Home  //  Products  //  Clamp Meters  //  MODEL 2412  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 3122B

Jual High Voltage Insulation Testers KEW 3122B

High Voltage Insulation Testers

KEW 3122B

NEW

 

KEW 3122B
CE
 
• Extremely easy and simple operation
• Automatic ranges, indicated by individual LED's
• Newly-designed alligator clip
• It comes with a tough hard case
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V
(Photo: 3121B)

 

  • CAT4 300V CAT3 600V 5000V

 

 

 

Insulation Resistance

Test voltage 5000V
Measuring ranges 5GΩ/200GΩ (Auto-ranging)
Accuracy 0.2 - 100GΩ: ±5%rdg
0 - 0.2GΩ, 100GΩ - ∞:
±10%rdg or 0.5% of scale length

 

General

 

Applicable standards IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V
Pollution degree 2, IEC 61010-031, IEC 61326-1, 2-2
Power source DC12V : LR14/R14 × 8pcs
Dimensions 177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Hard case)
Weight 1.7kg approx.
Included Accessories 7165A (Line probe: 3m)
7264 (Earth cord: 3m)
7265 (Guard cord: 3m)
8019 (Hook type prod)
9183 (Carrying case[Hard])
LR14 (Alkaline battery size C) × 8
Instruction manual
Optional Accessories 7168A (Line probe with aligator clip: 3m)
7253 (Longer line probe with alligator clip: 15m)
8324 (Adaptor for recorder)

 

KEW 3121B

Jual High Voltage Insulation Testers KEW 3121B

High Voltage Insulation Testers

KEW 3121B

NEW

 

KEW 3121B
CE
 
• Extremely easy and simple operation
• Automatic ranges, indicated by individual LED's
• Newly-designed alligator clip
• It comes with a tough hard case
• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V

 

  • CAT4 300V CAT3 600V 2500V

 

 

 

Insulation Resistance

Test voltage 2500V
Measuring ranges 2GΩ/100GΩ (Auto-ranging)
Accuracy 0.1 - 50GΩ: ±5%rdg
0 - 0.1GΩ, 50GΩ - ∞:
±10%rdg or 0.5% of scale length

 

General

 

Applicable standards IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V
Pollution degree 2, IEC 61010-031, IEC 61326-1, 2-2
Power source DC12V : LR14/R14 × 8pcs
Dimensions 177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Hard case)
Weight 1.6kg approx.
Included Accessories 7165A (Line probe: 3m)
7264 (Earth cord: 3m)
7265 (Guard cord: 3m)
8019 (Hook type prod)
9182 (Carrying case[Hard])
LR14 (Alkaline battery size C) × 8
Instruction manual
Optional Accessories 7168A (Line probe with aligator clip: 3m)
7253 (Longer line probe with alligator clip: 15m)
8324 (Adaptor for recorder)

 

KEW 3023

Jual Digital Insulation / Continuity Testers KEW 3023

 

Digital Insulation / Continuity Testers

KEW 3023

KEW 3023
CE
AutoDischarge
 
• 3 functions in one unit, insulation test with 4 voltage ranges,
 continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
 on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
(Photo: 3021)
  • 100V 250V 500V 1000V DCACV Resistance Continuitybuzzer Backlight AutoPowerOff
 

Insulation resistance

Test voltage 100/250/500/1000V
Measuring range
(Auto range)
4.000/40.00/200.0MΩ (100V)
4.000/40.00/400.0/2000MΩ (250/500/1000V)
First effective measuring range 0.1 - 20MΩ (100V)
0.1 - 40MΩ (250V)
0.1 - 200MΩ (500V)
0.1 - 1000MΩ (1000V)
Mid-scale value 5MΩ (100/250V)
50MΩ (500/1000V)
Accuracy ±2%rdg±6dgt
Second effective measuring range lower 0 - 0.099MΩ
Second effective measuring range upper 20.01 - 200.0MΩ (100V)
40.01 - 2000MΩ (250V)
200.1 - 2000MΩ (500V)
1001 - 2000MΩ (1000V)
Accuracy ±5%rdg±6dgt
Rated current DC 1 - 1.2mA
Output short circuit current 1.5mA max

Ω/Continuity

Auto range 40.00/400.0Ω
Accuracy ±2%rdg±8dgt
Output voltage on open circuit 5V±20%
Output short circuit current DC 220±20mA
Fuse Quick acting ceramic fuse 0.5A/600V (Ø6.35×32mm)

AC Voltage

AC voltage range AC 20 - 600V (50/60Hz)
DC -20 - -600V/+20 - +600V
Accuracy ±3%rdg±6dgt

General

Applicable standards IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)
Power source R6 × 6 or LR6 × 6
Dimensions / Weight 105(L) × 158(W) × 70(D)mm / 600g approx
Included Accessories 7150A (Remote control switch set),
9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual
Optional Accessories 7115 (Extension Probe), 8016 (Hook type prod),
8923 (Fuse [0.5A/600V]), 9089 (Carrying Case)

