Home  //  Products  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 4202

Jual Earth Clamp Testers KEW 4202

 

Earth Clamp Testers

KEW 4202

KEW 4202
CE
Various useful functions are available on Android devices using Bluetooth communication
• Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)
• Saved data includes measurement, GPS location and date & time Easy to check on map "When" and "Where" the measurement was made
• Comparator function on Android device informs when the measured value is lower/higher than the preset value

Earth /Ground resistance and Leakage current measurement functions
• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems
• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks
• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments
  • TRUE RMS φ32 Backlight Bluetooth

Free Android software "KEW smart 4202"
is available on "Google Play Store"(*)

<System requirement>
• Supporting Android ver. 2.2 - 4.4
• WVGA (800 × 480) resolution or higher
• GPS function

(*)Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.

Earth resistance Auto range 20.00/200.00/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)
AC current (50Hz/60Hz) Auto range Values are displayed, but accuracy isn't guaranted(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)
Operating indication Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication "OL"is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)
Sample rate Approx. 1 times per second
Communication Interface Bluetooth Ver2.1 + EDR Class2
Current consumption Approx. 50mA (max.100mA)
Measurement time Approx.5 hours (when R6 is used) Approx. 21 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.
Conductor size Approx.Ø32mm
Applicable standards IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions 246(L)×120(W)×54(D)mm
Weight Approx. 780g (including batteries)
Included Accessories LR6 x 4, Instruction manual
8304 (Resister for operation check)
9167 (Carrying case[Hard])

MODEL 4200

Jual Earth Clamp Testers MODEL 4200

 

Earth Clamp Testers

MODEL 4200

MODEL 4200
CE
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.
• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2

Note:
A single earthing can not be measured. (Only for Multiple Earthing System)
  • TRUE RMS φ32 Backlight

Earth resistance Auto range 20.00/200.0/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)*
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)
AC current (50Hz/60Hz) Auto range Values are displayed, but accuracy isn't guaranted(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)
Operating indication Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication "OL"is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)
Sample rate Approx. 1 times per second
Current consumption Approx. 50mA (max.100mA)
Measurement time Approx.12 hours (when R6 is used)
Approx.24 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.
Conductor size Approx. Ø32mm
Applicable standards IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions 246(L)×120(W)×54(D)mm
Weight Approx. 780g (including batteries)
Included Accessories R6 x 4, Instruction manual
8304 (Resister for operation check)
9166 (Carrying case[Hard])

KEW 4106

Jual Earth Resistance & Resistivity Tester KEW 4106

 

Earth Resistance & Resistivity Tester

KEW 4106

KEW 4106
CE
Earth Resistance & Resistivity Tester
• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
  • Backlight
 
FunctionRangeResolutionMeasuring rangeAccuracy
Earth resistance
Re
(Rg at
ρ measurement)
2Ω 0.001Ω 0.03 - 2.099Ω ±2%rdg±0.03Ω
20Ω 0.01Ω 0.03 - 20.99Ω ±2%rdg±5dgt (*1)
200Ω 0.1Ω 0.3 - 209.9Ω
2000Ω 1Ω 3 - 2099Ω
20kΩ 10Ω 0.03k - 20.99kΩ
200kΩ 100Ω 0.3k - 209.9kΩ
Auxiliary earth resistance
Rh, Rs
      8% of Re+Rh+Rs
Earth resistivity
ρ
2Ω 0.1Ω·mm - 1Ω·m
Autoranging
0.2 - 395.6Ω·m ρ=2×π×a×Rg (*2)
20Ω 0.2 - 3956Ω·m
200Ω 20 - 39.56kΩ·m
2000Ω 0.2 - 395.6kΩ·m
20kΩ 2.0 - 1999kΩ·m
200kΩ
Series interference voltage
Ust (A.C only) (*3)
50V 0.1V 0 - 50.9Vrms ±2%rdg±2dgt (50/60Hz)
±3%rdg±2dgt (40 - 500Hz)
Frequency
Fst
Autoranging 0.1Hz
1Hz
40Hz - 500Hz ±1%rdg±2dgt
Measuring method Earth resistance: Fall-of-potential method
(currents and voltages measured via the Probes)
Measurement method of Earth Resistivity (ρ): Wenner 4-pole method
Series interference voltage (earth voltage)
RMS Rectifier (between the E-S Terminals)
Memory capacity 800 data
Communication Interface Model 8212-USB Optical Adaptor
LCD Dot-matrix 192×64 monochrome
Over-range Indication "OL"
Overload Protection between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Applicable standards IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
Power source DC12V : sizeAA manganese dry battery (R6) × 8
(Auto power off: approx. 5 minutes)
Dimensions 167(L) × 185(W) × 89(D) mm
Weight approx. 900g (including batteries)
Accessories 7229A (Earth precision measurement),
7238A (Simplified measurement test leads),
8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),
8200-04 (Cord reel [4 pcs])×1 set,
8212-USB (USB adaptor with "KEW Report(Software)"),
9121 (Shoulder strap),
9125 (Carrying case),
R6 × 8, Instruction manual, Calibration certificate
Optional 8212-RS232C (RS232C adaptor with "KEW Report(Software)")