Home  //  Products  //  Clamp Meters  //  MODEL 2608A  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

MODEL 2608A

AC Analogue Clamp Meters

MODEL 2608A

 

MODEL 2608A
CE
 
• DC voltage range is also available especially for checking emergency battery operated power supply.
• Can measure temperature using optional probe.
• Tear drop shaped transformer jaws for ease of use.

φ33 MAX300A Temperature ACA DCACV Resistance DATAHOLD

 

 

AC A 6/15/60/150/300A ±3% of FS
AC V 150/300/600V ±3% of FS
DC V 60V ±3% of FS
Ω 1/10kΩ (25/250Ω mid-scale)
±2% of scale length
Temperature -20ºC - +150ºC (with the use of Temperature Probe 7060)
±5ºC (0ºC - +100ºC)
±10ºC (other ranges)
Conductor size Ø33mm max.
Frequency response 50Hz/60Hz
Applicable standards IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61010-2-032
Power source R6 (AA) (1.5V) × 1
Dimensions 193(L) × 78(W) × 39(D)mm
Weight 275g approx.
Included Accessories 7066A (Test leads)
8923 (Fuse [0.5A/600V]) × 2
9097 (Carrying case)
R6 (AA) × 1
Instruction Manual
Optional Accessories 7060 (Temperature probe)
8008 (Multi-Tran)

 

About Kyoritsu

Quality Control Concept

Kyoritsu started early an effort to establish system that ensures traceability to the national standards in order to produce reliable instruments as well as instruments that can assure reliability of other equipment and installations.

When traceability is in place, measurements taken with an instrument any time and anywhere in any situation can be related to the appropriate national measurement standards through a clear and unbroken chain of comparisons.

For example, in terms on measurement defined by JIS (Japanese Industrial Standards), traceability is specified as a condition in which a calibration path is established from instruments produced or in-house standards to higher level standards to the national standards. Kyoritsu currently has a system in place as shown in the figure below.

Our calibrator (standard) is calibrated at Japan Electric Meters Inspection Corporation (JEMIC), Japan Quality Assurance Organization (JQA) and Fluke Japan who perform calibration based on the units established and maintained by National Institute of Advanced Industrial Science and Technology (AIST). The standard is used as the in-house standard to calibrate all the test and measuring equipments which are used in-house. 

Voltage :
Precision calibrators are used as in-house DC and AC voltage standards.
Current :
DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance :
Calibration resisters are calibrated with a DC standard current generator and the precision digital multimeter.

Calibration System for Electrical Measuring Instruments

ISO9001 QUALITY STANDARDS APPROVAL

Ehime Factory of Kyoritsu Electrical Instruments Works, Ltd. obtained ISO 9001 certification in December, 1992. The certification was given by Bureau Veritas which is one of the globally recognized certification bodies. International Quality Management Standards Approval

Authenticated Sites
Headquarters*Ehime Factory*R&D Center*Osaka Office

 

KEW 2200

AC Digital Clamp Meters

KEW 2200

 

KEW 2200
CE
 
• Ultra Slim and lightweight Handy design
• 1000A AC Clamp Meter AC40/400/1000A Auto Range
• Ø33mm Tear Drop Jaw easy to use in tight places
• DMM function ACV, DCV, Ω, Continuity Buzzer
• Fuseless electronic protection on up Ω/ to 600V
• IEC61010-1 Safety Standard
CAT III 600V (AC A) CAT III 300V / CAT II 600V (AC/DC V)

φ33 MAX1000A ACA DCACV Resistance Continuitybuzzer DATAHOLD AutoPowerOff

Ultra Slim and lightweight Handy design / Current DMM function

 

