| Earth resistance Auto range | 20.00/200.00/1500Ω ±1.5%±0.05Ω(0.00 - 20.99Ω) ±2%±0.5Ω(16.0 - 99.9Ω) ±3%±2Ω(100.0 - 209.9Ω) ±5%±5Ω(160 - 399Ω) ±10%±10Ω(400 - 599Ω) |
|---|---|
| AC current (50Hz/60Hz) Auto range | Values are displayed, but accuracy isn't guaranted(600 - 1580Ω) 100.0/1000mA/10.00/30.0A ±2%±0.7mA(0.0 - 104.9mA) ±2%(80mA - 31.5A) |
| Operating indication | Earth resistance function : Constant voltage injection Current detection (Frequency : Approx.2400Hz) Dual Integration AC current function : Successive approximation |
| Over-range indication | "OL"is displayed when input exceeds the upper limit of a measuring range |
| Response time | Approx. 7 seconds (Earth resistance) Approx. 2 seconds (AC current) |
| Sample rate | Approx. 1 times per second |
| Communication Interface | Bluetooth Ver2.1 + EDR Class2 |
| Current consumption | Approx. 50mA (max.100mA) |
| Measurement time | Approx.5 hours (when R6 is used) Approx. 21 hours (when LR6 is used) |
| Auto power-off | Turns power off about 10 minutes after the last button operation. |
| Conductor size | Approx.Ø32mm |
| Applicable standards | IEC 61010-1 CAT Ⅳ 300V Pollution degree2 IEC 61010-2-032, IEC 61326 (EMC) |
| Power source | DC6V : R6(sizeAA manganese battery) x 4 or LR6 (sizeAA alkaline battery) x 4 |
| Dimensions | 246(L)×120(W)×54(D)mm |
| Weight | Approx. 780g (including batteries) |
| Included Accessories | LR6 x 4, Instruction manual 8304 (Resister for operation check) 9167 (Carrying case[Hard]) |



| Earth resistance Auto range | 20.00/200.0/1500Ω ±1.5%±0.05Ω(0.00 - 20.99Ω)* ±2%±0.5Ω(16.0 - 99.9Ω) ±3%±2Ω(100.0 - 209.9Ω) ±5%±5Ω(160 - 399Ω) ±10%±10Ω(400 - 599Ω) |
|---|---|
| AC current (50Hz/60Hz) Auto range | Values are displayed, but accuracy isn't guaranted(600 - 1580Ω) 100.0/1000mA/10.00/30.0A ±2%±0.7mA(0.0 - 104.9mA) ±2%(80mA - 31.5A) |
| Operating indication | Earth resistance function : Constant voltage injection Current detection (Frequency : Approx.2400Hz) Dual Integration AC current function : Successive approximation |
| Over-range indication | "OL"is displayed when input exceeds the upper limit of a measuring range |
| Response time | Approx. 7 seconds (Earth resistance) Approx. 2 seconds (AC current) |
| Sample rate | Approx. 1 times per second |
| Current consumption | Approx. 50mA (max.100mA) |
| Measurement time | Approx.12 hours (when R6 is used) Approx.24 hours (when LR6 is used) |
| Auto power-off | Turns power off about 10 minutes after the last button operation. |
| Conductor size | Approx. Ø32mm |
| Applicable standards | IEC 61010-1 CAT Ⅳ 300V Pollution degree2 IEC 61010-2-032, IEC 61326 (EMC) |
| Power source | DC6V : R6(sizeAA manganese battery) x 4 or LR6 (sizeAA alkaline battery) x 4 |
| Dimensions | 246(L)×120(W)×54(D)mm |
| Weight | Approx. 780g (including batteries) |
| Included Accessories | R6 x 4, Instruction manual 8304 (Resister for operation check) 9166 (Carrying case[Hard]) |


| Function | Range | Resolution | Measuring range | Accuracy |
|---|---|---|---|---|
| Earth resistance Re (Rg at ρ measurement) |
2Ω | 0.001Ω | 0.03 - 2.099Ω | ±2%rdg±0.03Ω |
| 20Ω | 0.01Ω | 0.03 - 20.99Ω | ±2%rdg±5dgt (*1) | |
| 200Ω | 0.1Ω | 0.3 - 209.9Ω | ||
| 2000Ω | 1Ω | 3 - 2099Ω | ||
| 20kΩ | 10Ω | 0.03k - 20.99kΩ | ||
| 200kΩ | 100Ω | 0.3k - 209.9kΩ | ||
| Auxiliary earth resistance Rh, Rs |
8% of Re+Rh+Rs | |||
| Earth resistivity ρ |
2Ω | 0.1Ω·mm - 1Ω·m Autoranging |
0.2 - 395.6Ω·m | ρ=2×π×a×Rg (*2) |
| 20Ω | 0.2 - 3956Ω·m | |||
| 200Ω | 20 - 39.56kΩ·m | |||
| 2000Ω | 0.2 - 395.6kΩ·m | |||
| 20kΩ | 2.0 - 1999kΩ·m | |||
| 200kΩ | ||||
| Series interference voltage Ust (A.C only) (*3) |
50V | 0.1V | 0 - 50.9Vrms | ±2%rdg±2dgt (50/60Hz) |
| ±3%rdg±2dgt (40 - 500Hz) | ||||
| Frequency Fst |
Autoranging | 0.1Hz 1Hz |
40Hz - 500Hz | ±1%rdg±2dgt |
| Measuring method | Earth resistance: Fall-of-potential method (currents and voltages measured via the Probes) Measurement method of Earth Resistivity (ρ): Wenner 4-pole method Series interference voltage (earth voltage) RMS Rectifier (between the E-S Terminals) |
|||
| Memory capacity | 800 data | |||
| Communication Interface | Model 8212-USB Optical Adaptor | |||
| LCD | Dot-matrix 192×64 monochrome | |||
| Over-range Indication | "OL" | |||
| Overload Protection | between E-S(P) and between E-H(C) terminals AC280V / 10 sec. | |||
| Applicable standards | IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2 IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54) |
|||
| Power source | DC12V : sizeAA manganese dry battery (R6) × 8 (Auto power off: approx. 5 minutes) |
|||
| Dimensions | 167(L) × 185(W) × 89(D) mm | |||
| Weight | approx. 900g (including batteries) | |||
| Accessories | 7229A (Earth precision measurement), 7238A (Simplified measurement test leads), 8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total), 8200-04 (Cord reel [4 pcs])×1 set, 8212-USB (USB adaptor with "KEW Report(Software)"), 9121 (Shoulder strap), 9125 (Carrying case), R6 × 8, Instruction manual, Calibration certificate |
|||
| Optional | 8212-RS232C (RS232C adaptor with "KEW Report(Software)") | |||