KEW 6010B

Jual Multi Function Testers KEW 6010B

 

Multi Function Testers

KEW 6010B

KEW 6010B
CE
 
• Continuity:20/200Ω 200mA Test Current
• Insulation: 500/1000V, 20/200MΩ 1mA Rated Test Current
• Loop Impedance:20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)
• RCD:10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
• Test of a large kind of RCD's:Standard, Selective, AC and A(DC sensitive breakers)
• Uc(Contact Voltage): 100V
• Designed to IEC 61010-1, IEC 61557
• Data Memory:300 measured results
• The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.
 
Continuity Testing
Measuring Range 20/200Ω (Auto-Ranging)
Open Circuit Voltage > 6V
Short Circuit Current > 200mA
Accuracy ±(3%rdg + 3dgt)
Insulation Resistance Testing
Measuring Range 20/200MΩ (Auto-Ranging)
Test Voltage 500/1000V
Open Circuit Voltage +20% - 0%
Rated Current > 1mA
Accuracy ± (3%rdg + 3dgt)
Loop Impedance Testing
Impedance Range 20/2000Ω
Rated Voltage 230V + 10% - 15%(50Hz)
Normal Test Current 20Ω:25A/10ms
2000Ω:15mA/350ms max.
Accuracy ±(3%rdg + 8dgt)
RCD Testing
Test Current
(Test Current Duration)
x1/2, x1 10, 30, 100, 300, 500mA (2000ms)
Fast 150mA (50ms)
DC 10, 30, 100, 300mA (2000ms), 500mA (200ms)
Auto Ramp Goes up by 10% from 20% to 110% of IΔn. 300ms×10
Rated Voltage 230V + 10% - 15% 50Hz
AccuracyTest Current x1/2: -8%-2%
x1, FAST: +2%+8%
DC: ±10%
Auto Ramp: ±4%
Trip Time ±(1%rdg + 3dgt)
Uc Testing
Measuring Range 100V
Rated Voltage 230V + 10% - 15% (50Hz)
Test Current 5mA at IΔn = 10mA
15mA at IΔn = 30/100mA
150mA at IΔn = 300/500mA
Accuracy +5%+15%rdg, ±8dgt
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)
Power source R6 or LR6 × 8
Dimensions 175(L) × 115(W) × 86(D)mm
Weight 840g approx.
Included Accessories 7122B (Test leads)
KAMP10* (Test Lead with IEC Connector)
Pouch for Test leads
Shoulder Strap
Shoulder Pad
Instruction Manual
Optional Accessories 7133B (Distribution board test leads)
8212-RS232C (RS232C adaptor with "KEW Report (Software)")
8212-USB (USB adaptor with "KEW Report (Software)")

 

MODEL 6010A

Jual Multi Function Testers MODEL 6010A

 

Multi Function Testers

MODEL 6010A

MODEL 6010A
CE
 
Continuity and Insulation Testing
• Live circuit warning LED:
Immediate illumination of a warning lamp if the circuit under test is live
• Auto Discharge:
Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing
• Integral overload protection on internal continuity and insulation test circuitry
• Autoranging
• 500V DC test voltage for insulation tests
• 200mA short circuit current on continuity ranges

Loop and RCD Testing
• Wiring connection check LED’s:
Immediate indication if wiring of circuit under test is correct
• Overheat Protection:
Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement
• Supply Voltage Indication:
Can display supply voltage value in loop impedance mode
• Low Current Loop Impedance Test:
Short duration low test current will prevent tripping of many passive RCDs
• Auto Data Hold:
Retains displayed reading for set period following test
• Phase Angle Selection:
Selection of test current from +ve or -ve half cycle of waveform can prevent tripping of polarized type RCDs
 
