Home  //  Products  //  Clamp Meters  //  MODEL 2300R  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 1012

Kyoritsu Indonesia - Jual Digital Multimeters KEW 1012

KEW 1012

 

KEW 1012
CE
 
• True RMS can measure and indicate distorted waveforms
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation

TRUE RMS DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Temperature DATAHOLD MAX/MIN Relative AutoPowerOff

 

 

 

DC V 600.0mV/6.000/60.00/600.0/600V
(Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V)
AC V 6.000/60.00/600.0/600V
(Input Impedance: 10MΩ) ±1.5%±5dgt
(6.000V) ±1.2%±3dgt (60.00/600.0V) ±1.5%±5dgt (600V)
DC A 600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A)
AC A 600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A)
Ω 600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt
(600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ)
Continuity buzzer 0 - 600Ω (Buzzer sounds below 100Ω)
Diode test 2.8V Release Voltage:Approx. 0.4mA Test Current
Capacitance 40/400nF/4/40/400/4000µF
Frequency 10/100/1000Hz/10/100/1000kHz/10MHz
DUTY 0.1 - 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz)
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-1 CAT II 600V Pollution degree 2
IEC 61010-031
IEC 61326
Display 6040 Counts
Power source R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes)
Dimensions 161(L) × 82(W) × 50(D)mm
Weight Approx. 280g
Included Accessories 7066A (Test leads)
0.8A/600V (Ceramic Fuse) × 1built-in
10A/600V (Ceramic Fuse) × 1built-in
R6 × 2
Instruction Manual
Optional Accessories 7234 (Crocodile clip test lead)
9095 (Carrying case)

 

KEW 1011

Kyoritsu Indonesia - Jual Digital Multimeters KEW 1011

KEW 1011

 

KEW 1011
CE
 
• Temperature measurement, selectable for ºC and ºF
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation

DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Temperature DATAHOLD MAX/MIN Relative AutoPowerOff

 

 

 

DC V 600.0mV/6.000/60.00/600.0/600V
(Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V)
AC V 6.000/60.00/600.0/600V
(Input Impedance: 10MΩ) ±1.0%±3dgt
(6.000/60.00/600.0V)±1.5%±3dgt (600V)
DC A 600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A)
AC A 600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A)
Ω 600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt
(600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ)
Continuity buzzer 0 - 600Ω (Buzzer sounds below 100Ω)
Diode test 2.8V Release Voltage:Approx. 0.4mA Test Current
Capacitance 40/400nF/4/40/400/4000µF
Frequency 10/100/1000Hz/10/100/1000kHz/10MHz
DUTY 0.1 - 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz)
Temperature -50 - 300ºC (-58 - 572ºF)
(with the use of Temperature probe 8216)
Note: KEW 1011 can measure max. 700ºC
In order to measure over 300ºC, please use a K-type temperature probe available in the market.
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-1 CAT II 600V Pollution degree 2
IEC 61010-031
IEC 61326
Display 6040 Counts
Power source R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes)
Dimensions 161(L) × 82(W) × 50(D)mm
Weight Approx. 280g
Included Accessories 7066A (Test leads)
8216 (K-type Temperature probe)
0.8A/600V (Ceramic Fuse) × 1built-in
10A/600V (Ceramic Fuse) × 1built-in
R6 × 2Instruction Manual
Optional Accessories 7234 (Crocodile clip test lead)
9095 (Carrying case)

 

KEW 1021R

Kyoritsu Indonesia - Jual Digital Multimeters KEW 1021R

KEW 1021R

NEW

 

KEW 1021R
CE
 
• Elegant and easy-to-use cabinet
• Large display with 6000 counts and Backlight
• Enhanced current measuring function using an external clamp sensor
• Two detachable holders, flat and wing type
• Accurate reading with True RMS
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V

TRUE RMS CAT4 300V CAT3 600V DCACV DCACA Resistance Continuitybuzzer Diode CapacitanceFrequency DUTY Backlight DATAHOLD Relative MAX/MIN AutoPowerSave

 

 
DC V 6.000/60.00/600.0V (auto range)
±0.5%rdg ±3dgt
DC mV 600.0mV
±1.5%rdg ±3dgt
DC Clamp Sensor 60.00/200.0A (auto range)
±1.5%rdg ±3dgt + Sensor accuracy
AC V 6.000/60.00/600.0V (auto range)
±1.0%rdg ±3dgt [40 - 500Hz]
AC mV 600.0mV
±2.0%rdg ±3dgt [40 - 500Hz]
AC Clamp Sensor 60.00/200.0A (auto range)
±2.0%rdg ±3dgt + Sensor accuracy [40 - 500Hz]
DC A 6.000/10.00A (auto range)
±1.5%rdg ±3dgt
AC A 6.000/10.00A (auto range)
±1.5%rdg ±3dgt[45 - 500Hz]
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range)
±0.5%rdg ±4dgt (600Ω),
±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ)
±1.5%rdg ±3dgt (40MΩ)
Continuity buzzer 600Ω (Buzzer sounds below 90Ω)
Diode test Open-loop voltage: < 3.0V
Capacitance 60.00/600.0nF/6.000/60.00/600.0/1000µF
±2.0%rdg ±5dgt (60/600nF)
±5.0%rdg ±5dgt (6/60/600/1000µF)
Frequency ACV 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt
ACA 99.99/999.9Hz/9.999kHz ±0.1%rdg ±3dgt
DUTY 10 - 90% ±1.0%rdg ±3dgt [50/60Hz]
Applicable standards IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V
IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS)
Power source R03 (1.5V) × 2
Dimensions 155(L) × 75(W) × 40(D)mm
Weight 250g Approx. (including batteries)
Included Accessories Wing-type holder, Flat-type holder, 7066A (Test leads),
8919 (Ceramic fuse [10A/600V]) × 1 (included),
9097 (Carrying case), R03 × 2, Instruction manual
Optional Accessories 7234 (Alligator clip), 8161 (AC clamp adaptor)
8115 (AC/DC clamp sensor), 9189 (Magnet hanger strap)