AC A 40.00/400.0/1000A (Auto-ranging)
±1.4%rdg±6dgt (50/60Hz)
±1.6%rdg±6dgt (45 - 65Hz)
AC V 4.000/40.00/400.0/600V (Auto-ranging)
±1.8%rdg±7dgt (45 - 65Hz)
±2.3%rdg±8dgt (65 - 500Hz)
DC V 400.0mV/4.000/40.00/400.0/600V (Auto-ranging)
±1.0%rdg±3dgt (*1)
Ω 400.0Ω/4.000/40.00/400.0kΩ/4.000/40.00MΩ (Auto-ranging)
±2.0%rdg±4dgt (0 - 400kΩ)
±4.0%rdg±4dgt (4MΩ)
±8.0%rdg±4dgt (40MΩ)
Continuity buzzer buzzer sounds below 50±30Ω
Conductor size Ø33mm max.
Applicable standards IEC 61010-1
CAT III 600V Pollution degree 2 (AC A),
CAT III 300V / CAT II 600V Pollution degree 2 (AC/DC V)
IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC)
Power source R03/LR03 (AAA) (1.5V) × 2
*continuous measuring time:
approx. 350 hours (Auto power off: approx. 10 minutes)
Dimensions 190(L) × 68(W) × 20(D)mm
Weight Approx. 120g (including batteries)
Included Accessories 7107A (Test leads), 9160 (Carrying case), R03 (AAA) × 2,
Instruction Manual
Optional Accessories 8008 (Multi-Tran)

 

KEW 2210R

AC Digital Clamp Meters

KEW 2210R

 

KEW 2210R
CE
 
• Flexible and light weight clamp sensor
• Wide reading range up to 3000A
• True RMS
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V / CAT III 1000V)

TRUE RMS CAT4 600V φ150 MAX3000A ACA Backlight DATAHOLD MAX/MIN AutoPowerOff

AC A (RMS)
 Range 30.00/300.0/3000A
Accuracy ±3%rdg±5dgt[45-500Hz]
(At the center of the circle formed by the flexible sensor)
Crest factor
(CF)
Full scale CF<1.6, half scale<3.2
Effective input crest values are √2 times of the max values of each range.
Conductor size φ150mm max.
Influence of
Conductor position
Additional ±3% (max.) depending on the distance from the center position
Overload protection 5000A AC for 10 seconds
Applicable standards IEC 61010-1, IEC 61010-2-032
CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree 2
IEC 61326-1(EMC) , IEC 60529 IP40 , EN50581(RoHS)
Operating temperature
& humidity
0 - +50℃,less than 80% RH (without condensation)
Storage temperature
& humidity
-10 - +60℃,less than 70% RH (without condensation)
Power source R03 / LR03(AAA)(1.5V)×2
※Continuous measuring time:approx.120hours
(Auto power off:approx.15 minutes)
Dimensions 120(L)×70(W)×26(D):Display unit
φ8.5mm approx.:Cable diameter
1.8m approx.:Cable length
Weight 300g approx. (including batteries)
Included Accessories 9174 (Carrying case)
LR03(AAA)×2, Insruction manual

 

KEW 2040

AC Digital Clamp Meters

KEW 2040

 

KEW 2040
CE
 
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.
• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.
• Thus, very useful for power distribution companies, power utilities and maintenance fields.

CAT4 600V φ33 MAX600A ACA DCACV Resistance Continuitybuzzer Frequency DUTYMAX/MIN Relative AutoPowerSave

 

 

 

AC A 0 - 600.0A
±1.5%rdg±5dgt (50/60Hz)
±3.5%rdg±8dgt (40 - 400Hz)
AC V 6/60/600V
Auto Ranging
±1.3%rdg±4dgt (50/60Hz)
±3.0%rdg±5dgt (40 - 400Hz)
DC V 600m/6/60/600V
Auto Ranging
±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)
±1%rdg±5dgt (600 - 6M) / ±5%rdg±8dgt (60M)
Continuity buzzer Buzzer Sounds at 100Ω
Frequency/DUTY 10/100/1k/10kHz (Auto Ranging) / 0.1 - 99.9%
Conductor size Ø33mm
Applicable standards IEC 61010-1 CAT IV 600V,
IEC 61010-031,
IEC 61010-2-032,
IEC 61326
Power source R03 (1.5V) (AAA) × 2
Dimensions 243(L) × 77(W) × 36(D)mm
Weight 300g
Included Accessories 7066A (Test leads)
9094 (Carrying case)
Instruction Manual
Optional Accessories 8008 (Multi-Tran)