Continuity Testing
Measuring Ranges 0 - 19.99 and 10.0 - 199.9Ω (2 auto ranges)
Open Circuit Voltage > 4V (as per IEC 364)
Short Circuit Current > 200mA DC (as per IEC 364)
Accuracy ±(3% + 3dgt)
Loop Impedance Testing
Rated Voltage 230V AC +10%-15% (50Hz)
Voltage Measuring Range 100-250V AC (50Hz)
Impedance Range
Nominal Test Current
20/2000Ω
25A (20Ω range) 15mA (2000Ω range)
Test Period 1/2 cycle (10ms)
Accuracy 20Ω range : ±(3% + 8dgt)   2000Ω range : ±(3% + 8dgt)
Insulation Testing
Measuring Ranges 0 - 19.99 and 10.0 - 199.9MΩ (2 auto ranges)
Test Voltage 500V DC
Output Voltage on
Open Circuit
570V DC±6%
Rated Current > 1mA (as per IEC 364)
Accuracy ± (3% + 3dgt)
RCD Testing
Rated Voltage 230V AC +10%-15% (50Hz)
Trip Current Settings RCD × 1/2: 5, 15, 50, 150, 250mA
RCD × 1: 10, 30, 100, 300, 500mA
Trip Current Duration RCD × 1/2 × 1: 2000ms
Fast Trip 150mA
Accuracy Trip current ±3% of test current at 230V.
Trip time ±(3% + 3dgt)
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61557
Power source R6 (AA) (1.5V) × 8
Dimensions 175(L) × 115(W) × 86(D)mm
Weight 780g approx.
Included Accessories 7122B (Test leads)
KAMP10* (Test Lead with IEC Connector)
Pouch for Test leads
Shoulder Strap
Shoulder Pad
R6 (AA) × 8
Instruction Manual
Optional Accessories 7133B (Distribution board test leads)

 

KEW 6315

Jual

Power Quality Analyzer

KEW 6315NEW

KEW 6315
CE
 
• Simultaneous Power & Power quality measurements
• Helpful support functions
• Measurement with high accuracy
• Remote monitoring on PC and Android device
• Various Clamp Current Sensors
• Energy consumption check on site
• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V
  • TRUE RMS USB Bluetooth External
  • Simultaneous Power & Power quality measurements
    • Power/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch) 
  • Helpful support functions
    • Quick Start Guide, Wiring check and Sensor detection for easy and reliable measurement
  • Measurement with high accuracy
    • Guaranteed accuracy:±0.3%rdg (energy),±0.2%rdg (voltage/ current)
      Complies with the International Standard IEC 61000-4-30 Class S and the European Standard EN50160
  • Remote monitoring on PC and Android device
    • Remote checking of measurement in real-time is possible via Bluetooth communication.
    • Recorded data can be saved in the supplied SD card.
    • EN50160 report can be generated after survey by PC software.
  • Various Clamp Current Sensors
    • Various types of clamp and flexible sensors are available:
      from 1000mA Range up to 3000A Range and Earth leakage measurements
    • Energy consumption check on site
      Trend and demand graphs for easy recognition.
      TFT color display with high resolution.
  • IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V

Free Android software "KEW smart 6315" is available on "Google Play Store"

•Supporting Android ver. 2.2 - 4.4
•WVGA (800 × 480) resolution or higher

Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.

Power Quality Analyzer

Wiring connections 1P2W, 1P3W, 3P3W, 3P4W
Measurements and parameters Voltage, Current, Frequency, Active power, Reactive power, Apparent power,Active energy, Reactive energy, Apparent energy, Power factor (cos θ),
Neutral current, Demand, Harmonics, Quality (Swell/Dip/Interruption, Transients/Over voltage, Inrush current, Unbalance rate),
Capacitance calculation for PF correction unit, Flicker
Voltage (RMS)  
 Range 600.0 / 1000V
Accuracy ±0.2%rdg±0.2%f.s. (sine wave, 40 - 70Hz)
Allowable input 1 - 120% of each range (rms). 200% of each range (peak)
Display range 0.15 - 130% of each range
Crest factor 3 or less
Sampling speed of Voltage transient 24µs
Current (RMS)  
 Range 8128 ( 50A type ) : 5 / 50A / AUTO
8127 ( 100A type ) : 10 / 100A / AUTO
8126 ( 200A type ) : 20 / 200A / AUTO
8125 ( 500A type ) : 50 / 500A / AUTO
8124/8130 ( 1000A type ) : 100 / 1000A / AUTO
8146/8147/8148 ( 10A type ) : 1 / 10A / AUTO
8129 ( 3000A type ) : 300 / 1000 / 3000
Accuracy ±0.2%rdg±0.2%f.s. + accuracy of clamp sensor (sine wave, 40 - 70Hz)
Allowable input 1 - 110% of each range (rms). 200% of each range (peak)
Display range 0.15 - 130% of each range
Crest factor 3 or less
Active power  
 Accuracy ±0.3%rdg±0.2%f.s. + accuracy of clamp sensor
(power factor 1, sine wave, 40 - 70Hz)
Influence of power factor ±1.0%rdg (reading at power factor 0.5 against power factor 1)
Frequency meter range 40 - 70Hz
Power supply (AC Line) AC100 - 240V / 50 - 60Hz / 7VA max
Power supply (DC battery) Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6
Battery life approx. 3h (LR6, Backlight OFF)
Internal memory FLASH memory (4MB)
PC card interface SD card (2GB)
PC communication interface USB Ver2.0, Bluetooth Ver2.1 + EDR Class2
Display 320 × 240 (RGB) Pixel, 3.5inch color TFT display
Display update period 1 sec

