MODEL 2010

AC/DC Digital Clamp Meters

MODEL 2010

 

MODEL 2010
 
• High sensitivity, miniature AC/DC clamp meter.
• 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
• Output terminal for recorder connection.

φ7.5 DCACA MAX20A OutPut External

Never make current measurement on a circuit above 60V AC/DC
as the instrument is designed for use on low voltage circuits only.

 

AC A 200mA/2/20A
±1%rdg±2dgt [50/60Hz] (200mA)
±1.5%rdg±4dgt [40Hz - 2kHz] (200mA)
±1%rdg±2dgt [50/60Hz] (2A)
±2.5%rdg±5dgt [40Hz - 2kHz] (2/20A)
DC A 2/20A
±1%rdg±2dgt (2A)
±1.5%rdg±4dgt (20A)
Conductor size Ø7.5mm max.
Frequency response DC, 40Hz - 2kHz
Output Recorder :
DC200mV against AC200mA/2/20A
DC200mV against DC2/20A
Power source 6LF22(9V) × 1 or AC Adaptor
Dimensions 142(L) × 64(W) × 26(D)mm
153(L) × 23(W) × 18(D)mm
Clamp Sensor
Weight 220g approx.
Included Accessories 9071 (Carrying Case)
Alkaline 6LF22 × 1
Instruction Manual
Optional Accessories 8022 (AC Adaptor) (110V)
8023 (AC Adaptor) (220V)
7256 (Output cord)

 

KEW 2009R

AC/DC Digital Clamp Meters

KEW 2009R

 

KEW 2009R
CE
 
• CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
• Accurate True-RMS reading of AC current or voltage with distorted waveform.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.

TRUE RMS CAT4 600V φ55 MAX2000A DCACA DCACV Resistance Continuitybuzzer FrequencyDATAHOLD PeakHold10ms OutPut AutoPowerOff

 

 

AC A 400.0/2000A
±1.3%rdg±3dgt (0 - 400.0A, 150 - 1700A) (45 - 66Hz)
±2.0%rdg±5dgt (0 - 400.0A, 150 - 1700A) (20Hz - 1kHz)
±2.3%rdg±3dgt (1701 - 2000A) (45 - 66Hz)
DC A 400.0/2000A±1.3%rdg±2dgt
AC V 40.00/400.0/750V
±1.0%rdg±3dgt (45 - 66Hz)
±1.5%rdg±5dgt (20Hz - 1kHz)
DC V 40.00/400.0/1000V±1.0%rdg±2dgt
Ω 400.0/4000Ω ±1.5%rdg±2dgt
(Electronic protection (no fuse) up to 600V)
Continuity buzzer Buzzer sounds below 20Ω
Hz 10.0 - 4000Hz±1.5%rdg±5dgt
(Input sensitivityCurrent: more than 40AVoltage: more than 10V)
Conductor size Ø55mm max.
Output Recorder :
DC400mV against AC/DC400.0A
DC200mV against AC/DC2000A
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1
Power source R6 (1.5V) × 2
Dimensions 250(L) × 105(W) × 49(D)mm
Weight Approx. 540g (including batteries)
Included Accessories 7107A (Test leads), 8201 (Output plug), 9094 (Carrying case)
R6 (AA) (1.5V) × 2, Instruction Manual
Optional Accessories 8008 (Multi-Tran) (AC only), 7256 (Output cord)

 

KEW 2003A

AC/DC Digital Clamp Meters

KEW 2003A

 

KEW 2003A
CE
 
• Equipped to measure both AC and DC current with transformer jaws of large diameter.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.

CAT4 600V φ55 MAX2000A DCACA DCACV Resistance Continuitybuzzer DATAHOLD OutPut AutoPowerSave

 

 

 

AC A 400A/2000A (0 - 1000A)
±1.5%rdg±2dgt [50/60Hz]
±3%rdg±4dgt [40 - 500Hz]
±5%rdg±4dgt [500Hz - 1kHz]
2000A (1001 - 2000A)
±3%rdg±2dgt [50/60Hz]
DC A 400/2000A ±1.5%rdg±2dgt
AC V 400/750V
±1.5%rdg±2dgt [50/60Hz]
±1.5%rdg±4dgt [40Hz - 1kHz]
DC V 400/1000V ±1%rdg±2dgt
Ω 400/4000Ω ±1.5%rdg±2dgt
Continuity buzzer buzzer sounds below 50±35Ω
Conductor size Ø55mm max.
Frequency response 40Hz - 1kHz
Output Recorder :
DC400mV against AC/DC400A
DC200mV against AC/DC2000A
Safety Standard IEC 61010-1 CAT IV 600V , CAT III 1000V
IEC 61010-031
IEC 61010-2-032
Power source R6 (AA) (1.5V) × 2
Dimensions 250(L) × 105(W) × 49(D)mm
Weight 530g approx.
Included Accessories 7107A (Test leads)
8201 (Output Plug)
9094 (Carrying Case)
R6 (AA) × 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran) (AC only)
7256 (Output cord)