Home  //  Products  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 6016

Jual Multi Function Testers KEW 6016

 

Multi Function Testers

KEW 6016

KEW 6016
CE AutoDischarge ATT
 
Continuity Measurement
Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display.

Insulation Measurement
Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display.

Loop Impedance Measurement
A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's.
A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW 6016 allows also for phase to phase loop tests.

PSC / PFC Measurement
The Prospective Short Circuit Current (PSC) and Prospective Fault Current (PFC) are automatically calculated and shown on the display. As loop testing, the function has low and high test current options with the default to low current to avoid inadvertent tripping of RCDs.

RCD Measurement
The KEW 6016 has a comprehensive RCD test feature for RCD type AC (Alternative Currents), RCD type A (Pulsating Direct Currents), General and Selective (delayed).

Measures at 1/2x, 1x, 5x of nominal RCD current. It also has Ramp Test and Auto test where all results are shown on one screen. Touch voltage limit can be selected for 25V or 50V depending on application.

Earth Measurement
Using the classical Volt-Amper method with two auxiliary earth spikes and without external power source. All test leads and spikes are supplied as standard accessories.

Phase rotation
KEW 6016 can check the phase rotation of three phase lines with clear indication of the sequence on the display.

Voltage Measurement
In addiction to the voltage measurement, this function gives also the Frequency of the voltage under test.

Continuity
Range 20/200/2000Ω (Auto-ranging)
 Open circuit
voltage (DC)
5V±20% (*1)
Short circuit
current
Greater than 200mA
Accuracy  ±0.1Ω (0 - 0.19Ω)
±2%rdg+8dgt (0.2 - 2000Ω) 
Insulation Resistance
Range 20/200MΩ
(Auto-ranging)
20/200/2000MΩ (Auto-ranging)
Open circuit
voltage (DC)
250V+25% -0% 500V+25% -0% 1000V+20% -0%
Rated current 1mA or greater
@ 250kΩ 
1mA or greater
@ 500kΩ
1mA or greater
@ 1MΩ
Accuracy ±2%rdg+6dgt
(0 - 19.99MΩ)
±5%rdg+6dgt
(20 - 200MΩ)
±2%rdg+6dgt (0 - 199.9MΩ)
±5%rdg+6dgt (200 - 2000MΩ)
Loop Impedance
Function L-PE L-PE (ATT) L-N / L-L
Rated Voltage 100 - 260V 50/60Hz L-N: 100 - 300V
L-L: 300 - 500V
50/60Hz
Nominal Test
Current at 0Ω
External Loop:
Magnitude/
Duration (*2)
20Ω: 6A/20ms
200Ω: 2A/20ms
2000Ω: 15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx. 5s
