Home  //  Products  //  Clamp Meters  //  KEW 2046R  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 3021

Jual Digital Insulation / Continuity Testers KEW 3021

 

Digital Insulation / Continuity Testers

KEW 3021

KEW 3021
CE
AutoDischarge
 
• 3 functions in one unit, insulation test with 4 voltage ranges,
 continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
 on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
  • 125V 250V 500V 1000V DCACV Resistance Continuitybuzzer Backlight AutoPowerOff
 

Insulation resistance

Test voltage 125/250/500/1000V
Measuring range
(Auto range)
4.000/40.00/200.0MΩ(125V)
4.000/40.00/400.0/2000MΩ(250/500/1000V)
First effective measuring range 0.1 - 20MΩ (125V)
0.1 - 40MΩ (250V)
0.1 - 200MΩ (500V)
0.1 - 1000MΩ (1000V)
Mid-scale value 5MΩ (125/250V)
50MΩ (500V/1000V)
Accuracy ±2%rdg±6dgt
Second effective measuring range lower 0 - 0.099MΩ
Second effective measuring range upper 20.01 - 200.0MΩ (125V)
40.01 - 2000MΩ (250V)
200.1 - 2000MΩ (500V)
1001 - 2000MΩ (1000V)
Accuracy ±5%rdg±6dgt
Rated current DC 1 - 1.2mA
Output short circuit current 1.5mA max

Ω/Continuity

Auto range 40.00/400.0Ω
Accuracy ±2%rdg±8dgt
Output voltage on open circuit 5V±20%
Output short circuit current DC 220±20mA
Fuse Quick acting ceramic fuse 0.5A/600V (Ø6.35×32mm)

AC Voltage

AC voltage range AC 20 - 600V (50/60Hz)
DC -20 - -600V/+20 - +600V
Accuracy ±3%rdg±6dgt

General

Applicable standards IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC),
IEC 60529 (IP40)
Power source R6 × 6 or LR6 × 6
Dimensions / Weight 105(L) × 158(W) × 70(D)mm / 600g approx.
Included Accessories 7150A (Remote control switch set),
9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual
Optional Accessories 7115 (Extension Probe), 8016 (Hook type prod),
8923 (Fuse [0.5A/600V]), 9089 (Carrying Case)

 

MODEL 3007A

Jual Digital Insulation / Continuity Testers MODEL 3007A

 

Digital Insulation / Continuity Testers

MODEL 3007A

MODEL 3007A
CE
AutoDischarge
 
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Trac-Lok mode to conserve battery life on insulation and continuity tests.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• Backlight function to view the test results in dimly lit areas.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
  • ACV Resistance Continuitybuzzer Backlight AutoPowerOff 250V 500V 1000V
 

Insulation Resistance

Test voltage 250V/500V/1000V
Measuring ranges
(Mid-scale value)
20MΩ/200MΩ/2000MΩ
Output voltage on open circuit Rated test voltage+20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1.5 mA DC approx.
Accuracy ±1.5%rdg±5dgt (20MΩ/200MΩ)
±10%rdg±3dgt (2000MΩ)

Continuity Test

Measuring ranges
(Mid-scale value)
20Ω/200Ω/2000Ω
Output voltage on open circuit 7 - 12V DC
Measuring current 200mA DC min.
Accuracy ±1.5%rdg±5dgt (20Ω)
±1.5%rdg±3dgt (200Ω/2000Ω)

AC Voltage

AC voltage range 0-600V AC
Accuracy ±5%rdg±3dgt

General

Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Power source R6 (AA) (1.5V) × 8
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 990g approx
Included Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 8
Shoulder Strap
Instruction Manual

 

MODEL 3132A

Jual Analogue Insulation / Continuity Testers MODEL 3132A

 

Analogue Insulation / Continuity Testers

MODEL 3132A

MODEL 3132A
CE
Analogue Insulation / Continuity Tester
•Dust and drip proof construction. (designed to IEC 60529 IP54)
•Designed to meet IEC 61010-1 and IEC 61557 safety standard.
•1mA rated test current at the minimum resistance.
•200mA measuring current on continuity testing.
•Automatic discharge of circuit capacitance.
(Any charge stored in the circuit under test will be automatically discharged after testing.)
•Live circuit warning buzzer and neon lamp.
•Small and lightweight. Shock resistant new case material.
•AC voltmeter with linear, easy-to-read scale.
•Operates on AA, R6 × 6 dry batteries.
  • ACV Resistance 250V 500V 1000V
 

