Home  //  Products  //  Clamp Meters  //  MODEL 2608A  //  Kyoritsu Indonesia
  • Email us at : sales@kyoritsuindonesia.com

KEW 3126

Jual High Voltage Insulation Testers KEW 3126

 

High Voltage Insulation Testers

KEW 3126

KEW 3126
CE AutoDischarge
 
• Short-Circuit Current up to 5mA
• Wide range measurements from 500V to 5000V and up to 1TΩ
• Large digital display with Bar Graph indication and white LED back light
• Polarization Index measurement (PI), Dielectric Absorption Ratio (DAR)
• Filter function reduces noise interference for obtaining stable measurement
• Indication of Output voltage and Discharge voltage
• Auto-discharge function and Output voltage warning function
• Auto power off and Battery Indicator
• Safety standard IEC 61010-1 CAT III 600V
  • CAT3 600V DCACV Backlight AutoPowerOff 500V 1000V 2500V 5000V
 

Insulation resistance

Range 500V 1000V 2500V 5000V
Accuracy 0.0 - 99.9MΩ
100 - 999MΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 1.99GΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 9.99GΩ
10.0 - 99.9GΩ
0.0 - 99.9MΩ
100 - 999MΩ
1.00 - 9.99GΩ
10.0 - 99.9GΩ
100 - 1000GΩ
(1TΩ)
±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt
±20%rdg
(100GΩ or more)
Short circuit current Max. 5mA
Rated test Current 1mA to 1.2mA
at 0.5MΩ load
1mA to 1.2mA
at 1MΩ load
1mA to 1.2mA
at 2.5MΩ load
1mA to 1.2mA
at 5MΩ load
Open circuit voltage 500VDC
+30%
-0%
1000VDC
+20%
-0%
2500VDC
+20%
-0%
5000VDC
+20%
-0%
Maximum display 999 Counts (1000 counts only at 1000GΩ)
Current consumption 1000mA approx. (During measurement)

Voltage measurement

Measuring range 30 - 600V AC/DC (50/60Hz)
Accuracy ±2%rdg±3dgt

Insulation resistance

Test voltage 500/1000/2500/5000V
Measuring ranges 0.0 - 99.9MΩ, 100 - 999MΩ (500V)
0.0 - 99.9MΩ, 100 - 999MΩ, 1.00 - 1.99GΩ (1000V)
0.0 - 99.9MΩ, 100 - 999MΩ, 1.00 - 9.99GΩ, 10.0 - 99.9GΩ (2500V)
0.0 - 99.9MΩ, 100 - 999MΩ, 1.00 - 9.99GΩ, 10.0 - 99.9GΩ, 100 - 1000GΩ (1TΩ) (5000V)
Accuracy ±5%rdg±3dgt (500/1000/2500V)
±5%rdg±3dgt, ±20%(100GΩ or more) (5000V)
Short circuit current Max. 5mA
Rated test current 1mA to 1.2mA at 0.5MΩ load (500V)
1mA to 1.2mA at 1MΩ load (1000V)
1mA to 1.2mA at 2.5MΩ load (2500V)
1mA to 1.2mA at 5MΩ load (5000V)
Open circuit voltage 500VDC+30%, -0% (500V)
1000VDC+20%, -0% (1000V)
2500VDC+20%, -0% (2500V)
5000VDC+20%, -0% (5000V)
Maximum display 999 Counts (1000 counts only at 1000GΩ)
Current consumption 1000mA approx. (During measurement)

Voltage measurement

Measuring ranges 30 - 600V
AC/DC
(50/60Hz)
Accuracy ±2%rdg
±3dgt
Maximum display 630 Counts
Current consumption 110mA approx.

General

Applicable standards IEC 61010-1 CAT III 600V Pollution degree 2
IEC 61010-031, IEC 61326
Power source DC12V : LR14×8 pcs.
Dimensions 205(L) × 152(W) × 94(D)mm
Weight 1.8kg approx.
Included Accessories 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord)
8019 (Hook type prod), 9159 (Hard case)
LR14 (Alkaline battery size C) × 8, Instruction manual
Optional Accessories 7168A (Line probe with alligator clip)
7253 (Longer Line probe with alligator clip)
8302 (Adaptor for recorder)

 

MODEL 3124

Jual High Voltage Insulation Testers MODEL 3124

 