20Ω: 6A/20ms
Range 20/200/2000Ω
(Auto-ranging)
20/200/2000Ω
(Auto-ranging)
(L-N < 20Ω)
20Ω
Accuracy ±3%rdg+4dgt(*3)
±3%rdg+8dgt(*4)
±3%rdg+6dgt (*3)
±3%rdg+8dgt(*4)
±3%rdg+4dgt (*3)
±3%rdg+8dgt(*4)  
PSC (L-N / L-L) / PFC (L-PE)
Function PSC PFC PFC (ATT)
Rated Voltage 100 - 500V 50/60Hz 100 - 260V 50/60Hz  
Nominal Test
Current at 0Ω
External Loop:
Magnitude/
Duration (*5)
6A/20ms 6A/20ms
2A/20ms
15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx. 5s 
 Range 2000A/20kA Auto-Ranging
Accuracy PSC / PFC accuracy is derived from measured loop impedance
specification and measured voltage specification
RCD
Function X1/2 X1 X5 Ramp Auto
Trip current
setting
10/30/100/300/
500/1000mA
10/30/
100mA   
10/30/
100/300/
500mA
Depending on the
accuracy at each
function.
Measurement sequence:
X1/2 0°→X1/2 180°
→X1 0°→X1 180°
→X5 0°→X5 180°
Measurements with
x5 are not carried out
for RCDs with
nominal current of
100mA or more.
Trip current
Duration
2000ms G: 550ms
S: 1000ms
410ms Goes up by
10% from
20% to
110%
G:300ms/
S:500ms
X10 times
Rated Voltage 230V+10%-15% 50/60Hz
Accuracy AC Type:
-8% - -2%
A Type:
-10% - 0%
AC Type: +2% - +8%
A Type: 0% - +10%
AC Type: ±4%
A Type: ±10%
Trip time: ±1%rdg+3dgt
RCD (Uc)
Function UC
Rated Voltage 230V+10% - 15% 50/60Hz
Range 100.0V
Test current ≤ 1/2IΔn (max150mA)
Accuracy +5% - +15%rdg, ±8dgt
Earth
Range 20/200/2000Ω Auto-Ranging
Accuracy 20Ω: ±3%rdg+0.1Ω
200/2000Ω: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)
Phase Rotation
Rated Voltage 50-500V 50/60Hz
Remarks Correct phase sequence: are displayed "1.2.3" and  recycle mark
Reversed phase sequence: are displayed "3.2.1" and  recycle mark
Volts
Function Volts Frequency
Rated Voltage 25 - 500V, 45 - 65Hz
Measuring range  25 - 500V 45 - 65Hz
Accuracy ±2%rdg+4dgt ±0.5%rdg+2dgt
Applicable standards IEC 61010-1 CAT III 300V (500V L to L) Pollution degree 2, IEC 61010-031,
IEC 61557-1, 2, 3, 4, 5, 6, 7, 10, IEC 60529 (IP40), IEC 61326 (EMC)
Power source LR6 X 8
Dimensions 136(L) X 235(W) X 114(D)mm
Weight 1350g (including batteries.)
Included Accessories 7188A (Distribution board fuse test lead set)
7196A (Test leads with remote control switch)
7218A (Power cord [EU]) (*6)
7228A (Earth resistance test leads)
8032 (Auxiliary earth spikes)
8212-USB (USB adaptor with KEW Report (Software))
9142 (Carrying case)
9121 (Shoulder strap)
Cord case, Buckle, Battery, Instruction manual
Optional Accessories 8212-RS232C (RS232C adaptor with KEW Report (Software))

