JUAL PRODUK ROHDE & SCHWARZ

Jual Rohde and Schwarz dengan harga murah dan bergaransi

JUAL PRODUK FLIR INDONESIA HARGA MURAH

Jual Produk Flir dengan harga murah

Jual Anritsu Indonesia

Jual Anritsu dengan harga murah dan bergaransi resmi

Jual Keithley, Keithley Indonesia, Distributor Keithley, Harga Keithley, Keithley Murah

Jual Tekiro - Tekiro Indonesia

Distributor Tekiro Indonesia, Harga Tekiro, Tekiro Murah

Kikusui Indonesia - Ametek Indonesia

Kikusui Indonesia - Ametek Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Teledyne Lecroy Indonesia - Thomas & Betts Indonesia

Jual Alat Safety Indonesia

Jual Alat Safety Indonesia, Yotsugi Indonesia, Respirex Indonesia, Regeltex Indonesia, Bushnell Indonesia

Jual Ritz Telescopic Hot Stick - Sensorlink

Jual Ritz Telescopic Hot Stick ,Jual Sensorlink Indonesia dengan harga murah
Home  //  Others  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

MODEL 4118A

Jual Kyoritsu LOOP/PFC/PSC Testers MODEL 4118A

 

LOOP/PFC/PSC Testers

MODEL 4118A

 

MODEL 4118A
CE
 
• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 15mA LOOP measurement:
LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).
The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).
• Direct reading of Prospective Short Circuit Current (PSC).
• Safe voltage measurement function.
• Large custom digital display readout on all models.
• Measure low loop resistances(resolution of 0.01Ω)
• Automatic lock-out if test resister overheats.
• Large custom digital display readout .
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating
• Complies with IEC 61557

 

Front Cover

 

Loop Impedance Ranges 20/200/2000Ω
Loop Impedance Accuracy ±2%rdg±4dgt
AC Test Current 20Ω 25A
200Ω 2.3A
2000Ω 15mA
AC Test Period 20Ω (20ms)
200Ω (40ms)
2000Ω (280ms)
PSC Ranges 200A (2.3A 40ms)
2000A (25A 20ms)
20kA (25A 20ms)
PSC Ranges Accuracy Consider accuracy of Loop impedance
Voltage 110V-260V ±2%rdg±4dgt
Operating Voltage 230V+10% -15% (195V - 253V) 50Hz
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61557-1,-3
IEC 61010-2-031
IP Rating IEC 60529-IP54
Dimensions 167(L) × 185(W) × 89(D)mm
Weight 750g approx.
Accessories Molded plug test leads
7121B (Simplified measurement probe)
Pouch for test leads
9121 (Shoulder Strap)
Instruction Manual

 

KEW 5410

Jual RCD Testers KEW 5410

 

RCD Testers

KEW 5410

KEW 5410
CE
 
• Measurement of RCD trip time
 Conducting testing of rated residual non-operating currents at
 × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
• Measurement of trip out current
 Measuring trip out current by varying current automatically.
• Remote Test
 Enabling a user to hold the Test Leads with his both hands
 by locking the Test Button. Measurement will automatically
 start when the main voltage is detected.
• Voltage Measurement
 Carrying out a constant measurement of voltage in the
 stand-by mode at each Range.
• Auto-detection of Contact voltage
 Detecting the voltage to earth of Earth electrodes or
 Protective conductors during RCD test - when applying
 test currents - at measurement using EARTH in order to
 prevent electrical shocks caused by the damaged earth.
 Measurement will be ceased at AC50V or more.
• Dust- and Water-proof
 Dust- and Water-proof construction
 (designed to IEC 60529 IP54).
• Backlight
 Facilitating working at dimly illuminated locations.
 

Measurement of RCD trip time - Measurement of trip out current

Range× 5× 1× 1/2AUTO RAMP(mA)
Rated Voltage 100V±10%
200V-10%~+32%
400V±10%
50/60Hz
Test current 15/30/50/100mA 15/30/50/100/200/500mA 15/30/50/100/200/500mA
Measuring range Testing time
0ms~200ms
Testing time
0ms~2000ms
Testing time
0ms~2000ms
40% - 110% of lΔn
(goes up by 5%)
Testing time
300ms × 15steps
Accuracy
(Trip Time)
1%rdg±3dgt 1%rdg±3dgt 1%rdg±3dgt Test Current at each step
-4%~+4%

Accuracy
(Trip Time)

+2%~+8%dgt +2%~+8%dgt -8%~-2%dgt

Voltage Measurement

Measuring range 80V~450V 50/60Hz
Accuracy 2%rdg±4dgt
Applicable standards IEC 61010-1 Pollution degree2 CAT III 300V / CAT II 400V
IEC 61010-031
IEC 61557-1, 6
IEC 60529 (IP54)
Display 1999 counts (3 1/2digits), Large LCD
Operating temperature & humidity range 0ºC - 40ºC, relative humidity 85% (no condensation)
Storage temperature & humidity range -20ºC - 60ºC, relative humidity 85% (no condensation)
Insulation resistance 50MΩ or more / 1000V (between electrical circuit and enclosure)
Sleep Function (1)Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2) Backlight turns off in 1 minute after it lights up.
Power source DC 12V / Size AA battery R6 (SUM-3) × 8 pcs.
Dimensions 167(L)×186(W)×89(D)mm
Weight Approx. 965g (including batteries)
Possible number of Measurements 1200 times or more
(measure every 30 seconds at ×1/2 Range, lΔn=100mA)
Included Accessories 7128A (Test leads)
7129A (Test lead with alligator clip)
8017 (Long pin) × 2
Cord case, 9121 (Shoulder strap), Instruction manual,
Size AA battery R6 (SUM-3) × 8pcs.

 

MODEL 5406A

Jual Kyoritsu RCD Testers MODEL 5406A

 

RCD Testers

MODEL 5406A

MODEL 5406A
CE
 
• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 0 and 180 degree phase angle switch permits quick tests and consistent readings.
• Digital read-out of tripping time.
• Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
• Large custom digital display readout.
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating.
• Complies with IEC 61557
• Test of a large kind of RCD's: Standard, Selective, AC and A (DC sensitive breakers)
 
Rated Tripping Current 10/20/30/200/300/500mA
Fault Condition Settings × 1/2, × 1, × 5, × DC,
AUTO RAMP
Trip Current Duration 1000ms, 200ms (×5)
Lowest Resolution 1ms
Trip Time Accuracy ±0.6%rdg±4dgt
Operating Voltage 230V+10%-15%
(195V - 253V) 50Hz
Safety Standard IEC 61557-1,-6
IEC 61010-1 CAT III 300V
IEC 61010-2-031 Pollution Degree 2
Withstand Voltage 3700V AC for 1 minute
IP Rating IEC 60529-IP54
Dimensions 167(L) × 186(W) × 89(D)mm
Weight 800g approx.
Accessories Molded plug test leads
Pouch for test leads
9121 (Shoulder Strap)
Instruction Manual
Optional 7121B (Simplified measurement probe)

 