Home  //  Products  //  Clamp Meters  //  KEW 2413F  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 5010

Jual Loggers KEW 5010

 

Loggers

KEW 5010

KEW 5010
CE
3 channel inputs for the simultaneous recording of Leakage Current and Load Current
• Large capacity for storing 60,000 data points
• Lowpass Filter will filter out the harmonics
• LED flickers when the preset current value is exceeded
• CALL:Confirmation of recorded data
• Selection of One-time mode or Endless mode
• Non Volatile Memory
• Battery power indicator
• The userfriendly PC software "KEW LOG Soft 2" is supplied
• Continuous measuring time:Approx. 10 days (Alkaline Battery)
  • TRUE RMS USB External

  • 3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
  • Large Capacity for storing 60,000 data points
    • 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded
  • Lowpass Filter will filter out the harmonics (Cutoff Frequency = Approx. 160Hz)
  • LED flickers when the preset current value is exceeded
  • CALL: Confirmation of recorded data
    • The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)
    • RECALL: The last 10 recorded data points including time/date can be recalled on the logger display
  • Selection of One-time mode or Endless mode
    • One-time on: Recording will stop when memory is used up
    • One-time off: Overwrite the old data, and store the latest data
  • Non Volatile Memory
    Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)
  • Battery power indicator
    Indicates battery voltage in 4-levels
    (It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)
  • The userfriendly PC software "KEW LOG Soft 2" is supplied
    • Supplied with the user friendly software "KEW LOG Soft 2". This permits editing, analysis and graphical display of data.
    • The recorded data is downloadable onto a PC via USB cable.
  • Continuous measuring time: Approx. 10 days (Alkaline Battery)

Normal Recording Mode
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)

RangeRMS Accuracy
100.0mA ±2.0%rdg±0.9%f.s.+ Accuracy of Sensor
Other ranges ±1.5%rdg±0.7%f.s.+ Accuracy of Sensor
Crest Factor 2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.

*Max, Min and Instant Peak values in Normal Recording mode are just reference values:
their accuracies aren't guaranteed.

Trigger Recording Mode (AC 50/60Hz sine wave)

RangeAccuracy
100.0mA ±3.5%rdg±2.2%f.s.+ Accuracy of Sensor
Other ranges ±3.0%rdg±2.0%f.s.+ Accuracy of Sensor

Capture Recording Mode

RangeAccuracy
100.0mA ±3.0%rdg±1.7%f.s.+ Accuracy of Sensor
Other ranges ±2.5%rdg±1.5%f.s.+ Accuracy of Sensor
Recording mode Normal, Trigger, Capture
Operating system Successive Approximation
(CH1 single synchronized sampling)
Rated max. working voltage AC 9.9Vrms, 14V peak value
Number of input channel 3ch
Measuring method True RMS
RMS measuring interval approx. 100ms
Sampling interval Normal/Trigger mode : approx. 1.65ms/CH
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)
Low battery warning Battery mark display (in 4 levels)
Over-range indication "OL" mark is displayed when exceeding the measuring range
Auto power off Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)
Possible measurement time Approx. 10 days (with alkaline LR6 batteries)
Applicable standards IEC 61010-1:2001 CAT III 300V Pollution degree2
IEC 61326 (EMC standard)
Dimensions 111(L)×60(W)×42(D)mm
Weight Approx. 265g
Included Accessories Alkaline battery LR6×4pcs, 9118 (Carrying case)
PC software "KEW LOG Soft 2", 7148 (USB cable)
Instruction manual, Quick manual, Install manual,
USB Notice sheet
Optional Accessories 8146/8147/8148 (Leakage & Load current Clamp Sensor),
8121/8122/8123 (Load current Clamp Sensor),
8129/8130 (Flexible Clamp Sensor),
8320 (AC Adapter),
9135 (Carrying bag), 9119 (Hard carry case),
7185 (Extension cable for sensor)

 

Loggers/PQA

Jual Loggers/PQA

Loggers/PQA

Loggers

  • KEW 5010

    KEW 5010

    3 channel inputs for the simultaneous recording of Leakage Current and Load Current
    • Large capacity for storing 60,000 data points
    • Lowpass Filter will filter out the harmonics
    • LED flickers when the preset current value is exceeded
    • CALL:Confirmation of recorded data
    • Selection of One-time mode or Endless mode
    • Non Volatile Memory
    • Battery power indicator
    • The userfriendly PC software "KEW LOG Soft 2" is supplied
    • Continuous measuring time:Approx. 10 days (Alkaline Battery)

    • TRUE RMS USB External
    • KEW 5020

      KEW 5020

      3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
      • Power Quality analysis
      • Large capacity for storing 60,000 data points
      • Lowpass Filter will filter out the harmonics
      • LED flickers when the preset current/voltage value is exceeded
      • CALL:Confirmation of recorded data
      • Selection of One-time mode or Endless mode
      • Non Volatile Memory
      • Battery power indicator
      • The userfriendly PC software "KEW LOG Soft 2" is supplied
      • Continuous measuring time:Approx. 10 days (Alkaline Battery)

      • TRUE RMS USB External

 

Power Meter

  • KEW 6305

    KEW 6305

    • Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
    • Voltage, Current, Power Factor and Frequency measurements
    • Power analysis (Active, Apparent and Reactive power)
    • Energy analysis (Active, Apparent and Reactive power)
    • Active power accuracy: ±0.3%rdg±0.2%f.s.
    • Automatic wiring check function to prevent incorrect connections
    • Large memory capability (2GB) using built-in SD card interface
    • Real time & remote measurements using Android application
    • synchronous measurements between two units of KEW 6305
    • Wide selection of clamp sensors allow measurements from 0.1A to 3000A
    • The instrument automatically recognizes what kind of clamp sensor is connected to it
    • Windows software for data analysis and setting via USB port or Bluetooth

