Home  //  Products  //  Clamp Meters
  • Email us at : sales@kyoritsuindonesia.com

Kyoritsu Indonesia - Jual Kyoritsu

DC Milliamp Clamp Meter

KEW 2500

KEW 2500

• 0.01mA resolution for DC current
• Top class measurement 0.2% accuracy
• Ø6mm clamp jaw easy to use in tight places
• Measurement from 0.01mA to 120.0mA
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span
• Spotlight for illuminating measurement point
• Analog output terminal for recorder connection
• Complies with IEC 61010-1 CAT II 300V

φ6 DCA Backlight DATAHOLD AutoPowerOff OutPut

DC Milliamp Clamp Logger

  • KEW 2510

    KEW 2510NEW

    • Measures 4 to 20 mA instrumentation and process signals without breaking the loop
    • Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding
    • Transfer data to PC via Bluetooth
    • Top class measurement 0.2% accuracy
    • ∅6mm clamp jaw easy to use in tight places
    • LED light for illuminating the measurement spot
    • Analog output terminal to allow the connection to a recorder or a digital multimeter

    φ6 DCA Backlight DATAHOLD AutoPowerOff OutPut Bluetooth External

AC Digital Clamp Meters

  • KEW 2007R

    KEW 2007RNEW

    • Fully Safety jaw
    • Ergonomic over-molded body gives convenient one-hand operation
    • Large easy-to-read display with 0.1A resolution
    • Accurate reading with True RMS
     600/1000A auto-ranging
    • Long battery life
    • Safety Standard
      IEC 61010-1 CAT IV 300V / CAT III 600V

    TRUE RMS CAT4 300V CAT3 600V φ33 MAX1000A ACA DCACV Resistance Continuitybuzzer DATAHOLD AutoPowerSave
    • KEW 2117R

      KEW 2117RNEW

      • Fully Safety jaw
      • Ergonomic over-molded body gives convenient one-hand operation
      • Large easy-to-read display with 0.01A resolution
      • Accurate reading with True RMS
      60/600/1000A auto-ranging
      • Long battery life
      • Safety Standard
      IEC 61010-1 CAT IV 300V / CAT III 600V

      TRUE RMS CAT4 300V CAT3 600V φ33 MAX1000A ACA DCACV NCV Resistance Continuitybuzzer DATAHOLD AutoPowerSave
      • KEW 2200R

        KEW 2200RNEW

        • Ultra slim and lightweight Handy design
        • Ø33mm Tear Drop Jaw easy to use in tight places
        • 1000A AC Clamp Meter
        • DMM function ACV, DCV, Ω, Continuity Buzzer
        • Fuseless electronic protection on "Ω/Continuity Buzzer" up to 600V
        • Safety Standard
        IEC 61010-1, 61010-2-032 CAT IV 300V / CAT III 600V

        TRUE RMS φ33 MAX1000A ACA DCACV Resistance Continuitybuzzer DATAHOLD AutoPowerOff
        •  KEW 2204R

          KEW 2204RNEW

          • Flexible and light weight clamp sensor
          • MIN MAX function
          • Backlight LCD display
          • IEC 61010-1 (CAT IV 600V /CAT III 1000V)
          • True RMS

          TRUE RMS CAT4 600V φ70 MAX400A ACA AutoPowerOff MAX/MIN DATAHOLD Backlight
          •  MODEL 2002PA

            MODEL 2002PA

            • Can measure large AC current up to 2000A.
            • Peak hold function.
            • 55mm-dia large tear drop shaped jaws.

            φ55 MAX2000A ACV DCV Resistance PeakHold10ms OutPut Continuitybuzzer
            • MODEL 2002R

              MODEL 2002R

              • Can measure large AC current up to 2000A.
              • Peak hold function.
              • 55mm-dia large tear drop shaped jaws.

