Never make current measurement on a circuit above 60V AC/DC
as the instrument is designed for use on low voltage circuits only.
| AC A | 200mA/2/20A ±1%rdg±2dgt [50/60Hz] (200mA) ±1.5%rdg±4dgt [40Hz - 2kHz] (200mA) ±1%rdg±2dgt [50/60Hz] (2A) ±2.5%rdg±5dgt [40Hz - 2kHz] (2/20A) |
|---|---|
| DC A | 2/20A ±1%rdg±2dgt (2A) ±1.5%rdg±4dgt (20A) |
| Conductor size | Ø7.5mm max. |
| Frequency response | DC, 40Hz - 2kHz |
| Output | Recorder : DC200mV against AC200mA/2/20A DC200mV against DC2/20A |
| Power source | 6LF22(9V) × 1 or AC Adaptor |
| Dimensions | 142(L) × 64(W) × 26(D)mm 153(L) × 23(W) × 18(D)mm Clamp Sensor |
| Weight | 220g approx. |
| Included Accessories | 9071 (Carrying Case) Alkaline 6LF22 × 1 Instruction Manual |
| Optional Accessories | 8022 (AC Adaptor) (110V) 8023 (AC Adaptor) (220V) 7256 (Output cord) |


| AC A | 400.0/2000A ±1.3%rdg±3dgt (0 - 400.0A, 150 - 1700A) (45 - 66Hz) ±2.0%rdg±5dgt (0 - 400.0A, 150 - 1700A) (20Hz - 1kHz) ±2.3%rdg±3dgt (1701 - 2000A) (45 - 66Hz) |
|---|---|
| DC A | 400.0/2000A±1.3%rdg±2dgt |
| AC V | 40.00/400.0/750V ±1.0%rdg±3dgt (45 - 66Hz) ±1.5%rdg±5dgt (20Hz - 1kHz) |
| DC V | 40.00/400.0/1000V±1.0%rdg±2dgt |
| Ω | 400.0/4000Ω ±1.5%rdg±2dgt (Electronic protection (no fuse) up to 600V) |
| Continuity buzzer | Buzzer sounds below 20Ω |
| Hz | 10.0 - 4000Hz±1.5%rdg±5dgt (Input sensitivityCurrent: more than 40AVoltage: more than 10V) |
| Conductor size | Ø55mm max. |
| Output | Recorder : DC400mV against AC/DC400.0A DC200mV against AC/DC2000A |
| Applicable standards | IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2 IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1 |
| Power source | R6 (1.5V) × 2 |
| Dimensions | 250(L) × 105(W) × 49(D)mm |
| Weight | Approx. 540g (including batteries) |
| Included Accessories | 7107A (Test leads), 8201 (Output plug), 9094 (Carrying case) R6 (AA) (1.5V) × 2, Instruction Manual |
| Optional Accessories | 8008 (Multi-Tran) (AC only), 7256 (Output cord) |

| AC A | 400A/2000A (0 - 1000A) ±1.5%rdg±2dgt [50/60Hz] ±3%rdg±4dgt [40 - 500Hz] ±5%rdg±4dgt [500Hz - 1kHz] 2000A (1001 - 2000A) ±3%rdg±2dgt [50/60Hz] |
|---|---|
| DC A | 400/2000A ±1.5%rdg±2dgt |
| AC V | 400/750V ±1.5%rdg±2dgt [50/60Hz] ±1.5%rdg±4dgt [40Hz - 1kHz] |
| DC V | 400/1000V ±1%rdg±2dgt |
| Ω | 400/4000Ω ±1.5%rdg±2dgt |
| Continuity buzzer | buzzer sounds below 50±35Ω |
| Conductor size | Ø55mm max. |
| Frequency response | 40Hz - 1kHz |
| Output | Recorder : DC400mV against AC/DC400A DC200mV against AC/DC2000A |
| Safety Standard | IEC 61010-1 CAT IV 600V , CAT III 1000V IEC 61010-031 IEC 61010-2-032 |
| Power source | R6 (AA) (1.5V) × 2 |
| Dimensions | 250(L) × 105(W) × 49(D)mm |
| Weight | 530g approx. |
| Included Accessories | 7107A (Test leads) 8201 (Output Plug) 9094 (Carrying Case) R6 (AA) × 2 Instruction Manual |
| Optional Accessories | 8008 (Multi-Tran) (AC only) 7256 (Output cord) |