JUAL PRODUK ROHDE & SCHWARZ

Jual Rohde and Schwarz dengan harga murah dan bergaransi

JUAL PRODUK FLIR INDONESIA HARGA MURAH

Jual Produk Flir dengan harga murah

Jual Anritsu Indonesia

Jual Anritsu dengan harga murah dan bergaransi resmi

Jual Keithley, Keithley Indonesia, Distributor Keithley, Harga Keithley, Keithley Murah

Jual Tekiro - Tekiro Indonesia

Distributor Tekiro Indonesia, Harga Tekiro, Tekiro Murah

Kikusui Indonesia - Ametek Indonesia

Kikusui Indonesia - Ametek Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Jual Alat Safety Indonesia

Jual Alat Safety Indonesia, Yotsugi Indonesia, Respirex Indonesia, Regeltex Indonesia, Bushnell Indonesia

Jual Ritz Telescopic Hot Stick - Sensorlink

Jual Ritz Telescopic Hot Stick ,Jual Sensorlink Indonesia dengan harga murah
Home  //  Others  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

MODEL 2431

Leakage Clamp Meters

MODEL 2431

 

MODEL 2431
CE
 
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges 20mA/200mA/200A.
• Rotary switch for easy one finger power-on and range selection.
• Resolution 0.01mA.

φ24 MAX200A Filter

 

 

AC A (50/60Hz) 20/200mA/200A
±3%rdg±5dgt (20/200mA/100A)
±5%rdg±5dgt (200A)
AC A (WIDE) 20/200mA/200A
±2%rdg±4dgt [50/60Hz] (20/200mA/0 - 100A)
±5%rdg±6dgt [40 - 400Hz] (20/200mA/0 - 100A)
±5%rdg±4dgt [50/60Hz] (100.1 - 200A)
Conductor size Ø24mm max.
Frequency response 40 - 400Hz
Effect of external stray magnetic field φ15mm 100A 10mA AC max.
Safety Standard IEC 61010-1 CAT III 300V
IEC 61010-2-032
Power source LR-44 (1.5V)× 2
Dimensions 149(L)× 60(W) × 26(D)mm
Weight 120g approx.
Included Accessories 9090 (Carrying Case)
LR-44 × 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*

 

KEW 2413R

Leakage Clamp Meters

KEW 2413R

 

KEW 2413R
CE
 
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables an accurate measurement for distorted waveforms.
• Measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2 way analogue output terminal
• Resolution 0.1mA

TRUE RMS φ68 MAX1000A ACA DATAHOLD PeakHold10/100ms OutPut Filter Backlight

 

 

AC A (50/60Hz) 200mA/2/20/200/1000A
±2.5%rdg±5dgt (200mA/2/20A)
±3.0%rdg±5dgt (200A, 0 - 500A)
±5.5%rdg (501 - 1000A)
AC A (WIDE) 200mA/2/20/200/1000A
±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A)
±2.0%rdg±5dgt (50/60Hz) (200A, 0 - 500A)
±5.0%rdg (50/60Hz) (501 - 1000A)
Crest factor 3.0 or less
Conductor size Ø68mm max.
Frequency response 40Hz - 1kHz
Output Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-2-032
Power source 6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours
Dimensions 250(L) × 130(W) × 50(D)mm
Weight Approx. 570g (including battery)
Included Accessories 9094 (Carrying Case)
6F22 × 1
Instruction Manual
Optional Accessories 7073 (2WAY Output Cord)

 

KEW 2413F

Leakage Clamp Meters

KEW 2413F

 

KEW 2413F
CE
 
• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal.
• Resolution 0.1mA.

φ68 MAX1000A ACA DATAHOLD PeakHold10/100ms OutPut Filter

 

 

AC A (50/60Hz) 200mA/2/20/200A/1000A
±1.5%rdg±2dgt (200mA/2/20A)
±2%rdg±2dgt (200A 0 - 500A)
±5.5%rdg (501 - 1000A)
AC A (WIDE) 200mA/2/20/200/1000A
±1%rdg±2dgt [50/60Hz],
±3%rdg±2dgt [40Hz - 1kHz] (200mA/2/20A)
±1.5%rdg±2dgt [50/60Hz],
±3.5%rdg±2dgt [40Hz - 1kHz] (200A/0 - 500A)
±5%rdg [50/60Hz],
±10%rdg [40Hz - 1kHz] (501 - 1000A)
Conductor size Ø68mm max.
Frequency response 40Hz - 1kHz
Effect of external stray magnetic field φ15mm 100A 10mA AC max.
Output Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Applicable standards IEC 61010-1 CAT III 300V
IEC 61010-2-032
Power source 6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours
Dimensions 250(L) × 130(W) × 50(D)mm
Weight 570g approx.
Included Accessories 9094 (Carrying Case)
6F22 × 1
Instruction Manual
Optional Accessories 7073 (2WAY Output Cord)

 