Home  //  Products  //  Clamp Meters  //  KEW 2413F  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 2413F

Leakage Clamp Meters

KEW 2413F

 

KEW 2413F
CE
 
• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal.
• Resolution 0.1mA.

φ68 MAX1000A ACA DATAHOLD PeakHold10/100ms OutPut Filter

 

 

AC A (50/60Hz) 200mA/2/20/200A/1000A
±1.5%rdg±2dgt (200mA/2/20A)
±2%rdg±2dgt (200A 0 - 500A)
±5.5%rdg (501 - 1000A)
AC A (WIDE) 200mA/2/20/200/1000A
±1%rdg±2dgt [50/60Hz],
±3%rdg±2dgt [40Hz - 1kHz] (200mA/2/20A)
±1.5%rdg±2dgt [50/60Hz],
±3.5%rdg±2dgt [40Hz - 1kHz] (200A/0 - 500A)
±5%rdg [50/60Hz],
±10%rdg [40Hz - 1kHz] (501 - 1000A)
Conductor size Ø68mm max.
Frequency response 40Hz - 1kHz
Effect of external stray magnetic field φ15mm 100A 10mA AC max.
Output Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Applicable standards IEC 61010-1 CAT III 300V
IEC 61010-2-032
Power source 6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours
Dimensions 250(L) × 130(W) × 50(D)mm
Weight 570g approx.
Included Accessories 9094 (Carrying Case)
6F22 × 1
Instruction Manual
Optional Accessories 7073 (2WAY Output Cord)

 

MODEL 2412

Leakage Clamp Meters

MODEL 2412

 

MODEL 2412
 
• Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring.
• Resolution 0.01mA.

φ40 MAX500A ACV Resistance OutPut Filter External

 

 

AC A (50/60Hz) 20/200mA/2/20/200/500A
±1.5%rdg±5dgt (20/200mA/2A)
±2%rdg±5dgt (20/200A)
±2.5%rdg±5dgt (500A)
AC A (WIDE) 20/200mA/2/20/200/500A
±1%rdg±3dgt [50/60Hz],
±5%rdg±5dgt [40 - 400Hz] (20/200mA/2A)
±1.5%rdg±3dgt [50/60Hz],
±5%rdg±5dgt [40 - 400Hz] (20/200A)
±2%rdg±3dgt [50/60Hz],
±5%rdg±5dgt [40 - 400Hz] (500A)
AC V 600V
±2%rdg±5dgt (50/60Hz)
±5%rdg±5dgt (40 - 400Hz)
Ω 200Ω ±1.5%rdg±5dgt
Conductor size Ø40mm max.
Frequency response 40 - 400Hz
Effect of external stray magnetic field φ15mm 100A 10mA AC max.
Output Recorder : DC200mV against the maximum value of each range (500A range is 50mV)
Power source 6F22 (9V) × 1 or AC Adaptor
Dimensions 209(L) × 96(W) × 45(D)mm
Weight 450g approx.
Included Accessories 7066A (Test leads)
9169 (Carrying case)
8025 (Plug for output jack)
6F22 × 1
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*
8022 (AC adaptor) (110V)
8023 (AC adaptor) (220V)
7256 (Output cord)

 

KEW 2056R

AC/DC Digital Clamp Meters

KEW 2056R

 

KEW 2056R
CE
 
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.
• True RMS enables an accurate measurement.

TRUE RMS CAT4 600V φ40 MAX1000A DCACV DCACA Resistance Continuitybuzzer FrequencyDUTY Diode Capacitance Temperature Backlight DATAHOLD PeakHold10ms MAX/MIN RelativeAutoPowerSave AutoPowerOff

 

 

AC A 0 - 600.0/1000A
±2.0%rdg±5dgt (50/60Hz)
±3.5%rdg±5dgt (40 - 500Hz)
DC A 0 - 600.0/1000A
±1.5%rdg±5dgt
AC V 6/60/600V
Auto Ranging
±1.5%rdg±4dgt (50/60Hz)
±3.5%rdg±5dgt (40 - 400Hz)
DC V 600m/6/60/600V
Auto Ranging
±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt (600 - 6M) / ±5%rdg±8dgt (60M)
Continuity buzzer Buzzer Sounds at 100Ω
Temperature -50ºC - +300ºC (With the use of Temperature probe 8216)
Frequency/DUTY 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9%
Conductor size Ø40mm
Safety Standard IEC 61010-1 CAT IV 600V,
IEC 61010-031,
IEC 61010-2-032,
IEC 61326
Power source R03 (1.5V) (AAA) × 2
Dimensions 254(L) × 82(W) × 36(D)mm
Weight 310g
Included Accessories 7066A (Test leads)
9094 (Carrying case)
Instruction Manual
Optional Accessories 8008 (Multi-Tran)
8216 (Temperature probe)

 

MODEL 2300R

Fork Current Tester

MODEL 2300R

 

MODEL 2300R
CE
 
• True RMS reading is an essential feature for accurate measurement.
• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
• Set the DC current range to zero in one touch with the Zero Adjust function.

TRUE RMS φ10 MAX100A DCACA DATAHOLD AutoPowerOff

KEW FORK 2300R can be used in crowded connection boxes, where cables are very short, and space is too limited to clamp cables using with a traditional clamp meter.

 

True RMS (Root Mean Square) Value Measurement

When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc...,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
 The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.

(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)

 

Current measurement AC A 0 to 100.0A ±2.0%rdg±5dgt (50/60Hz)
DC A 0 to ±100.0A ±2.0%rdg±5dgt
Crest factor 2.5
Non contact voltage Detect AC voltage without contacting with socket wire
During voltage detection, "Hi" flashes and a buzzer sounds
Maximum digit 1,049
Conductor size Max Ø10mm
Safety Standard IEC 61010-1 CAT III 300V Pollution degree 2
Power source R03 (AAA) × 2 (Auto power off: approx.10 minutes)
*Continuous measuring time: AC A approx. 46 hours DC A approx. 52 hours
Dimensions 161.3(L) × 40.2(W) × 30.3(D)mm
Weight 110g (with batteries)
Included Accessories 9113 (Carrying Case)
R03 (AAA) × 2
Instruction Manual

 

KEW 2055

AC/DC Digital Clamp Meters

KEW 2055

 

KEW 2055
CE
 
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Very useful for power distribution companies, power utilities and maintenance fields.

CAT4 600V φ40 MAX1000A DCACV DCACA Resistance Continuitybuzzer Frequency DUTYDiode Backlight DATAHOLD MAX/MIN Relative AutoPowerSave

 

 

 

AC A 0 - 600.0/1000A
±1.5%rdg±5dgt (50/60Hz)
±3.0%rdg±5dgt (40 - 400Hz)
DC A 0 - 600.0/1000A
±1.5%rdg±5dgt
AC V 6/60/600V
Auto Ranging
±1.3%rdg±4dgt (50/60Hz)
±3.0%rdg±5dgt (40 - 400Hz)
DC V 600m/6/60/600V
Auto Ranging
±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt (600 - 6M) / ±5%rdg±8dgt (60M)
Continuity buzzer Buzzer Sounds at 100Ω
Frequency/DUTY 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9%
Conductor size Ø40mm
Safety Standard IEC 61010-1 CAT IV 600V,
IEC 61010-031,
IEC 61010-2-032,
IEC 61326
Power source R03 (1.5V) (AAA) × 2
Dimensions 254(L) × 82(W) × 36(D)mm
Weight 310g
Included Accessories 7066A (Test leads)
9094 (Carrying case)
Instruction Manual
Optional Accessories 8008 (Multi-Tran)