 

General

Applicable standards IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V Pollution degree 2
IEC 61010-2-030, IEC 61010-031, IEC 61326, EN 50160
IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7
Temperature and humidity range 23±5ºC, less than 85% RH (without condensation)
Operating temperature & humidity range 0 - +45ºC, less than 85% RH (without condensation)
Storage temperature & humidity range -20 - +60ºC, less than 85% RH (without condensation)
Power supply (AC Line) AC100 - 240V / 50 - 60Hz / 7VA max
Power supply (DC battery) Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6
Battery life approx. 3h (LR6, Backlight OFF)
Dimensions 175(L) × 120(W) × 68(D) mm
Weight Approx. 900g
Included Accessories 7141B (Voltage test lead)
7170 (Power cord)
7219 (USB cable)
8326-02 (SD card 2GB)
9125 (Carrying case for KEW 6315)
9135 (Carrying case for KEW 6315-03)
Input terminal plate × 6, KEW Windows for KEW 6315 (software),
Quick manual, Alkaline size AA battery (LR6) × 6
Optional Accessories 8124, 8125, 8126, 8127, 8128 (Load current clamp sensor)
8129, 8130 (Flexible clamp sensor)
8146, 8147, 8148 (Leakage and Load current clamp sensor)
8312 (Power supply adaptor)
9132 (Magnetci carrying case)

 

Multi Function Testers

Jual Multi Function Testers Kyoritsu

Multi Function Testers

  • MODEL 6010A

    MODEL 6010A

    Continuity and Insulation Testing
    • Live circuit warning LED:
    Immediate illumination of a warning lamp if the circuit under test is live
    • Auto Discharge:
    Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing
    • Integral overload protection on internal continuity and insulation test circuitry
    • Autoranging
    • 500V DC test voltage for insulation tests
    • 200mA short circuit current on continuity ranges

    Loop and RCD Testing
    • Wiring connection check LED's:
    Immediate indication if wiring of circuit under test is correct
    • Overheat Protection:
    Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement
    • Supply Voltage Indication:
    Can display supply voltage value in loop impedance mode
    • Low Current Loop Impedance Test:
    Short duration low test current will prevent tripping of many passive RCDs
    • Auto Data Hold:
    Retains displayed reading for set period following test
    • Phase Angle Selection:
    Selection of test current from +ve or -ve half cycle of waveform can prevent tripping of polarized type RCDs

    • KEW 6010B

      KEW 6010B

      • Continuity: 20/200Ω, 200mA Test Current
      • Insulation: 500/1000V, 20/200MΩ, 1mA Rated Test Current
      • Loop Impedance: 20/2000Ω, 15mA Test Current at 2000Ω (No RCD Trip)
      • RCD: 10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
      • Test of a large kind of RCD's:
      Standard, Selective, AC and A (DC sensitive breakers)
      • Uc (Contact Voltage): 100V
      • Designed to IEC 61010-1, IEC 61557
      • Data Memory: 300 measured results
      • The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

      • MODEL 6011A

        MODEL 6011A

        • Complies with IEC 61557
        • Designed to IP 54 Rating
        • Live circuit and wiring connection check LED's
        • Triple ranges insulation tests at 250, 500 and 1000V
        • Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range (No RCD Trip)
        • Phase angle selection on RCD ranges
        • Polarity switch for continuity tests
        • Auto-null facility for continuity tests
        • Earth probe for loop impedance testing on extraneous metalwork
        • Contact Voltage Reading
        • Test of a large kind of RCD's:
        Standard, Selective, AC and A (DC sensitive breakers)

        • KEW 6016

          KEW 6016

          The KEW 6016 Multi-Function tester performs 10 functions
          in one instrument.

          • Continuity tester
          • Insulation resistance tester
          • Loop impedance tester
          • PSC tester
          • PFC tester
          • RCD tester
          • Earth tester
          • Phase rotation tester
          • Voltage measurement
          • Frequency measurement

          • MODEL 6018

            MODEL 6018

            • Designed to meet IEC 61010-1 CAT III 600V
            • Test leads with remote control switch.
            (For insulation&Simplified Earth Test)
            • Back light function.
            • Color coded scales and range switch position for easy reading.
            • Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
            • Can be hung around the neck for both hand’s operation.

