pole method)

        • 200/2000Ω (2 ranges): auto-ranging.
        • Warning buzzer triggered at 100Ω or less.
        • LED lights up when a large earth voltage is detected.
        • Live circuit warning when 30V or higher voltage is detected.
        (KEW 4300 detects voltage even when measuring resistances.)
        • LED light for illuminating measurement points.
        (It turns on/off automatically in relation to the ambient brightness.)
        • Small test current (max 2mA) not triggering RCD.

        • TRUE RMS Backlight AutoPowerOff

Earth Resistance & Resistivity Tester

  • KEW 4106

    KEW 4106

    Earth Resistance Measurements with 4, 3 and 2 Wires
    Earth Resistivity (ρ) Measurement using WENNER method

    • Backlight

Earth Clamp Testers

  • MODEL 4200

    MODEL 4200

    • The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes. (The Multiple Earthing System.)
    • True RMS
    Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
    • Noise Check Function
    A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.
    • Memory function
    Save and display up to 100 measurement data.
    • Data hold function / Buzzer function / Back light function
    • Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2

    • TRUE RMS φ32 Backlight
    • KEW 4202

      KEW 4202

      Various useful functions are available on Android devices using Bluetooth communication
      • Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)
      • Saved data includes measurement, GPS location and date & time
      Easy to check on map "When" and "Where" the measurement was made
      • Comparator function on Android device informs when the measured value is lower/higher than the preset value

      Earth /Ground resistance and Leakage current measurement functions
      • The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems
      • True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks
      • Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments

      • TRUE RMS φ32 Backlight Bluetooth

MODEL 4102A

Jual Earth Testers MODEL 4102A

 

Earth Testers

MODEL 4102A

MODEL 4102A
CE
4102A Soft Case Model
4102A-H Hard Case Model
• The latest circuit design permits the instrument to operate
 with the minimum of influence from earth voltage
 and earth resistance of auxiliary earth spikes.
• Dust and drip proof. (designed to IEC 529 IP54)
• Earth resistance value can be read directly from the scale.
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests
 without tripping earth leakage current breakers
 in the circuit under test.
• Lead wire connection to C and P terminals and proper
 auxiliary earth resistance can be checked by "OK" lamp.
 Lead wire connection to C and E terminals is good
 when "OK" lamp is illuminated.
4102A Soft Case Model4102A-H Hard Case Model
Measurement ranges Earth Resistance: 0 - 12 Ω/0 - 120 Ω/0 - 1200 Ω
Earth Voltage [50,60Hz]: 0 - 30V AC
Accuracy Earth Resistance: ±3% of full scale
Earth Voltage: ±3% of full scale
Overload protection Earth Resistance: 276V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage: 276V AC for 1 minute
Applicable standards IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557
IEC 60529 IP54
Power source R6 (AA) (1.5V) × 6
Dimensions 105(L) × 158(W) × 70(D)mm
Weight 600g approx.
Included Accessories 7095A (Earth resistance test leads) × 1set
(red-20m, yellow-10m, green-5m)
8032 (Auxiliary earth spikes) × 1set
7127A (Simplified measurement probe) × 1set
R6 (AA) × 6
9121 (Shoulder strap)
Instruction Manual
Carrying case : 9084(Carrying case[Soft]:4102A only)
       : 9164(Carrying case[Hard]:4102A-H only)
Optional Accessories 7100A (Precision measurement cord set)

 

KEW 3128

Jual High Voltage Insulation Testers KEW 3128

 

High Voltage Insulation Testers

KEW 3128

KEW 3128
CE AutoDischarge
 
• Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.
• Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.
• 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V
Fine adjustment of voltage setting at each range is also possible
• Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.
• Can be operated from built-in rechargeable battery or from AC line.
• Automatic discharge after test with monitoring of the discharge voltage.
• Internal memory can store about 43,000 data (max).
• Robust design for field use with IP64 rating (with lid closed).
  • CAT4 600V DCACV Backlight USB AutoPowerOff 500V 1000V 2500V 5000V 1KV~10KV 12KV External
 

Insulation resistance (*): Accuracy is not guaranteed with setting of 250V or less

Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
Max measurement value 500GΩ 1TΩ 2.5TΩ 5TΩ 35TΩ
Accuracy 400k~50GΩ ±5%rdg±3dgt
(*)
800k~100GΩ 5%rdg±3dgt 2M~250GΩ ±5%rdg±3dgt 4M~500GΩ ±5%rdg±3dgt 8M~1TΩ ±5%rdg±3dgt
50G~500GΩ
±20%rdg
(*)
100G~1TΩ
±20%rdg
250G~2.5TΩ
±20%rdg
500G~5TΩ
±20%rdg
1T~10TΩ
±20%rdg
10T - 35TΩ
Values are displayed, but accuracy isn't guaranteed
Short circuit current Max 5.0mA
Load resistor to output rated voltage 0.5MΩ or more 1MΩ or more 2.5MΩ or more 5MΩ or more 20MΩ or more 24MΩ or more

Output voltage

Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
Monitor accuracy ±10%±20V ±10%±20V ±10%±20V ±10%±20V ±10%±20V ±10%±20V
Output accuracy 0 - +20% 0 - +10% 0 - +10% 0 - +10% -5 - +5% -5 - +5%
Selectable range 50 - 600V
(in steps of 5V)
610 - 1200V (in steps of 10V) 1225 - 3000V (in steps of 25V) 3050 - 6000V (in steps of 50V) 6100 -
10000V (in steps of 100V)
10100 - 12000V (in steps of 100V)

Voltage measurement

Measuring range DCV:±30 ~ ±600V、ACV:30 ~ 600V (50/60Hz)
Accuracy ±2%rdg±3dgt

Current measurement

Measuring range 5.00nA - 2.40mA (Depending on the insulation resistance)

Capacitance measurement

Measuring range 5.0nF ~ 50.0μF
(500V/1000V/2500V/5000V)
5.0nF - 1.0µF (display range: 5.0nF - 50.0µF) (10000V/12000V)
Accuracy ±5%rdg±5dgt

General

Applicable standards IEC 61010-1 CAT IV 600V Pollution degree 2,
IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.
Operating temperature & humidity range -10ºC - Relative humidity 85% or less
50ºC /(when operating with an external power supply, no condensation)
0ºC - 40ºC /Relative humidity 85% or less
(when operating with battery, no condensation)
Storage temperature & humidity range -20ºC - 60ºC / Relative humidity 75% or less (no condensation)
Power source Rechargeable Lead storage battery (12V)*
Charging time: approx. 8 hours / AC Power supply (100V - 240V, 50/60Hz)
* Continuous measuring time:
approx. 4 hours
(a load of 100MΩ at the Insulation resistance 12000V Range.)
approx. 2 hours
(Max current consumption in range while rated currents are maintained.)
Dimensions 330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case
Weight 9kg approx. (including battery) *Instrument and Hard case
Included Accessories 7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe),
7227A (Line probe with alligator clip), 8029 (Extension prod),
8212-USB-W (USB adaptor with KEW Windows (Software)),
Instruction manual
Optional Accessories 7254 (Longer Line probe with alligator clip)

 

206741
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
36
84
710
205067
2351
5007
206741

Your IP: 18.210.22.132
Server Time: 2019-10-19 08:15:41