| Continuity Testing | |
|---|---|
| Measuring Ranges | 0 - 19.99 and 10.0 - 199.9Ω (2 auto ranges) |
| Open Circuit Voltage | > 4V (as per IEC 364) |
| Short Circuit Current | > 200mA DC (as per IEC 364) |
| Accuracy | ±(3% + 3dgt) |
| Loop Impedance Testing | |
| Rated Voltage | 230V AC +10%-15% (50Hz) |
| Voltage Measuring Range | 100-250V AC (50Hz) |
| Impedance Range Nominal Test Current |
20/2000Ω 25A (20Ω range) 15mA (2000Ω range) |
| Test Period | 1/2 cycle (10ms) |
| Accuracy | 20Ω range : ±(3% + 8dgt) 2000Ω range : ±(3% + 8dgt) |
| Insulation Testing | |
| Measuring Ranges | 0 - 19.99 and 10.0 - 199.9MΩ (2 auto ranges) |
| Test Voltage | 500V DC |
| Output Voltage on Open Circuit |
570V DC±6% |
| Rated Current | > 1mA (as per IEC 364) |
| Accuracy | ± (3% + 3dgt) |
| RCD Testing | |
| Rated Voltage | 230V AC +10%-15% (50Hz) |
| Trip Current Settings | RCD × 1/2: 5, 15, 50, 150, 250mA RCD × 1: 10, 30, 100, 300, 500mA |
| Trip Current Duration | RCD × 1/2 × 1: 2000ms |
| Fast Trip | 150mA |
| Accuracy | Trip current ±3% of test current at 230V. Trip time ±(3% + 3dgt) |
| Safety Standard | IEC 61010-1 CAT III 300V Pollution Degree 2 IEC 61010-2-031 IEC 61557 |
|---|---|
| Power source | R6 (AA) (1.5V) × 8 |
| Dimensions | 175(L) × 115(W) × 86(D)mm |
| Weight | 780g approx. |
| Included Accessories | 7122B (Test leads) KAMP10* (Test Lead with IEC Connector) Pouch for Test leads Shoulder Strap Shoulder Pad R6 (AA) × 8 Instruction Manual |
| Optional Accessories | 7133B (Distribution board test leads) |

Continuity and Insulation Testing
• Live circuit warning LED:
Immediate illumination of a warning lamp if the circuit under test is live
• Auto Discharge:
Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing
• Integral overload protection on internal continuity and insulation test circuitry
• Autoranging
• 500V DC test voltage for insulation tests
• 200mA short circuit current on continuity ranges
Loop and RCD Testing
• Wiring connection check LED's:
Immediate indication if wiring of circuit under test is correct
• Overheat Protection:
Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement
• Supply Voltage Indication:
Can display supply voltage value in loop impedance mode
• Low Current Loop Impedance Test:
Short duration low test current will prevent tripping of many passive RCDs
• Auto Data Hold:
Retains displayed reading for set period following test
• Phase Angle Selection:
Selection of test current from +ve or -ve half cycle of waveform can prevent tripping of polarized type RCDs

• Continuity: 20/200Ω, 200mA Test Current
• Insulation: 500/1000V, 20/200MΩ, 1mA Rated Test Current
• Loop Impedance: 20/2000Ω, 15mA Test Current at 2000Ω (No RCD Trip)
• RCD: 10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
• Test of a large kind of RCD's:
Standard, Selective, AC and A (DC sensitive breakers)
• Uc (Contact Voltage): 100V
• Designed to IEC 61010-1, IEC 61557
• Data Memory: 300 measured results
• The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

• Complies with IEC 61557
• Designed to IP 54 Rating
• Live circuit and wiring connection check LED's
• Triple ranges insulation tests at 250, 500 and 1000V
• Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range (No RCD Trip)
• Phase angle selection on RCD ranges
• Polarity switch for continuity tests
• Auto-null facility for continuity tests
• Earth probe for loop impedance testing on extraneous metalwork
• Contact Voltage Reading
• Test of a large kind of RCD's:
Standard, Selective, AC and A (DC sensitive breakers)

The KEW 6016 Multi-Function tester performs 10 functions
in one instrument.
• Continuity tester
• Insulation resistance tester
• Loop impedance tester
• PSC tester
• PFC tester
• RCD tester
• Earth tester
• Phase rotation tester
• Voltage measurement
• Frequency measurement

• Designed to meet IEC 61010-1 CAT III 600V
• Test leads with remote control switch.
(For insulation&Simplified Earth Test)
• Back light function.
• Color coded scales and range switch position for easy reading.
• Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
• Can be hung around the neck for both hand’s operation.