PV Insulation Earth Tester

KEW 6024PV

KEW 6024PVNEW

• Correct measuring for Insulation resistance even if the panel is under generating power
• Waterproof design: Can measure under the bad weather condition
• Memory function up to 1000 data
• Luminescence button and Backlight

  • Backlight USB AutoPowerOff

Jual Loggers KEW 5020

Jual Loggers KEW 5020

 

Loggers

KEW 5020

KEW 5020
CE
3 channel inputs for the simultaneous recording of Leakage Current , Load Current and Voltage
• Power Quality analysis
• Large capacity for storing 60,000 data points
• Lowpass Filter will filter out the harmonics
• LED flickers when the preset current/voltage value is exceeded
• CALL:Confirmation of recorded data
• Selection of One-time mode or Endless mode
• Non Volatile Memory
• Battery power indicator
• The userfriendly PC software "KEW LOG Soft 2" is supplied
• Continuous measuring time:Approx. 10 days (Alkaline Battery)
  • TRUE RMS USB External

  • 3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
  • Large Capacity for storing 60,000 data points
    • 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded
  • Lowpass Filter will filter out the harmonics (Cutoff Frequency = Approx. 160Hz)
  • LED flickers when the preset current / voltage value is exceeded
  • CALL: Confirmation of recorded data
    • The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)
    • RECALL: The last 10 recorded data points including time/date can be recalled on the logger display
  • Selection of One-time mode or Endless mode
    • One-time on: Recording will stop when memory is used up
    • One-time off: Overwrite the old data, and store the latest data
  • Non Volatile Memory
    Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)
  • Battery power indicator
    Indicates battery voltage in 4-levels
    (It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)
  • The userfriendly PC software "KEW LOG Soft 2" is supplied
    • Supplied with the user friendly software "KEW LOG Soft 2". This permits editing, analysis and graphical display of data.
    • The recorded data is downloadable onto a PC via USB cable.
    • Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor. (only on KEW 5020)
    • Simplified Power Integration
      (The "KEW LOG Soft 2" uses current and voltage recorded to calculate the integral power consumption)
  • Continuous measuring time: Approx. 10 days (Alkaline Battery)

Normal Recording Mode
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)

RangeRMS Accuracy
100.0mA ±2.0%rdg±0.9%f.s.+ Accuracy of Sensor
Other ranges ±1.5%rdg±0.7%f.s.+ Accuracy of Sensor
Crest Factor 2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.

*Max, Min and Instant Peak values in Normal Recording mode are just reference values:
their accuracies aren't guaranteed.

Trigger Recording Mode (AC 50/60Hz sine wave)

RangeAccuracy
100.0mA ±3.5%rdg±2.2%f.s.+ Accuracy of Sensor
Other ranges ±3.0%rdg±2.0%f.s.+ Accuracy of Sensor

Capture Recording Mode

RangeAccuracy
100.0mA ±3.0%rdg±1.7%f.s.+ Accuracy of Sensor
Other ranges ±2.5%rdg±1.5%f.s.+ Accuracy of Sensor
Recording mode Normal, Trigger, Capture, Power Quality Analysis
Operating system Successive Approximation
(CH1 single synchronized sampling)
Rated max. working voltage AC 9.9Vrms, 14V peak value
Number of input channel 3ch
Measuring method True RMS
RMS measuring interval approx. 100ms
Sampling interval Normal/Trigger mode : approx. 1.65ms/CH
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)
P.Q.A. mode : approx. 0.55ms
Low battery warning Battery mark display (in 4 levels)
Over-range indication "OL" mark is displayed when exceeding the measuring range
Auto power off Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)
Possible measurement time Approx. 10 days (with alkaline LR6 batteries)
Applicable standards IEC 61010-1:2001 CAT III 300V Pollution degree2
IEC 61326 (EMC standard)
Dimensions 111(L)×60(W)×42(D)mm
Weight Approx. 265g
Included Accessories Alkaline battery LR6×4pcs, 9118 (Carrying case)
PC software "KEW LOG Soft 2", 7148 (USB cable)
Instruction manual, Quick manual, Install manual,
USB Notice sheet
Optional Accessories 8146/8147/8148 (Leakage & Load current Clamp Sensor),
8121/8122/8123 (Load current Clamp Sensor),
8129/8130 (Flexible Clamp Sensor),
8309 (Voltage Sensor: only KEW 5020), 8320 (AC Adapter),
9135 (Carrying bag), 9119 (Hard carry case),
7185 (Extension cable for sensor)

 