Home  //  Products  //  Clamp Meters  //  MODEL 2412  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 1019R

Kyoritsu Indonesia - Jual Digital Multimeters KEW 1019R

KEW 1019R

NEW

 

KEW 1019R
CE
 
• Elegant shiny-black finish
• Comes with user-friendly Hard case
• Large Display
• Accurate reading with True-RMS technology
• Electronic protection (no fuse!) on ohm and continuity ranges
• Safety Standard IEC 61010-1 / 61010-031 / 61010-2-033 CAT III 300V / CAT II 600V

TRUE RMS DCACV Resistance Continuitybuzzer Capacitance Relative AutoPowerSave

 

DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±0.8%rdg ±5dgt (600.0mV/6.000/60.00V)
±1.0%rdg ±5dgt (600.0V)
AC V [RMS] 6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.3%rdg±5dgt (6.000/60.00V) (50/60Hz)
±1.7%rdg±5dgt (6.000/60.00V) (45 - 500Hz)
±1.6%rdg±5dgt (600.0V) (50/60Hz)
±2.0%rdg±5dgt (600.0V) (45 - 500Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ
±1.0%rdg±5dgt (600.0Ω/6.000/60.00/600.0kΩ/6.000MΩ)
±2.5%rdg±5dgt (40.00MΩ)
Continuity buzzer 600.0Ω (Buzzer threshold value 60Ω or less)
Capacitance 6.000/60.00/600.0nF/6.000/60.00/600.0µF
±3.5%rdg±50dgt (6.000nF)
±3.5%rdg±10dgt (60.00nF)
±3.5%rdg±5dgt (600.0nF/6.000/60.00µF)
±4.5%rdg±5dgt (600.0µF)
Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2
IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2
Power source CR2032 (3V) × 1
Approx. 120 hours, Auto sleep: approx: 15 minutes
Dimensions 126(L) × 85(W) × 18(D)mm
Weight Approx. 135g (including hard case, battery)
Included Accessories 9188 (Hard case), CR2032 × 1, Instruction manual

 

KEWMATE 2012R

Digital Multimeter with AC/DC Clamp Sensor

KEWMATE 2012R

 

KEWMATE 2012R
CE
 
• Innovative Multimeters with current measurements up to 120A AC/DC
• Unique Open Jaw technology for AC/DC current measurements
• Very compact and as reliable as a tradictional full size multimeter

TRUE RMS φ12 MAX120A DCACV DCACA Resistance Continuitybuzzer Diode Capacitance Frequency DATAHOLD AutoPowerSave

 

DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 6.000/60.00/600.0V (Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45 - 400Hz)
DC A 60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.00/120.0A
±2.0%rdg±5dgt (45 - 65Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Continuity buzzer Buzzer sounds below 35±25Ω
Diode test 2V±3.0%rdg±5dgtOpen-loop voltage: approx. 2.7V
Capacitance 400.0nF/4.000/40.00µF
±2.5%rdg±10dgt
Frequency (AC A)
100/400Hz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (400Hz)
(DC A)
100/1000Hz/10/100/300.0kHz ±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)
(Input sensitivity
Current: more than 6A
Voltage: more than 6V [- 10kHz]/more than 20V [10k - 300kHz])
Conductor size Ø12mm max.
Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326
Power source R03 (1.5V) × 2
* Continuous measuring time:
DCV: approx. 150hours, ACA: approx. 25hours
(Auto power save: approx. 15 minutes)
Dimensions 128 (L) × 92 (W) × 27 (D) mm
Weight 220g approx. (including batteries)
Included Accessories R03 (1.5V) × 2, Instruction manual
Optional Accessories 9107 (Carrying case [Soft])

 

KEWMATE 2000

Digital Multimeter with AC/DC Clamp Sensor

KEWMATE 2000

KEWMATE 2000
CE
 
• Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
  • φ6 MAX60A DCACV DCACA Resistance Continuitybuzzer Frequency DATAHOLD AutoPowerSave
How to put test lead in.

DC V 340mV/3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±4dgt
AC V 3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±5dgt [50 - 400Hz]
DC A 60A ±2%rdg±5dgt
AC A 60A ±2%rdg±5dgt (50/60Hz)
Ω 340Ω/3.4/34/340kΩ/3.4/34MΩ
±1%rdg±3dgt (0 - 340kΩ)
±5%rdg±5dgt (3.4MΩ)
±15%rdg±5dgt (34MΩ)
Continuity buzzer Buzzer sounds below 30±10Ω
(Continuity buzzer works on 340Ω range only)
Frequency (AC A) 3.4/10kHz ±0.1%rdg±1dgt
(AC V) 3.4/34/300kHz ±0.1%rdg±1dgt
(Input sensitivity Current: more than 15A, Voltage: more than 30V)
Conductor size Ø6mm max.
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1
Power source R03 (DC 1.5V) × 2
* Continuous measuring time: approx. 45 hours
(Auto power save: approx. 10 minutes)
Dimensions 128(L) × 87(W) × 24(D)mm
Weight 210g approx.
Included Accessories R03 (DC 1.5V) × 2, Instruction Manual
Optional Accessories 9107 (Carrying case [Soft])

 

KEWMATE 2001

Digital Multimeter with AC/DC Clamp Sensor

KEWMATE 2001

KEWMATE 2001
CE
 
• Capable of measuring AC and DC currents up to 100A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
  • φ10 MAX100A DCACV DCACA Resistance Continuitybuzzer Frequency DATAHOLD AutoPowerSave
How to put test lead in.

DC V 340mV/3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±4dgt
AC V 3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±5dgt [50 - 400Hz]
DC A 100A ±2%rdg±5dgt
AC A 100A ±2%rdg±5dgt (50/60Hz)
Ω 340Ω/3.4/34/340kΩ/3.4/34MΩ
±1%rdg±3dgt (0 - 340kΩ)
±5%rdg±5dgt (3.4MΩ)
±15%rdg±5dgt (34MΩ)
Continuity buzzer Buzzer sounds below 30±10Ω
(Continuity buzzer works on 340Ω range only)
Frequency (AC A) 3.4/10kHz ±0.1%rdg±1dgt
(AC V) 3.4/34/300kHz ±0.1%rdg±1dgt
(Input sensitivity Current: more than 25A, Voltage: more than 30V)
Conductor size Ø10mm max.
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1
Power source R03 (DC 1.5V) × 2
* Continuous measuring time: approx. 45 hours
(Auto power save: approx. 10 minutes)
Dimensions 128(L) × 91(W) × 27(D)mm
Weight 220g approx
Included Accessories R03 (DC 1.5V) × 2, Instruction Manual
Optional Accessories 9107 (Carrying case [Soft])

 

206778
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
73
84
747
205067
2388
5007
206778

Your IP: 18.210.22.132