• Correct measuring for Insulation resistance even if the panel is under generating power
• Waterproof design: Can measure under the bad weather condition
• Memory function up to 1000 data
• Luminescence button and Backlight
Jual


| Wiring connections | 1P2W, 1P3W, 3P3W, 3P4W | |
|---|---|---|
| Measurements and parameters | Voltage, Current, Frequency, Active power, Reactive power, Apparent power,Active energy, Reactive energy, Apparent energy, Power factor (cos θ), Neutral current, Demand, Harmonics, Quality (Swell/Dip/Interruption, Transients/Over voltage, Inrush current, Unbalance rate), Capacitance calculation for PF correction unit, Flicker |
|
| Voltage (RMS) | ||
| Range | 600.0 / 1000V | |
| Accuracy | ±0.2%rdg±0.2%f.s. (sine wave, 40 - 70Hz) | |
| Allowable input | 1 - 120% of each range (rms). 200% of each range (peak) | |
| Display range | 0.15 - 130% of each range | |
| Crest factor | 3 or less | |
| Sampling speed of Voltage transient | 24µs | |
| Current (RMS) | ||
| Range | 8128 ( 50A type ) : 5 / 50A / AUTO 8127 ( 100A type ) : 10 / 100A / AUTO 8126 ( 200A type ) : 20 / 200A / AUTO 8125 ( 500A type ) : 50 / 500A / AUTO 8124/8130 ( 1000A type ) : 100 / 1000A / AUTO 8146/8147/8148 ( 10A type ) : 1 / 10A / AUTO 8129 ( 3000A type ) : 300 / 1000 / 3000 |
|
| Accuracy | ±0.2%rdg±0.2%f.s. + accuracy of clamp sensor (sine wave, 40 - 70Hz) | |
| Allowable input | 1 - 110% of each range (rms). 200% of each range (peak) | |
| Display range | 0.15 - 130% of each range | |
| Crest factor | 3 or less | |
| Active power | ||
| Accuracy | ±0.3%rdg±0.2%f.s. + accuracy of clamp sensor (power factor 1, sine wave, 40 - 70Hz) |
|
| Influence of power factor | ±1.0%rdg (reading at power factor 0.5 against power factor 1) | |
| Frequency meter range | 40 - 70Hz | |
| Power supply (AC Line) | AC100 - 240V / 50 - 60Hz / 7VA max | |
| Power supply (DC battery) | Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6 Battery life approx. 3h (LR6, Backlight OFF) |
|
| Internal memory | FLASH memory (4MB) | |
| PC card interface | SD card (2GB) | |
| PC communication interface | USB Ver2.0, Bluetooth Ver2.1 + EDR Class2 | |
| Display | 320 × 240 (RGB) Pixel, 3.5inch color TFT display | |
| Display update period | 1 sec | |
| Applicable standards | IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V Pollution degree 2 IEC 61010-2-030, IEC 61010-031, IEC 61326, EN 50160 IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7 |
|---|---|
| Temperature and humidity range | 23±5ºC, less than 85% RH (without condensation) |
| Operating temperature & humidity range | 0 - +45ºC, less than 85% RH (without condensation) |
| Storage temperature & humidity range | -20 - +60ºC, less than 85% RH (without condensation) |
| Power supply (AC Line) | AC100 - 240V / 50 - 60Hz / 7VA max |
| Power supply (DC battery) | Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6 Battery life approx. 3h (LR6, Backlight OFF) |
| Dimensions | 175(L) × 120(W) × 68(D) mm |
| Weight | Approx. 900g |
| Included Accessories | 7141B (Voltage test lead) 7170 (Power cord) 7219 (USB cable) 8326-02 (SD card 2GB) 9125 (Carrying case for KEW 6315) 9135 (Carrying case for KEW 6315-03) Input terminal plate × 6, KEW Windows for KEW 6315 (software), Quick manual, Alkaline size AA battery (LR6) × 6 |
| Optional Accessories | 8124, 8125, 8126, 8127, 8128 (Load current clamp sensor) 8129, 8130 (Flexible clamp sensor) 8146, 8147, 8148 (Leakage and Load current clamp sensor) 8312 (Power supply adaptor) 9132 (Magnetci carrying case) |
We have 155 guests and no members online