 

MODEL 6011A

Jual Multi Function Testers MODEL 6011A

 

Multi Function Testers

MODEL 6011A

MODEL 6011A
CE
 
• Complies with IEC 61557
• Designed to IP 54 Rating
• Live circuit and wiring connection check LED's
• Triple ranges insulation tests at 250, 500 and 1000V
• Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip)
• Phase angle selection on RCD ranges
• Polarity switch for continuity tests
• Auto-null facility for continuity tests
• Earth probe for loop impedance testing on extraneous metalwork
• Contact Voltage Reading
• Test of a large kind of RCD's: Standard, Selective, AC and A
(DC sensitive breakers)
 
Continuity Testing
Measuring Ranges 20/200/2000Ω (Autoranging)
Open Circuit Voltage >6V
Short Circuit Current >200mA DC
Accuracy ±(1.5%rdg+3dgt)
Insulation Testing
Measuring Ranges 20/200MΩ (Autoranging)
Test Voltage 250V 500V 1000V DC
Output Voltage on Open Circuit 250V+40%-0%
500V+30%-0%
1000V+20%-0%
Rated Current > 1mA
Accuracy ±(1.5%rdg+3dgt)
Loop Impedance Testing
Rated Voltage 230V AC +10%-15% [50Hz]
Voltage Measuring Range 100 - 250V AC [50Hz]
Impedance Ranges 20/200/2000Ω
Nominal Test Current 25A (20Ω range) 15mA (200Ω range) 15mA (2000Ω range)
Accuracy 20Ω range ±(3%rdg +4dgt)
200Ω range ±(3%rdg +8dgt)
2000Ω range ±(3%rdg +4dgt)
PSC Testing
Rated Voltage 230V AC +10%-15% [50Hz]
PSC Ranges 200A (15mA Test Current)
2000A (25A Test Current)
20kA (25A Test Current)
Accuracy PSC accuracy derived from measured loop impedance specification
and measured voltage specification
RCD Testing
Rated Voltage 230V AC +10%-15% [50Hz]
Trip Current Settings RCD × 1/2 : 10,30,100,300,500,1000mA
RCD × 1 : 10,30,100,300,500,1000mA
RCD × 5 : 10,30,100,300mA (on × 5 ranges max current 1A)
Trip Current Duration RCD × 1/2 × 1: 2000ms
RCD fast: 50ms
Accuracy Trip current +10%-0% of test current at 230V
Trip time ±(1%rdg + 3dgt)
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61557
Power source LR6 (1.5V) × 8
Dimensions 130(L) × 183(W) × 100(D)mm
Weight 1100g approx.
Included Accessories *KAPM10
(Molded plug test leads for loop and RCD testing at sockets)
7122B (Test leads)
7132A (External earth probe)
Pouch for Test Leads
9121 (Shoulder Strap)
Battery LR6 (1.5V) × 8
Instruction Manual
Optional Accessories 7133B (Distribution board test leads)

 

KEW 6010B

Jual Multi Function Testers KEW 6010B

 

Multi Function Testers

KEW 6010B

KEW 6010B
CE
 
• Continuity:20/200Ω 200mA Test Current
• Insulation: 500/1000V, 20/200MΩ 1mA Rated Test Current
• Loop Impedance:20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)
• RCD:10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
• Test of a large kind of RCD's:Standard, Selective, AC and A(DC sensitive breakers)
• Uc(Contact Voltage): 100V
• Designed to IEC 61010-1, IEC 61557
• Data Memory:300 measured results
• The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.
 
Continuity Testing
Measuring Range 20/200Ω (Auto-Ranging)
Open Circuit Voltage > 6V
Short Circuit Current > 200mA
Accuracy ±(3%rdg + 3dgt)
Insulation Resistance Testing
Measuring Range 20/200MΩ (Auto-Ranging)
Test Voltage 500/1000V
Open Circuit Voltage +20% - 0%
Rated Current > 1mA
Accuracy ± (3%rdg + 3dgt)
Loop Impedance Testing
Impedance Range 20/2000Ω
Rated Voltage 230V + 10% - 15%(50Hz)
Normal Test Current 20Ω:25A/10ms
2000Ω:15mA/350ms max.
Accuracy ±(3%rdg + 8dgt)
RCD Testing
Test Current
(Test Current Duration)
x1/2, x1 10, 30, 100, 300, 500mA (2000ms)
Fast 150mA (50ms)
DC 10, 30, 100, 300mA (2000ms), 500mA (200ms)
Auto Ramp Goes up by 10% from 20% to 110% of IΔn. 300ms×10
Rated Voltage 230V + 10% - 15% 50Hz
AccuracyTest Current x1/2: -8%-2%
x1, FAST: +2%+8%
DC: ±10%
Auto Ramp: ±4%
Trip Time ±(1%rdg + 3dgt)
Uc Testing
Measuring Range 100V
Rated Voltage 230V + 10% - 15% (50Hz)
Test Current 5mA at IΔn = 10mA
15mA at IΔn = 30/100mA
150mA at IΔn = 300/500mA
Accuracy +5%+15%rdg, ±8dgt
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)
Power source R6 or LR6 × 8
Dimensions 175(L) × 115(W) × 86(D)mm
Weight 840g approx.
Included Accessories 7122B (Test leads)
KAMP10* (Test Lead with IEC Connector)
Pouch for Test leads
Shoulder Strap
Shoulder Pad
Instruction Manual
Optional Accessories 7133B (Distribution board test leads)
8212-RS232C (RS232C adaptor with "KEW Report (Software)")