Home  //  Products  //  Clamp Meters  //  KEW 2009R  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 6201A

Jual Kyoritsu Portable Appliance Tester KEW 6201A

 

Portable Appliance Testers

KEW 6201A

KEW 6201A
CE
 
The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage.
Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.

This instrument is suitable for performing tests as required by the following standards.
AS/NZS 3760 In-service safety inspection and testing of electrical equipment.

Test Function
FunctionTests of contents
Test ⅠClass Protective conductor resistance
Insulation (250V or 500V)
Test ⅠSELECT Switch + Class Protective conductor resistance
Leakage Current test
TestⅡClass Insulation (250V or 500V)
TestⅡSELECT Switch + Class Leakage Current test
Extension Leads test Protective conductor resistance
Insulation P/N-PE
Polarity
SELECT Switch + Extension Leads test Protective conductor resistance
Leakage Current test
Leakage Current Test Leakage current measurement 

RPE 20Ω Protective Conductor Resistance Test

Measuring range  0 - 15.00Ω 
Resolution of measurement 10mΩ
Open circuit voltage < AC 12V
Measuring current 10A AC nominal value
Accuracy ±3%rdg±5dgt

RINS 200MΩ Insulation Resistance

Rating 250V/20MΩ 500V/20MΩ
Measuring range 0 - 19.99Ω
Resolution of measurement 10kΩ
Output voltage 250V DC (+20%/-10%) @1MΩ 500V DC (+20%/-10%) @1MΩ
Short circuit current 2.5mA DC or less
Accuracy ±2%rdg±3dgt

Leakage Current Test

Measuring range AC 0.1 - 19.99mA
Resolution of measurement 0.01mA
Examination time Max 15 seconds
Accuracy ±3%rdg±5dgt

AC VOLT Mains Voltage Check

Measuring range 207 - 264V
Resolution of measurement 1V
Accuracy ±2%rdg±3dgt

General

Supply voltage 240V±10%
Frequency 50Hz±1%
Applicable standards IEC 61010-1 CAT III 300V Pollution Degree2
IEC 61326-1 (EMC)
Dimensions 167(L) × 185 (W) × 89 (D) mm
Weight 1.2kg (only the instrument body)
Included Accessories 7123 (Power cord [AU])
7129A (Test leads with alligator clip)
7161A (Flat test prod [black])
7140 (Adapter for exntesion cord)
9147 (Cord case)
9121 (Shoulder strap)
Instruction manual
Optional Accessories 7121B (Distribution board test leads)

 

KEW 4140

Jual Kyoritsu  LOOP/PFC/PSC Testers KEW 4140

 

LOOP/PFC/PSC Testers

KEW 4140

KEW 4140
CE ATT
 
• Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above.
• Dual Display allows simultaneous measurements like Loop & PFC/PSC.
• Two wire connection for Loop L-L, L-N and PSC testing is possible.
• Phase rotation, Voltage and Frequency measurements.
• Lock-down test button for 'hands free' testing with auto-start operation.
• Display and front panel keyboards with Backlight to be visible in dark places.
• Water and Dust proof (IP54)
 

Loop Impedance

Function L-PE ATT OFF L-PE ATT ON L-N / L-L
Rated Voltage 230V (50/60Hz) L-N: 230V (50/60Hz)
L-L: 400V (50/60Hz)
Operating Voltage 100 - 280V (45 - 65Hz) 100 - 500V (45 - 65Hz)
Range (Auto-Ranging) 20/200/2000Ω 20/200/2000Ω
(L-N<20Ω)
20Ω
Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V 20Ω: 6A/40ms
200Ω: 2A/20ms
2000Ω: 15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx.5s
20Ω: 6A/20ms
Accuracy ±3%rdg±4dgt (*1) ±3%rdg±6dgt (*1) L-N: ±3%rdg±4dgt
L-L: ±3%rdg±8dgt

PFC (L-PE) / PSC (L-N / L-L) (*2)

Function PFC PFC (ATT) PSC
Rated Voltage 230V (50/60Hz) L-N: 230V (50/60Hz)
L-L: 400V (50/60Hz)
Operating Voltage 100 - 280V (45 - 65Hz) 100 - 500V (45 - 65Hz)
Range (Auto-Ranging) 2000A/20kA 2000A/20kA (L-N<20Ω) 2000A/20kA
Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V 20Ω: 6A/40ms
200Ω: 2A/20ms
2000Ω: 15mA/500ms
L-N: 6A/60ms
N-PE: 10mA/approx.5s
20Ω: 6A/20ms

Phase Rotation

Operating Voltage 50 - 500V, 45 - 65Hz
Remarks Correct phase sequence: displayed "1.2.3" and  mark
Reversed phase sequence: displayed "3.2.1" and  mark

Volts

Function Volts Frequency
Measuring range 0 - 500V 45 - 65Hz
Accuracy ±2%rdg±4dgt ±0.5%rdg±2dgt

 

Applicable standards IEC 61010-1 CAT III 300V (500V L to L),
IEC 61010-031, IEC 61557-1, 3, 7, 10,
IEC 60529 (IP54), IEC 61326 (EMC)
Power source 1.5V AA batteries × 6 *Use of alkaline batteries (LR6) is recommended.
Dimensions 84 (L) × 184 (W) × 133 (D) mm
Weight 860g (including batteries)
Included Accessories Main cord (*3)
Distribution board test lead (*4)
9155 (Shoulder strap)
9156 (Soft case)
LR6 (Battery) × 6, Instruction manual

 

KEW 5410

Jual RCD Testers KEW 5410

 

