Home  //  Products  //  Clamp Meters  //  KEW 2055  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

MODEL 2433R

Leakage Clamp Meters

MODEL 2433R

 

MODEL 2433R
CE
 
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.

TRUE RMS φ40 MAX400A ACA DATAHOLD PeakHold10ms Filter AutoPowerOff

 

 

AC A (50/60Hz) 40/400mA/400A
±1%rdg±5dgt (40/400mA)
±1%rdg±5dgt (0 - 300A)
±2%rdg (300.1 - 399.9A)
AC A (WIDE) 40/400mA/400A
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [20Hz - 1kHz] (40/400mA)
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [40Hz - 1kHz] (0 - 300A)
±2%rdg [50/60Hz],
±5%rdg [40Hz - 1kHz] (300.1 - 399.9A)
Maximum circuit voltage 600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size Ø40mm max.
Frequency response 20Hz - 1kHz [40Hz - 1kHz:400A]
Effect of External Stray Magnetic Field 10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Applicable standards IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response Time Approx. 2 seconds
Power source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 270g approx.
Included Accessories 9052 (Carrying Case) R03 (1.5V) × 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*

 

MODEL 2433

Leakage Clamp Meters

MODEL 2433

 

MODEL 2433
CE
 
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.

φ40 MAX400A Filter PeakHold10ms

 

 

AC A (50/60Hz) 40/400mA/400A
±1%rdg±5dgt (40/400mA)
±1%rdg±5dgt (0 - 350A)
±2%rdg (350.1 - 399.9A)
AC A (WIDE) 40/400mA/400A
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [20Hz - 1kHz] (40/400mA)
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [40Hz - 1kHz] (0 - 350A)
±2%rdg [50/60Hz],
±5%rdg [40Hz - 1kHz] (350.1 - 399.9A)
Maximum circuit voltage 600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size Ø40mm max.
Frequency response 20Hz - 1kHz (40Hz - 1kHz:400A)
Effect of External Stray Magnetic Field 10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response Time Approx. 2 seconds
Power source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 270g approx.
Included Accessories 9097 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*

 

MODEL 2431

Leakage Clamp Meters

MODEL 2431

 

MODEL 2431
CE
 
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges 20mA/200mA/200A.
• Rotary switch for easy one finger power-on and range selection.
• Resolution 0.01mA.

φ24 MAX200A Filter

 

 

AC A (50/60Hz) 20/200mA/200A
±3%rdg±5dgt (20/200mA/100A)
±5%rdg±5dgt (200A)
AC A (WIDE) 20/200mA/200A
±2%rdg±4dgt [50/60Hz] (20/200mA/0 - 100A)
±5%rdg±6dgt [40 - 400Hz] (20/200mA/0 - 100A)
±5%rdg±4dgt [50/60Hz] (100.1 - 200A)
Conductor size Ø24mm max.
Frequency response 40 - 400Hz
Effect of external stray magnetic field φ15mm 100A 10mA AC max.
Safety Standard IEC 61010-1 CAT III 300V
IEC 61010-2-032
Power source LR-44 (1.5V)× 2
Dimensions 149(L)× 60(W) × 26(D)mm
Weight 120g approx.
Included Accessories 9090 (Carrying Case)
LR-44 × 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*

 

MODEL 2432

Leakage Clamp Meters

MODEL 2432

 

MODEL 2432
CE
 
• High Sensitive Model
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA.

φ40 MAX100A Filter PeakHold10ms

 

 

AC A (50/60Hz) 4/40mA/100A
±1%rdg±5dgt (4/40mA)
±1%rdg±5dgt (0 - 80A)
±5%rdg (80.1 - 100A)
AC A (WIDE) 4/40mA/100A
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [20Hz - 1kHz] (4/40mA)
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [40Hz - 1kHz] (0 - 80A)
±5%rdg [50/60Hz],
±10%rdg [40Hz - 1kHz] (80.1 - 100A)
Maximum circuit voltage 600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size Ø40mm max.
Frequency response 20Hz - 1kHz (40Hz - 1kHz:100A)
Effect of External Stray Magnetic Field 2mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response Time Approx. 2 seconds
Power source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 290g approx.
Included Accessories 9097 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*

 

KEW 2413R

Leakage Clamp Meters

KEW 2413R

 

KEW 2413R
CE
 
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables an accurate measurement for distorted waveforms.
• Measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2 way analogue output terminal
• Resolution 0.1mA

TRUE RMS φ68 MAX1000A ACA DATAHOLD PeakHold10/100ms OutPut Filter Backlight

 

 

AC A (50/60Hz) 200mA/2/20/200/1000A
±2.5%rdg±5dgt (200mA/2/20A)
±3.0%rdg±5dgt (200A, 0 - 500A)
±5.5%rdg (501 - 1000A)
AC A (WIDE) 200mA/2/20/200/1000A
±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A)
±2.0%rdg±5dgt (50/60Hz) (200A, 0 - 500A)
±5.0%rdg (50/60Hz) (501 - 1000A)
Crest factor 3.0 or less
Conductor size Ø68mm max.
Frequency response 40Hz - 1kHz
Output Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-2-032
Power source 6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours
Dimensions 250(L) × 130(W) × 50(D)mm
Weight Approx. 570g (including battery)
Included Accessories 9094 (Carrying Case)
6F22 × 1
Instruction Manual
Optional Accessories 7073 (2WAY Output Cord)