Insulation Resistance

Test voltage 250V/500V/1000V
Measuring ranges
(Mid-scale value)
100MΩ/200MΩ/400MΩ
(1MΩ) (2MΩ) (4MΩ)
Output voltage on open circuit Rated test voltage+20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1 - 2mA DC
Accuracy 0.1 - 10MΩ/0.2 - 20MΩ/0.4 - 40MΩ
(Accuracy Guaranteed Ranges) ±5% of indicated value

Continuity

Measuring ranges
(Mid-scale value)
3Ω/500Ω
(1.5Ω) / (20Ω)
Output voltage on open circuit 4.1V DC approx.
Measuring current 210mA DC min.
Accuracy ±1.5% of scale length

AC Voltage

AC Voltage 0 - 600V AC
Accuracy ±5% of scale length

General

Safety Standard IEC 61010-1 CAT III 600V Pollution Degree 2
IEC 61010-2-031
IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Power source R6 (AA) (1.5V) × 6
Dimensions 106(L) × 160(W) × 72(D)mm
Weight 560g approx.
Included Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 6
9121 (Shoulder Strap)
Instruction Manual

 

MODEL 3005A

Jual Digital Insulation / Continuity Testers MODEL 3005A

 

Digital Insulation / Continuity Testers

MODEL 3005A

MODEL 3005A
CE
AutoDischarge
 
• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.
  • ACV Resistance Continuitybuzzer AutoPowerOff 250V 500V 1000V
 

Insulation Resistance

Test voltage 250V/500V/1000V
Measuring ranges
(Mid-scale value)
20MΩ/200MΩ/2000MΩ
Output voltage on open circuit Rated test voltage+20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1.5 mA DC approx.
Accuracy ±1.5%rdg±5dgt (20MΩ/200MΩ)
±10%rdg±3dgt (2000MΩ)

Continuity Test

Measuring ranges
(Mid-scale value)
20Ω/200Ω/2000Ω
Output voltage on open circuit 7 - 12V DC
Measuring current 200mA DC min.
Accuracy ±1.5%rdg±5dgt (20Ω)
±1.5%rdg±3dgt (200Ω/2000Ω)

AC Voltage

AC voltage range 0 - 600V AC
Accuracy ±5%rdg±3dgt

General

Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Power source R6 (AA) (1.5V) × 8
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 970g approx
Included Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 8, Shoulder Strap
Instruction Manual

 

MODEL 3131A

Jual Analogue Insulation / Continuity Testers MODEL 3131A

 

Analogue Insulation / Continuity Testers

MODEL 3131A

MODEL 3131A
CE
 
The Model 3131A offers unmatched performance, and feature including test lead resistance zero adjustment for time-saving continuous operation, a clear ease to read illuminated scale, and a live circuit warning.

• Test insulation up to 100MΩ at 250V, 200MΩ at 500V, 400MΩ at 1000V and continuity up to 20Ω.
• LIVE circuit warning lamp plus audible warning.
• Automatic discharge of circuit capacitance when TEST button is released.
• Fuse protected (continuity range only).
• Battery check LED.
• Front panel zero adjust.
• Back light function to facilitate working at dimly lit situations.
• PRESS TO TEST button with lock down feature.
  • Resistance Backlight 250V 500V 1000V
 

Insulation Resistance

Test voltage 250V/500V/1000V
Measuring ranges
(Mid-scale value)
100MΩ/200MΩ/400MΩ
(1MΩ) / (2MΩ) / (4MΩ)
Output voltage on open circuit Rated test voltage+20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1.3 mA DC approx.
Accuracy 0.1 - 10MΩ/0.2 - 20MΩ/0.4 - 40MΩ
(Accuracy Guaranteed Ranges) ±5% of indicated value

Continuity

Measuring ranges
(Mid-scale value)
2Ω/20Ω
(1Ω)/(10Ω)
Output voltage on open circuit 4 - 9V DC
Measuring current 200mA DC min
Accuracy ±3% of scale length

General

Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61557-1/2/4
IP Rating IEC 60529-IP54
EMC Standard IEC 61326-1
Power source R6 (AA) (1.5V) × 6
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 860g approx.
Included Accessories 7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 6
9121 (Shoulder Strap)
Instruction Manual

 