 

KEW 3025A

Jual High Voltage Insulation Testers KEW 3025A

High Voltage Insulation Testers

KEW 3025A

NEW

 

KEW 3025A
CE  AutoDischarge
High Voltage Insulation Tester
• Short-Circuit Current up to 1.5mA
• Diagnosis Function of PI and DAR
• Newly-designed alligator clip
• It comes with a tough hard case
• Filter function reduces noise interference for obtaining stable measurement
• Large display with Bar Graph indication and backlight
• Live voltage warning
• Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
(Photo: 3125A)

 

  • CAT4 300V CAT3 600V DCACV Backlight AutoPowerOff 250V 500V 1000V 2500V

 

 

 

Insulation resistance

Rated voltage250V500V1000V2500V
Accuracy 0.0 - 100.0MΩ  0.0 - 99.9MΩ
80 - 1000M Ω  
0.0 - 99.9MΩ 
80 - 999MΩ
0.80 - 2.00G  Ω
 0.0 - 99.9MΩ 
 80 - 999MΩ
 0.80 - 9.99GΩ 
 8.0 - 100.0GΩ
±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt
Short circuit current 1.5mA
Output voltage  
 Accuracy ±10% -10 - +20% 0 - +20%
Monitor ±10%rdg±20V

Voltage measurement

Measuring range AC: 30 - 600V (50/60Hz), DC: ±30 - ±600V
Accuracy ±2%rdg±3dgt

 

General

 

Applicable standards IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2,
IEC 61010-031, IEC 61326-1, 2-2
Power source DC12V : LR14/R14 × 8pcs
Dimensions 177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Hard case)

Weight 3025A: 1.7kg approx. (including batteries)
4kg approx. (including accessories)
Included Accessories 7165A (Line probe: 3m), 7264 (Earth cord: 3m), 7265 (Guard cord: 3m),
8019 (Hook type prod), 9180 (3025A Hard case), 9181 (3125A Hard case),
LR14 (Alkaline battery size C) × 8, Instruction manual


Optional Accessories 7168A (Line probe with alligator clip: 3m),
7253 (Longer line probe with alligator clip: 15m),
8302 (Adaptor for recorder)

 

KEW 3022

Jual Digital Insulation / Continuity Testers KEW 3022

 

Digital Insulation / Continuity Testers

KEW 3022

KEW 3022
CE
AutoDischarge
 
• 3 functions in one unit, insulation test with 4 voltage ranges,
 continuity test, AC voltage measurement
• 200mA measuring current on continuity testing
• Comparator function with PASS / FAIL and buzzer
• 0Ω adjustment at continuity measuring range
• Memory function up to 99 data
• Backlight LCD provides easy reading in dark locations
• Safety lock system prevents an erroneous operation
 on 500 and 1000 Volt ranges
• Safety standard IEC 61010-01 CAT III 600V
(Photo: 3021)
  • 50V 100V 250V 500V DCACV Resistance Continuitybuzzer Backlight AutoPowerOff
 

Insulation resistance

Test voltage 50/100/250/500V
Measuring range
(Auto range)
4.000/40.00/200.0MΩ (50/100V)
4.000/40.00/400.0/2000MΩ (250/500V)
First effective measuring range 0.1 - 20MΩ (50/100V)
0.1 - 40MΩ (250V)
0.1 - 200MΩ (500V)
Mid-scale value 5MΩ (50/100/250V)
50MΩ (500V)
Accuracy ±2%rdg±6dgt
Second effective measuring range lower 0 - 0.099MΩ
Second effective measuring range upper 20.01 - 200.0MΩ (50/100V)
40.01 - 2000MΩ (250V)
200.1 - 2000MΩ (500V)
Accuracy ±5%rdg±6dgt
Rated current DC 1 - 1.2mA
Output short circuit current 1.5mA max

Ω/Continuity

Auto range 40.00/400.0Ω
Accuracy ±2%rdg±8dgt
Output voltage on open circuit 5V±20%
Output short circuit current DC 220±20mA
Fuse Quick acting ceramic fuse 0.5A/600V (Ø6.35×32mm)

AC Voltage

AC voltage range AC 20 - 600V (50/60Hz)
DC -20 - -600V/+20 - +600V
Accuracy ±3%rdg±6dgt

General

Applicable standards IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)
Power source R6 × 6 or LR6 × 6
Dimensions / Weight 105(L) × 158(W) × 70(D)mm / 600g approx.
Included Accessories 7150A (Remote control switch set),
9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual
Optional Accessories 7115 (Extension Probe), 8016 (Hook type prod),
8923 (Fuse [0.5A/600V]), 9089 (Carrying Case)

 

206786