              TRUE RMS φ55 MAX2000A ACV DCV Resistance PeakHold10ms OutPut Continuitybuzzer
              • MODEL 2017

                MODEL 2017

                • Tear drop shaped jaws for ease of use in tight places and crowded cable areas.
                • Designed to meet internationally proven safety standards such as IEC 61010-1, UL3111 and VDE0411.
                • Three functions in one unit; AC current, AC voltage and resistance.
                • Resistance range provides audible continuity test.
                • Frequency response from 40Hz to 1kHz on AC current and voltage ranges.

                φ33 MAX600A ACA ACV Resistance Continuitybuzzer DATAHOLD
                •  MODEL 2027

                  MODEL 2027

                  • True RMS reading instrument that permits precise measurements of nonsinusoidal waveform AC current and voltage. Accurate measurements are also possible at low frequencies from 10Hz upwards.
                  • Designed to meet internationally proven safety standards such as
                  IEC 61010-1, UL3111 and VDE0411.
                  • Three functions in one unit; AC current, AC voltage and resistance.

                  TRUE RMS φ33 MAX600A ACV Resistance Continuitybuzzer DATAHOLD
                  • MODEL 2031

                    MODEL 2031

                    • Can measure large AC current up to 200A.
                    • 24mm-dia tear drop shaped jaws.

                    φ24 MAX200A ACA DATAHOLD AutoPowerOff
                    • KEW 2040

                      KEW 2040

                      • Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
                      • CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
                      • Thus, very useful for power distribution companies, power utilities and maintenance fields.

                      CAT4 600V φ33 MAX600A ACA DCACV Resistance Continuitybuzzer Frequency DUTY MAX/MIN Relative
                      • KEW 2200

                        KEW 2200

                        The Slim and Lightweight 1000A AC Clamp Meter

                        φ33 MAX1000A ACA DCACV Resistance Continuitybuzzer DATAHOLD AutoPowerOff
                        • KEW 2210R

                          KEW 2210R

                          • Flexible and light weight clamp sensor
                          • Wide reading range up to 3000A
                          • True RMS
                          • MIN MAX function
                          • Backlight LCD display
                          • IEC 61010-1 (CAT IV 600V / CAT III 1000V)

                          TRUE RMS CAT4 600V φ150 MAX3000A ACA Backlight DATAHOLD MAX/MIN AutoPowerOff

AC Analogue Clamp Meters

  • MODEL 2608A

    MODEL 2608A

    • DC voltage range is also available especially for checking emergency battery operated power supply.
    • Can measure temperature using optional probe.
    • Tear drop shaped transformer jaws for ease of use.

    φ33 MAX300A Temperature ACA DCACV Resistance DATAHOLD

AC/DC Digital Clamp Meters

  • KEW 2003A

    KEW 2003A

    • Equipped to measure both AC and DC current with transformer jaws of large diameter.
    • Can measure AC and DC currents up to 2000A.
    • Output terminal for connection to recorders.

    CAT4 600V φ55 MAX2000A DCACA Resistance Continuitybuzzer DATAHOLD OutPut AutoPowerSave
    • KEW 2009R

      KEW 2009R

      • CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
      • Accurate True-RMS reading of AC current or voltage with distorted waveform.
      • Can measure AC and DC currents up to 2000A.
      • Output terminal for connection to recorders.

      TRUE RMS CAT4 600V φ55 MAX2000A DCACA Resistance Continuitybuzzer Frequency DATAHOLD PeakHold10msOutPut AutoPowerOff
      • MODEL 2010

        MODEL 2010

        • High sensitivity, miniature AC/DC clamp meter.
        • 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
        • Output terminal for recorder connection.

        φ7.5 DCACA MAX20A OutPut External
        • MODEL 2033

          MODEL 2033

          • Smallest clamp meter capable of AC and DC current measurements.
          • 300A auto ranging has minimum resolution of 0.01A AC/DC.
          • Auto-zero function to allow one touch zero adjustment.

          φ24 MAX300A DCACA DATAHOLD AutoPowerSave
          • KEW 2046R

            KEW 2046R

            • Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
            • CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
            • Very useful for power distribution companies, power utilities and maintenance fields.
            • True RMS enables an accurate measurement.

