| DC V | 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ) ±0.8%rdg ±5dgt (600.0mV/6.000/60.00V) ±1.0%rdg ±5dgt (600.0V) |
|---|---|
| AC V [RMS] | 6.000/60.00/600.0V (Input impedance: approx. 10MΩ) ±1.3%rdg±5dgt (6.000/60.00V) (50/60Hz) ±1.7%rdg±5dgt (6.000/60.00V) (45 - 500Hz) ±1.6%rdg±5dgt (600.0V) (50/60Hz) ±2.0%rdg±5dgt (600.0V) (45 - 500Hz) |
| Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ ±1.0%rdg±5dgt (600.0Ω/6.000/60.00/600.0kΩ/6.000MΩ) ±2.5%rdg±5dgt (40.00MΩ) |
| Continuity buzzer | 600.0Ω (Buzzer threshold value 60Ω or less) |
| Capacitance | 6.000/60.00/600.0nF/6.000/60.00/600.0µF ±3.5%rdg±50dgt (6.000nF) ±3.5%rdg±10dgt (60.00nF) ±3.5%rdg±5dgt (600.0nF/6.000/60.00µF) ±4.5%rdg±5dgt (600.0µF) |
| Applicable standards | IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2 IEC 61010-2-033, IEC 61010-031, IEC 61326-2-2 |
| Power source | CR2032 (3V) × 1 Approx. 120 hours, Auto sleep: approx: 15 minutes |
| Dimensions | 126(L) × 85(W) × 18(D)mm |
| Weight | Approx. 135g (including hard case, battery) |
| Included Accessories | 9188 (Hard case), CR2032 × 1, Instruction manual |
![]()
| DC V | 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ) ±1.0%rdg±3dgt |
|---|---|
| AC V | 6.000/60.00/600.0V (Input impedance: approx.10MΩ) ±1.5%rdg±5dgt (45 - 400Hz) |
| DC A | 60.00/120.0A ±2.0%rdg±8dgt (60A) ±2.0%rdg±5dgt (120A) |
| AC A | 60.00/120.0A ±2.0%rdg±5dgt (45 - 65Hz) |
| Ω | 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ ±1.0%rdg±5dgt (600Ω/6/60/600kΩ) ±2.0%rdg±5dgt (6MΩ) ±3.0%rdg±5dgt (60MΩ) |
| Continuity buzzer | Buzzer sounds below 35±25Ω |
| Diode test | 2V±3.0%rdg±5dgtOpen-loop voltage: approx. 2.7V |
| Capacitance | 400.0nF/4.000/40.00µF ±2.5%rdg±10dgt |
| Frequency | (AC A) 100/400Hz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (400Hz) (DC A) 100/1000Hz/10/100/300.0kHz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz) (Input sensitivity Current: more than 6A Voltage: more than 6V [- 10kHz]/more than 20V [10k - 300kHz]) |
| Conductor size | Ø12mm max. |
| Applicable standards | IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2 IEC 61010-031, IEC 61010-2-032, IEC 61326 |
| Power source | R03 (1.5V) × 2 * Continuous measuring time: DCV: approx. 150hours, ACA: approx. 25hours (Auto power save: approx. 15 minutes) |
| Dimensions | 128 (L) × 92 (W) × 27 (D) mm |
| Weight | 220g approx. (including batteries) |
| Included Accessories | R03 (1.5V) × 2, Instruction manual |
| Optional Accessories | 9107 (Carrying case [Soft]) |


| DC V | 340mV/3.4/34/340/600V (Input Impedance: 10MΩ) ±1.5%rdg±4dgt |
|---|---|
| AC V | 3.4/34/340/600V (Input Impedance: 10MΩ) ±1.5%rdg±5dgt [50 - 400Hz] |
| DC A | 100A ±2%rdg±5dgt |
| AC A | 100A ±2%rdg±5dgt (50/60Hz) |
| Ω | 340Ω/3.4/34/340kΩ/3.4/34MΩ ±1%rdg±3dgt (0 - 340kΩ) ±5%rdg±5dgt (3.4MΩ) ±15%rdg±5dgt (34MΩ) |
| Continuity buzzer | Buzzer sounds below 30±10Ω (Continuity buzzer works on 340Ω range only) |
| Frequency | (AC A) 3.4/10kHz ±0.1%rdg±1dgt (AC V) 3.4/34/300kHz ±0.1%rdg±1dgt (Input sensitivity Current: more than 25A, Voltage: more than 30V) |
| Conductor size | Ø10mm max. |
| Applicable standards | IEC 61010-1 CAT III 300V Pollution degree 2 IEC 61010-031, IEC 61010-2-032, IEC 61326-1 |
| Power source | R03 (DC 1.5V) × 2 * Continuous measuring time: approx. 45 hours (Auto power save: approx. 10 minutes) |
| Dimensions | 128(L) × 91(W) × 27(D)mm |
| Weight | 220g approx |
| Included Accessories | R03 (DC 1.5V) × 2, Instruction Manual |
| Optional Accessories | 9107 (Carrying case [Soft]) |
We have 44 guests and no members online