High Voltage Insulation Testers

MODEL 3124

MODEL 3124
AutoDischarge
 
• Permits a wide range of insulation testing up to 100GΩ at variable test voltage from 1kV to 10kV.
• DC voltage output for recorders.
• Output voltage is shown on the digital display.
• After tests, automatically discharges the charges stored in the circuit under test.
• Operated by rechargeable Nickel-Cadmium batteries.
  • 1KV~10KV External
 

Insulation Resistance

DC Test Voltage 1k - 10kV variable / 1000V
Measuring ranges
(automatic change)
1.6GΩ/100GΩ (autoranging) (1k - 10kV variable)
100MΩ (1000V)
First effective measuring range 0.05 - 50GΩ (1k - 10kV variable)
1 - 100MΩ (1000V)
Accuracy ±10% rdg
Other ranges accuracy ±1% of scale length
Output voltage and set voltage indicate DC 0 - 10kV
±2%rdg±2dgt

General

Power source Ni-Cd rechargeable battery (1.2V) × 8
Dimensions 200(L) × 140(W) × 80(D)mm
Weight 1.5kg approx.
Included Accessories 7082 (Lead for recorder)
7083 (Lead for battery charging)
7084 (Earth and guard leads)
8075 (120V) or 8080 (220V) (Battery charger)
9176 (Carrying case [Hard])
Ni-Cd rechargeable battery × 8
Instruction Manual

 

KEW 3127

Jual High Voltage Insulation Testers KEW 3127

High Voltage Insulation Testers

KEW 3127 NEW

 

KEW 3127
CE AutoDischarge
 
• Insulation Resistance up to 10TΩ
• Short-Circuit Current up to 5mA
• Wide Test Voltage from 250V to 5000V
• Diagnostic Insulation Tests: IR, PI, DAR, DD, SV, RAMP (Breakdown and Burn modes), Capacitance, Leakage Current
• Wireless communication by Bluetooth for transferring and showing real-time data to PC and Android device
• Memory and Logging functions
• Filter function reduces noise interference for obtaining stable measurements
• Large back light display with Bar-Graph indication
• Robust design for field use with IP65 (lid closed)
• Powered by rechargeable battery
• Safety Standard IEC 61010-1 CAT Ⅳ 600V

 

  • CAT4 600V DCACV Backlight USB AutoPowerOff Bluetooth 250V 500V 1000V 2500V 5000V

 

Free Android software "KEW smart 3127"
is available on "Google Play Store"(*)

<System requirement>
• Supporting Android ver. 2.2 - 4.4
• WVGA (800 × 480) resolution or higher

(*)Please search "KEW Smart" in Google Play Store.
Communication charge may be incurred separately to download application.

 

Insulation resistance

Test voltage 250V (*1) 500V 1000V 2500V 5000V
Max
measurement
value
9.99GΩ 99.9GΩ 199GΩ 999GΩ 9.99TΩ
Accuracy 0.0 - 99.9MΩ
±5%rdg±3dgt
0.0 - 999MΩ
±5%rdg±3dgt
0.0 - 1.99GΩ
±5%rdg±3dgt
0.0 - 99.9GΩ
±5%rdg±3dgt
0.0 - 99.9GΩ
±5%rdg±3dgt
0.1G - 9.99GΩ
±20%rdg
1G - 99.9GΩ
±20%rdg
2G - 199GΩ
±20%rdg
100G - 999GΩ
±20%rdg
0.1T - 9.99TΩ
±20%rdg
Short circuit current Max 5.0mA
Output
voltage
   
Accuracy -10 - +10% -10 - +20% 0 - +20%
Variable - -20% - 0% (5% step)
Monitor ±10%rdg±20V

Voltage measurement

Measuring range AC: 30 - 600V (50/60Hz), DC: ±30 - ±600V
Accuracy ±2%rdg±3dgt

Current measurement

Measuring range 0.00nA - 5.50mA
Accuracy ±10%rdg (*2)

Capacitance measurement

Measuring range 5.0nF - 50.0µF, 5.0nF - 25.0µF (5000V)
Accuracy ±5%rdg±5dgt

 

General

 

Applicable standards IEC 61010-1, 61010-2-030 CAT Ⅳ 600V Pollution degree 2,
IEC 61010-031, IEC 61326-1, 2-2
Power source Rechargeable Battery (Lead-acid Battery) 12V (*3)
Charging power: DC 15VA MAX
communication interface Bluetooth: Ver2.1 + EDR Class2, USB: Ver1.1
Dimensions 208 (L) × 225 (W) × 130 (D) mm
380 (L) × 430 (W) × 154 (D) mm (Hard case)
Weight 3127: 4kg Approx. (including battery),
Total: 8kg Approx. (including Accessories)
Included Accessories 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord),
8019 (Hook type prod), 8327EU (Power adaptor 15V/1A), 9171 (Hard case),
Instruction manual
Optional Accessories 7168A (Line probe with alligator clip: 3m),
7253 (Longer line probe with alligator clip: 15m),
8258 (USB communication set),
8302 (Adaptor for recorder 1mV/1µA)