RCD Testers

KEW 5410

KEW 5410
CE
 
• Measurement of RCD trip time
 Conducting testing of rated residual non-operating currents at
 × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
• Measurement of trip out current
 Measuring trip out current by varying current automatically.
• Remote Test
 Enabling a user to hold the Test Leads with his both hands
 by locking the Test Button. Measurement will automatically
 start when the main voltage is detected.
• Voltage Measurement
 Carrying out a constant measurement of voltage in the
 stand-by mode at each Range.
• Auto-detection of Contact voltage
 Detecting the voltage to earth of Earth electrodes or
 Protective conductors during RCD test - when applying
 test currents - at measurement using EARTH in order to
 prevent electrical shocks caused by the damaged earth.
 Measurement will be ceased at AC50V or more.
• Dust- and Water-proof
 Dust- and Water-proof construction
 (designed to IEC 60529 IP54).
• Backlight
 Facilitating working at dimly illuminated locations.
 

Measurement of RCD trip time - Measurement of trip out current

Range× 5× 1× 1/2AUTO RAMP(mA)
Rated Voltage 100V±10%
200V-10%~+32%
400V±10%
50/60Hz
Test current 15/30/50/100mA 15/30/50/100/200/500mA 15/30/50/100/200/500mA
Measuring range Testing time
0ms~200ms
Testing time
0ms~2000ms
Testing time
0ms~2000ms
40% - 110% of lΔn
(goes up by 5%)
Testing time
300ms × 15steps
Accuracy
(Trip Time)
1%rdg±3dgt 1%rdg±3dgt 1%rdg±3dgt Test Current at each step
-4%~+4%

Accuracy
(Trip Time)

+2%~+8%dgt +2%~+8%dgt -8%~-2%dgt

Voltage Measurement

Measuring range 80V~450V 50/60Hz
Accuracy 2%rdg±4dgt
Applicable standards IEC 61010-1 Pollution degree2 CAT III 300V / CAT II 400V
IEC 61010-031
IEC 61557-1, 6
IEC 60529 (IP54)
Display 1999 counts (3 1/2digits), Large LCD
Operating temperature & humidity range 0ºC - 40ºC, relative humidity 85% (no condensation)
Storage temperature & humidity range -20ºC - 60ºC, relative humidity 85% (no condensation)
Insulation resistance 50MΩ or more / 1000V (between electrical circuit and enclosure)
Sleep Function (1)Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2) Backlight turns off in 1 minute after it lights up.
Power source DC 12V / Size AA battery R6 (SUM-3) × 8 pcs.
Dimensions 167(L)×186(W)×89(D)mm
Weight Approx. 965g (including batteries)
Possible number of Measurements 1200 times or more
(measure every 30 seconds at ×1/2 Range, lΔn=100mA)
Included Accessories 7128A (Test leads)
7129A (Test lead with alligator clip)
8017 (Long pin) × 2
Cord case, 9121 (Shoulder strap), Instruction manual,
Size AA battery R6 (SUM-3) × 8pcs.

 

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A

 

LOOP/PFC/PSC Testers

MODEL 4118A

 

MODEL 4118A
CE
 
• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 15mA LOOP measurement:
LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).
The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).
• Direct reading of Prospective Short Circuit Current (PSC).
• Safe voltage measurement function.
• Large custom digital display readout on all models.
• Measure low loop resistances(resolution of 0.01Ω)
• Automatic lock-out if test resister overheats.
• Large custom digital display readout .
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating
• Complies with IEC 61557

 

Front Cover

 

Loop Impedance Ranges 20/200/2000Ω
Loop Impedance Accuracy ±2%rdg±4dgt
AC Test Current 20Ω 25A
200Ω 2.3A
2000Ω 15mA
AC Test Period 20Ω (20ms)
200Ω (40ms)
2000Ω (280ms)
PSC Ranges 200A (2.3A 40ms)
2000A (25A 20ms)
20kA (25A 20ms)
PSC Ranges Accuracy Consider accuracy of Loop impedance
Voltage 110V-260V ±2%rdg±4dgt
Operating Voltage 230V+10% -15% (195V - 253V) 50Hz
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61557-1,-3
IEC 61010-2-031
IP Rating IEC 60529-IP54
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 750g approx.
Accessories Molded plug test leads
7121B (Simplified measurement probe)
Pouch for test leads
9121 (Shoulder Strap)
Instruction Manual

 

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A

 

RCD Testers

MODEL 5406A

MODEL 5406A
CE
 
• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 0 and 180 degree phase angle switch permits quick tests and consistent readings.
• Digital read-out of tripping time.
• Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
• Large custom digital display readout.
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating.
• Complies with IEC 61557
• Test of a large kind of RCD's: Standard, Selective, AC and A (DC sensitive breakers)
 
Rated Tripping Current 10/20/30/200/300/500mA
Fault Condition Settings × 1/2, × 1, × 5, × DC,
AUTO RAMP
Trip Current Duration 1000ms, 200ms (×5)
Lowest Resolution 1ms
Trip Time Accuracy ±0.6%rdg±4dgt
Operating Voltage 230V+10%-15%
(195V - 253V) 50Hz
Safety Standard IEC 61557-1,-6
IEC 61010-1 CAT III 300V
IEC 61010-2-031 Pollution Degree 2
Withstand Voltage 3700V AC for 1 minute
IP Rating IEC 60529-IP54
Dimensions 167(L) × 186(W) × 89(D)mm
Weight 800g approx.
Accessories Molded plug test leads
Pouch for test leads
9121 (Shoulder Strap)
Instruction Manual
Optional 7121B (Simplified measurement probe)

 

206853
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
148
84
822
205067
2463
5007
206853

Your IP: 18.210.22.132