| DC V | 400mV/4/40/400/600V (Input Impedance 10MΩ) ±0.8%rdg±5dgt (400mV/4/40/400V) ±1.0%rdg±5dgt (600V) |
|---|---|
| AC V | 4/40/400/600V (Input Impedance 10MΩ) ±1.3%rdg±5dgt (4/40V) ±1.6%rdg±5dgt (400/600V) |
| Ω | 400Ω/4/40/400kΩ/4/40MΩ ±1.0%rdg±5dgt (400Ω/4/40/400kΩ/4MΩ) ±2.5%rdg±5dgt (40MΩ) |
| Continuity buzzer | 400Ω (Buzzer sounds below 120Ω) |
| Diode test | 4V Release Voltage:Approx. 0.4mA Test Current |
| Capacitance | 4nF/40nF/400nF/4µF/40µF/200µF |
| Frequency | 10/100Hz/1/10/100/200kHz |
| Applicable standards | IEC 61010-1 CAT III 300V IEC 61010-2-031 IEC 61326-1 |
| Display | 4000 counts |
| Power source | LR44 (1.5V) × 2 |
| Dimensions | 107(L) × 54(W) × 10(D)mm |
| Weight | 70g approx. |
| Included Accessories | LR44× 2 Instruction Manual 1018 (Soft Case) 1018H (Hard Case) |

| DC V | 600.0mV/6.000/60.00/600.0/600V (Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V) |
|---|---|
| AC V | 6.000/60.00/600.0/600V (Input Impedance: 10MΩ) ±1.5%±5dgt (6.000V) ±1.2%±3dgt (60.00/600.0V) ±1.5%±5dgt (600V) |
| DC A | 600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A) |
| AC A | 600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A) |
| Ω | 600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt (600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ) |
| Continuity buzzer | 0 - 600Ω (Buzzer sounds below 100Ω) |
| Diode test | 2.8V Release Voltage:Approx. 0.4mA Test Current |
| Capacitance | 40/400nF/4/40/400/4000µF |
| Frequency | 10/100/1000Hz/10/100/1000kHz/10MHz |
| DUTY | 0.1 - 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz) |
| Applicable standards | IEC 61010-1 CAT III 300V Pollution degree 2 IEC 61010-1 CAT II 600V Pollution degree 2 IEC 61010-031 IEC 61326 |
| Display | 6040 Counts |
| Power source | R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes) |
| Dimensions | 161(L) × 82(W) × 50(D)mm |
| Weight | Approx. 280g |
| Included Accessories | 7066A (Test leads) 0.8A/600V (Ceramic Fuse) × 1built-in 10A/600V (Ceramic Fuse) × 1built-in R6 × 2 Instruction Manual |
| Optional Accessories | 7234 (Crocodile clip test lead) 9095 (Carrying case) |

| DC V | 600.0mV/6.000/60.00/600.0/600V (Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V) |
|---|---|
| AC V | 6.000/60.00/600.0/600V (Input Impedance: 10MΩ) ±1.0%±3dgt (6.000/60.00/600.0V)±1.5%±3dgt (600V) |
| DC A | 600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A) |
| AC A | 600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A) |
| Ω | 600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt (600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ) |
| Continuity buzzer | 0 - 600Ω (Buzzer sounds below 100Ω) |
| Diode test | 2.8V Release Voltage:Approx. 0.4mA Test Current |
| Capacitance | 40/400nF/4/40/400/4000µF |
| Frequency | 10/100/1000Hz/10/100/1000kHz/10MHz |
| DUTY | 0.1 - 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz) |
| Temperature | -50 - 300ºC (-58 - 572ºF) (with the use of Temperature probe 8216) Note: KEW 1011 can measure max. 700ºC In order to measure over 300ºC, please use a K-type temperature probe available in the market. |
| Applicable standards | IEC 61010-1 CAT III 300V Pollution degree 2 IEC 61010-1 CAT II 600V Pollution degree 2 IEC 61010-031 IEC 61326 |
| Display | 6040 Counts |
| Power source | R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes) |
| Dimensions | 161(L) × 82(W) × 50(D)mm |
| Weight | Approx. 280g |
| Included Accessories | 7066A (Test leads) 8216 (K-type Temperature probe) 0.8A/600V (Ceramic Fuse) × 1built-in 10A/600V (Ceramic Fuse) × 1built-in R6 × 2Instruction Manual |
| Optional Accessories | 7234 (Crocodile clip test lead) 9095 (Carrying case) |
We have 43 guests and no members online