 

KEW 3123A

Jual High Voltage Insulation Testers KEW 3123A

 

High Voltage Insulation Testers

KEW 3123A

KEW 3123A
 
• Rugged design with a hard carrying case for field use
• Detachable High Voltage Line probe
• Automatic ranges, high and low scales, indicated by different LED's
• Drip proof
  • 5000V 10KV
 

Insulation Resistance

DC Test Voltage 5000/10000V
Measuring ranges
(automatic change)
5GΩ/200GΩ (Auto-ranging) (5000V)
10GΩ/400GΩ (Auto-ranging) (10000V)
First effective measuring range 0.2 - 100GΩ (5000V)
0.4 - 200GΩ (10000V)
Accuracy ± 5% rdg
Other ranges accuracy ±10% rdg or 0.5% of scale length

General

Power source R6 (AA) (1.5V) × 8
Dimensions 200 (L) × 140 (W) × 80 (D) mm
Weight approx. 1kg
Included Accessories 7165A (Line probe) (3m)
7224A (Earth cord) (1.5m)
7225A (Guard code) (1.5m)
8019 (Hook type prod)
9158 (Hard case)
R6 (AA) × 8
Instruction manual
Optional Accessories 7168A
(Line probe with aligator clip)
8324 (Adaptor for recorder)
7253 (Longer Line probe with alligator clip) (15m)

 

KEW 3125A

Jual High Voltage Insulation Testers KEW 3125A

High Voltage Insulation Testers

KEW 3125A

NEW

 

KEW 3125A
CE AutoDischarge
 
• Insulation Resistance up to 1TΩ
• Short-Circuit Current up to 1.5mA
• Wide Test Voltage from 250V to 5000V
• Diagnosis Function of PI and DAR
• Newly-designed alligator clip
• It comes with a tough hard case
• Filter function reduces noise interference for obtaining stable measurement
• Large display with Bar Graph indication and backlight
• Live voltage warning
• Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V

 

  • CAT4 300V CAT3 600V DCACV Backlight AutoPowerOff 250V 500V 1000V 2500V 5000V

 

 

 

Insulation resistance

Rated voltage 250V 500V 1000V 2500V 5000V
Accuracy 0.0 - 100.0MΩ  0.0 - 99.9MΩ
80 - 1000M Ω  
0.0 - 99.9MΩ 
80 - 999MΩ
0.80 - 2.00G  Ω
 0.0 - 99.9MΩ 
 80 - 999MΩ
 0.80 - 9.99GΩ 
 8.0 - 100.0GΩ
0.0 - 99.9MΩ
80 - 999MΩ
0.80 - 9.99GΩ
8.0 - 99.9GΩ
80 - 1000GΩ
±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt
±20%rdg
(100GΩ or more)
Short circuit current 1.5mA
Output voltage   
Accuracy ±10% -10 - +20% 0 - +20%
Monitor ±10%rdg±20V

Voltage measurement

Measuring range AC: 30 - 600V (50/60Hz), DC: ±30 - ±600V
Accuracy ±2%rdg±3dgt

 

General

 

Applicable standards IEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2,
IEC 61010-031, IEC 61326-1, 2-2
Power source DC12V : LR14/R14 × 8pcs
Dimensions 177 (L) × 226 (W) × 100 (D) mm
300 (L) × 315 (W) × 125 (D) mm (Hard case)
Weight 3125A: 1.9kg approx. (including batteries)
4kg approx. (including accessories)
Included Accessories 7165A (Line probe: 3m), 7264 (Earth cord: 3m), 7265 (Guard cord: 3m),
8019 (Hook type prod), 9180 (3025A Hard case), 9181 (3125A Hard case),
LR14 (Alkaline battery size C) × 8, Instruction manual
Optional Accessories 7168A (Line probe with alligator clip: 3m),
7253 (Longer line probe with alligator clip: 15m),
8302 (Adaptor for recorder)

 

206854
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
149
84
823
205067
2464
5007
206854

Your IP: 18.210.22.132
Server Time: 2019-10-19 08:24:58