• 0.01mA resolution for DC current
• Top class measurement 0.2% accuracy
• Ø6mm clamp jaw easy to use in tight places
• Measurement from 0.01mA to 120.0mA
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span
• Spotlight for illuminating measurement point
• Analog output terminal for recorder connection
• Complies with IEC 61010-1 CAT II 300V


• Measures 4 to 20 mA instrumentation and process signals without breaking the loop
• Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding
• Transfer data to PC via Bluetooth
• Top class measurement 0.2% accuracy
• ∅6mm clamp jaw easy to use in tight places
• LED light for illuminating the measurement spot
• Analog output terminal to allow the connection to a recorder or a digital multimeter


• Fully Safety jaw
• Ergonomic over-molded body gives convenient one-hand operation
• Large easy-to-read display with 0.1A resolution
• Accurate reading with True RMS
600/1000A auto-ranging
• Long battery life
• Safety Standard
IEC 61010-1 CAT IV 300V / CAT III 600V


• Fully Safety jaw
• Ergonomic over-molded body gives convenient one-hand operation
• Large easy-to-read display with 0.01A resolution
• Accurate reading with True RMS
60/600/1000A auto-ranging
• Long battery life
• Safety Standard
IEC 61010-1 CAT IV 300V / CAT III 600V


• Ultra slim and lightweight Handy design
• Ø33mm Tear Drop Jaw easy to use in tight places
• 1000A AC Clamp Meter
• DMM function ACV, DCV, Ω, Continuity Buzzer
• Fuseless electronic protection on "Ω/Continuity Buzzer" up to 600V
• Safety Standard
IEC 61010-1, 61010-2-032 CAT IV 300V / CAT III 600V


• Flexible and light weight clamp sensor
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V /CAT III 1000V)
• True RMS

• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large tear drop shaped jaws.

• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large tear drop shaped jaws.

• Tear drop shaped jaws for ease of use in tight places and crowded cable areas.
• Designed to meet internationally proven safety standards such as IEC 61010-1, UL3111 and VDE0411.
• Three functions in one unit; AC current, AC voltage and resistance.
• Resistance range provides audible continuity test.
• Frequency response from 40Hz to 1kHz on AC current and voltage ranges.

• True RMS reading instrument that permits precise measurements of nonsinusoidal waveform AC current and voltage. Accurate measurements are also possible at low frequencies from 10Hz upwards.
• Designed to meet internationally proven safety standards such as
IEC 61010-1, UL3111 and VDE0411.
• Three functions in one unit; AC current, AC voltage and resistance.

• Can measure large AC current up to 200A.
• 24mm-dia tear drop shaped jaws.

• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Thus, very useful for power distribution companies, power utilities and maintenance fields.

The Slim and Lightweight 1000A AC Clamp Meter

• Flexible and light weight clamp sensor
• Wide reading range up to 3000A
• True RMS
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V / CAT III 1000V)

• DC voltage range is also available especially for checking emergency battery operated power supply.
• Can measure temperature using optional probe.
• Tear drop shaped transformer jaws for ease of use.

• Equipped to measure both AC and DC current with transformer jaws of large diameter.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.

• CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
• Accurate True-RMS reading of AC current or voltage with distorted waveform.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.

• High sensitivity, miniature AC/DC clamp meter.
• 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
• Output terminal for recorder connection.

• Smallest clamp meter capable of AC and DC current measurements.
• 300A auto ranging has minimum resolution of 0.01A AC/DC.
• Auto-zero function to allow one touch zero adjustment.

• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.

• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.

• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.

• True RMS reading is an essential feature for accurate measurement.
• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
• Set the DC current range to zero in one touch with the Zero Adjust function.

• Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.
• Resolution 0.01mA.

• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal.
• Resolution 0.1mA.

• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables an accurate measurement for distorted waveforms.
• Measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2 way analogue output terminal
• Resolution 0.1mA

• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges 20mA/200mA/200A.
• Rotary switch for easy one finger power-on and range selection.
• Resolution 0.01mA.

• High Sensitive Model
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA.

• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.

• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.

• Least affected by external stray magnetic field.
• 20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC
• Frequency Selector Switch to eliminate the effect of harmonics.
• Resolution 0.1mA.

| AC A (50/60Hz) | 400mA/4/100A ±2%rdg±4dgt |
|---|---|
| AC A (WIDE) | 400mA/4/100A ±2%rdg±4dgt [50/60Hz] ±3%rdg±5dgt [40 - 400Hz] |
| Conductor size | Ø28mm max. |
| Frequency response | 40 - 400Hz |
| Effect of external stray magnetic field φ15mm 100A | 20mA AC max. |
| Safety Standard | IEC 61010-1 CAT III 300V IEC 61010-2-032 |
| Power source | R03 (AAA) (1.5V) × 2 |
| Dimensions | 169(L) × 75(W) × 40(D)mm |
| Weight | 220g approx. |
| Included Accessories | 9097 Carrying Case R03 × 2 Instruction Manual |
| Optional Accessories | 8008 (Multi-Tran)* |