    • TRUE RMS USB Bluetooth External

 

Power Quality Analyzer

KEW 6315

KEW 6315NEW

• Simultaneous Power & Power quality measurements
• Helpful support functions
• Measurement with high accuracy
• Remote monitoring on PC and Android device
• Various Clamp Current Sensors
• Energy consumption check on site
• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V

  • TRUE RMS USB Bluetooth External

 

MODEL 4200

Jual Earth Clamp Testers MODEL 4200

 

Earth Clamp Testers

MODEL 4200

MODEL 4200
CE
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display "NOISE" mark on the LCD.
• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2

Note:
A single earthing can not be measured. (Only for Multiple Earthing System)
  • TRUE RMS φ32 Backlight

Earth resistance Auto range 20.00/200.0/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)*
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)
AC current (50Hz/60Hz) Auto range Values are displayed, but accuracy isn't guaranted(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)
Operating indication Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication "OL"is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)
Sample rate Approx. 1 times per second
Current consumption Approx. 50mA (max.100mA)
Measurement time Approx.12 hours (when R6 is used)
Approx.24 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.
Conductor size Approx. Ø32mm
Applicable standards IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions 246(L)×120(W)×54(D)mm
Weight Approx. 780g (including batteries)
Included Accessories R6 x 4, Instruction manual
8304 (Resister for operation check)
9166 (Carrying case[Hard])

KEW 4202

Jual Earth Clamp Testers KEW 4202

 

Earth Clamp Testers

KEW 4202

KEW 4202
CE
Various useful functions are available on Android devices using Bluetooth communication
• Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)
• Saved data includes measurement, GPS location and date & time Easy to check on map "When" and "Where" the measurement was made
• Comparator function on Android device informs when the measured value is lower/higher than the preset value

Earth /Ground resistance and Leakage current measurement functions
• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems
• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks
• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments
  • TRUE RMS φ32 Backlight Bluetooth

Free Android software "KEW smart 4202"
is available on "Google Play Store"(*)

<System requirement>
• Supporting Android ver. 2.2 - 4.4
• WVGA (800 × 480) resolution or higher
• GPS function

(*)Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.

Earth resistance Auto range 20.00/200.00/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)
AC current (50Hz/60Hz) Auto range Values are displayed, but accuracy isn't guaranted(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)
Operating indication Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication "OL"is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)
Sample rate Approx. 1 times per second
Communication Interface Bluetooth Ver2.1 + EDR Class2
Current consumption Approx. 50mA (max.100mA)
Measurement time Approx.5 hours (when R6 is used) Approx. 21 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.
Conductor size Approx.Ø32mm
Applicable standards IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions 246(L)×120(W)×54(D)mm
Weight Approx. 780g (including batteries)
Included Accessories LR6 x 4, Instruction manual
8304 (Resister for operation check)
9167 (Carrying case[Hard])

KEW 4106

Jual Earth Resistance & Resistivity Tester KEW 4106

 

Earth Resistance & Resistivity Tester

KEW 4106

KEW 4106
CE
Earth Resistance & Resistivity Tester
• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
  • Backlight
 
FunctionRangeResolutionMeasuring rangeAccuracy
Earth resistance
Re
(Rg at
ρ measurement)
0.001Ω 0.03 - 2.099Ω ±2%rdg±0.03Ω
20Ω 0.01Ω 0.03 - 20.99Ω ±2%rdg±5dgt (*1)
200Ω 0.1Ω 0.3 - 209.9Ω
2000Ω 3 - 2099Ω
20kΩ 10Ω 0.03k - 20.99kΩ
200kΩ 100Ω 0.3k - 209.9kΩ
Auxiliary earth resistance
Rh, Rs
      8% of Re+Rh+Rs
Earth resistivity
ρ
0.1Ω·mm - 1Ω·m
Autoranging
0.2 - 395.6Ω·m ρ=2×π×a×Rg (*2)
20Ω 0.2 - 3956Ω·m
200Ω 20 - 39.56kΩ·m
2000Ω 0.2 - 395.6kΩ·m
20kΩ 2.0 - 1999kΩ·m
200kΩ
Series interference voltage
Ust (A.C only) (*3)
50V 0.1V 0 - 50.9Vrms ±2%rdg±2dgt (50/60Hz)
±3%rdg±2dgt (40 - 500Hz)
Frequency
Fst
Autoranging 0.1Hz
1Hz
40Hz - 500Hz ±1%rdg±2dgt
Measuring method Earth resistance: Fall-of-potential method
(currents and voltages measured via the Probes)
Measurement method of Earth Resistivity (ρ): Wenner 4-pole method
Series interference voltage (earth voltage)
RMS Rectifier (between the E-S Terminals)
Memory capacity 800 data
Communication Interface Model 8212-USB Optical Adaptor
LCD Dot-matrix 192×64 monochrome
Over-range Indication "OL"
Overload Protection between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Applicable standards IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
Power source DC12V : sizeAA manganese dry battery (R6) × 8
(Auto power off: approx. 5 minutes)
Dimensions 167(L) × 185(W) × 89(D) mm
Weight approx. 900g (including batteries)
Accessories 7229A (Earth precision measurement),
7238A (Simplified measurement test leads),
8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),
8200-04 (Cord reel [4 pcs])×1 set,
8212-USB (USB adaptor with "KEW Report(Software)"),
9121 (Shoulder strap),
9125 (Carrying case),
R6 × 8, Instruction manual, Calibration certificate
Optional 8212-RS232C (RS232C adaptor with "KEW Report(Software)")

 

206247
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
101
115
216
205067
1857
5007
206247

Your IP: 3.227.249.234
Server Time: 2019-10-14 19:21:03