            TRUE RMS CAT4 600V φ33 MAX600A ACV DCV Resistance Continuitybuzzer Frequency DUTY Diode Capacitance Temperature Backlight DATAHOLDPeakHold10ms MAX/MIN AutoPowerOff
            •  KEW 2055

              KEW 2055

              • Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
              • CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
              • Very useful for power distribution companies, power utilities and maintenance fields.

              CAT4 600V φ40 MAX1000A DCACV DCACA Resistance Continuitybuzzer Frequency DUTY Backlight DATAHOLD MAX/MIN Relative AutoPowerSave
              • KEW 2056R

                KEW 2056R

                • Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
                • CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
                • Very useful for power distribution companies, power utilities and maintenance fields.
                • True RMS enables an accurate measurement.

                TRUE RMS CAT4 600V φ40 MAX1000A DCACV DCACA Resistance Continuitybuzzer Frequency DUTY Diode Capacitance Temperature Backlight DATAHOLD PeakHold10ms MAX/MIN Relative AutoPowerOff

Fork Current Tester

  • MODEL 2300R

    MODEL 2300R

    • True RMS reading is an essential feature for accurate measurement.
    • “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
    • Set the DC current range to zero in one touch with the Zero Adjust function.

    TRUE RMS φ10 MAX100A DCACA DATAHOLD AutoPowerOff

Leakage Clamp Meters

  • MODEL 2412

    MODEL 2412

    • Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
    • Frequency filter switch to eliminate the effect of harmonics.
    • Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.
    • Resolution 0.01mA.

    φ40 MAX500A ACV Resistance OutPut Filter External
    • KEW 2413F

      KEW 2413F

      • Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
      • Frequency filter switch to eliminate the effect of harmonics.
      • Output terminal.
      • Resolution 0.1mA.

      φ68 MAX1000A ACA DATAHOLD PeakHold10/100ms OutPut Filter
      • KEW 2413R

        KEW 2413R

        • Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
        • True RMS enables an accurate measurement for distorted waveforms.
        • Measurement from mA up to AC 1000A
        • Frequency filter switch to eliminate the effect of the harmonics.
        • 2 way analogue output terminal
        • Resolution 0.1mA

        TRUE RMS φ68 MAX1000A ACA DATAHOLD PeakHold10/100ms OutPut Filter Backlight
        • MODEL 2431

          MODEL 2431

          • Frequency Selector Switch to eliminate the effect of harmonics.
          • Three AC current ranges 20mA/200mA/200A.
          • Rotary switch for easy one finger power-on and range selection.
          • Resolution 0.01mA.

          φ24 MAX200A Filter
          • MODEL 2432

            MODEL 2432

            • High Sensitive Model
            • Frequency Selector Switch to eliminate the effect of harmonics.
            • Three AC current ranges:4mA/40mA/100A.
            • Resolution 0.001mA.

            φ40 MAX100A Filter PeakHold10ms
            • MODEL 2433

              MODEL 2433

              • Frequency Selector Switch to eliminate the effect of harmonics.
              • Three AC current ranges:40mA/400mA/400A.
              • Resolution 0.01mA.

              φ40 MAX400A Filter PeakHold10ms
              • MODEL 2433R

                MODEL 2433R

                • Frequency Selector Switch to eliminate the effect of harmonics.
                • Three AC current ranges:40mA/400mA/400A.
                • Resolution 0.01mA.

                TRUE RMS φ40 MAX400A ACA DATAHOLD PeakHold10ms Filter AutoPowerOff
                • MODEL 2434

                  MODEL 2434

                  • Least affected by external stray magnetic field.
                  • 20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
                  • Frequency Selector Switch to eliminate the effect of harmonics.
                  • Resolution 0.1mA.

                  φ28 MAX100A Filter
148993
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
62
210
1328
146058
3450
3625
148993

Your IP: 54.221.75.115