 

MODEL 1009

Digital Multimeters

MODEL 1009

 

MODEL 1009
CE
 
• Display : 4000 counts.
• Auto range and manual range selector provided.
(with range hold feature)
• Resistance range provides audible continuity test.
• Automatically turns power off in about 30 minutes to conserve battery life.
• Direct current measurement up to 10A AC and DC.
• With Holster.

DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DUTY DATAHOLDRelative AutoPowerOff

 

 
DC V 400mV/4/40/400/600V (Input Impedance 10MΩ) ±0.6%rdg±4dgt (400mV/4/40/400V) ±1.0%rdg±4dgt (600V)
AC V 400mV/4/40/400/600V (Input Impedance 10MΩ) ±1.6%rdg±4dgt (20 - 400mV) ±1.3%rdg±4dgt (4/40V) ±1.6%rdg±4dgt (400/600V)
DC A 400/4000µA/40/400mA/4/10A ±2.0%rdg±4dgt
(400/4000µA)±1.0%rdg±4dgt
(40/400mA) ±1.6%rdg±4dgt (4/10A)
AC A 400/4000µA/40/400mA/4/10A ±2.6%rdg±4dgt
(400/4000µA) ±2.0%rdg±4dgt (40/400mA/4/10A)
Ω 400Ω/4/40/400kΩ/4/40MΩ ±1.0%rdg±4dgt (400Ω/4/40/400kΩ/4MΩ) ±2.0%rdg±4dgt (40MΩ)
Continuity buzzer 400Ω (Buzzer sounds below 70Ω)
Diode test 1.5V Release Voltage:Approx. 0.4mA Test Current
Capacitance 40/400nF/4/40/100µF
Frequency 5.12/51.2/512Hz/5.12/51.2/512kHz/5.12/10MHz
DUTY 0.1 - 99.9% (Pulse width/Pulse period) ±2.5%±5dgt
Applicable standards IEC 61010-1 CAT III 300V
IEC 61010-2-031
IEC 61326
Power source R6 (1.5V) × 2
Dimensions 161(L) × 82(W) × 50(D)mm
Weight Approx. 280g
Included Accessories 7066A (Test leads)
8919 (Ceramic fuse [10A/600V])× 1
8923 (Fuse [0.5A/600V])× 1
R6× 2
Instruction Manual
Optional Accessories 7234 (Crocodile clip test lead)
9095 (Carrying case)

 

KEW 1020R

Kyoritsu Indonesia - Jual Digital Multimeters KEW 1020R

KEW 1020R

NEW

 

KEW 1020R
CE
 
• Large display with 6000 counts and Backlight
• True-RMS
• MIN/MAX function
• Rugged and reliable
• Clamp sensor mode
• IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V

TRUE RMS CAT4 300V CAT3 600V DCACV Resistance Continuitybuzzer Diode Capacitance Frequency DUTY Backlight DATAHOLD Relative MAX/MIN AutoPowerSave

 

 
DC V 6.000/60.00/600.0/1000V (auto range)
±0.5%rdg ±3dgt (6/60/600V)
±0.8%rdg ±3dgt (1000V)
DC mV 600.0mV
±1.5%rdg ±3dgt
DC Clamp Sensor 60.00/200.0A (auto range)
±1.5%rdg ±3dgt + Sensor accuracy
AC V 6.000/60.00/600.0/1000V (auto range)
±1.0%rdg ±3dgt [40 - 500Hz] (6/60/600V)
±1.3%rdg ±3dgt [40 - 500Hz] (1000V)
AC mV 600.0mV
±2.0%rdg ±3dgt [40 - 500Hz]
AC Clamp Sensor 60.00/200.0A (auto range)
±2.0%rdg ±3dgt + Sensor accuracy [40 - 500Hz]
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ (auto range)
±0.5%rdg ±4dgt (600Ω)
±0.5%rdg ±2dgt (6/60/600kΩ/6MΩ)
±1.5%rdg ±3dgt (40MΩ)
Continuity buzzer 600Ω (Buzzer sounds below 90Ω)
Diode test Open-loop voltage: < 3.0V
Capacitance 60.00/600.0nF/6.000/60.00/600.0/1000µF
±2.0%rdg ±5dgt (60/600nF)
±5.0%rdg ±5dgt (6/60/600/1000µF)
Frequency 99.99/999.9Hz/9.999/99.99kHz ±0.1%rdg ±3dgt
DUTY 10.0 - 90.0% ±1.0%rdg ±3dgt [50/60Hz]
Applicable standards IEC 61010-1 CAT IV 300V / CAT III 600V / CAT II 1000V
IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 (EMC), EN 50581 (RoHS)
Power source R03 (1.5V) × 2
Dimensions 155(L) × 75(W) × 40(D)mm
Weight 250g Approx. (including batteries)
Included Accessories Wing-type holder
7066A (Test leads)
R03 × 2, Instruction manual
Optional Accessories 7234 (Alligator clips)
8161 (AC Clamp sensor)
8115 (AC/DC Clamp sensor)
9189 (Magnet hanger strap)